Technical Data Sheet — L-BL2 2BL2061 IE3 vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Hoja de datos 2BL2 061: bomba de vacío de circuito compacta (serie L-BL2, 'Pump in a Box'), 3~ 50/60 Hz, IP55, clase de aislamiento F, UL (E489378). Código de pedido 2BL2061-1 □ K50-1B / K50-6B / Q50-7B con sustitución del rango de tensión (K, Q) y código de tensión (1, 6, 7).
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Pumping speed | 60 m³/h p.1 ↗ | 2BL2 061, 50 Hz |
| Pumping speed | 60 m³/h p.1 ↗ | 2BL2 061, 60 Hz |
| Motor power | 1,4 kW p.2 ↗ | 2BL2 061, 50 Hz, IE3 |
| Motor power | 1,8 kW p.2 ↗ | 2BL2 061, 60 Hz, IE3/NP |
| Voltage | 190-210 V p.2 ↗ | 50 Hz, Δ |
| Voltage | 190-210 / 380-420 V p.2 ↗ | 50 Hz, Δ / Y |
| Voltage | 220-240 / 380-420 V p.2 ↗ | 50 Hz, Δ / Y |
| Voltage | 380-420 / 660-725 V p.2 ↗ | 50 Hz, Δ / Y |
| Voltage | 500 V p.2 ↗ | 50 Hz, Y |
| Voltage | 220-240 / 440-480 V p.2 ↗ | 60 Hz, YY / Y |
| Voltage | 230 / 460 V p.2 ↗ | 60 Hz, YY / Y |
| Voltage | 575 V p.2 ↗ | 60 Hz, Y |
| Current | 8,7 A p.2 ↗ | 50 Hz, 190-210 V Δ |
| Current | 10,0 / 5,0 A p.2 ↗ | 50 Hz, 190-210 / 380-420 V |
| Current | 7,5 / 4,35 A p.2 ↗ | 50 Hz, 220-240 / 380-420 V |
| Current | 4,35 / 2,50 A p.2 ↗ | 50 Hz, 380-420 / 660-725 V |
| Current | 3,35 A p.2 ↗ | 50 Hz, 500 V Y |
| Current | 8,6 / 4,3 A p.2 ↗ | 60 Hz, 220-240 / 440-480 V |
| Current | 7,3 / 3,65 A p.2 ↗ | 60 Hz, 230 / 460 V |
| Current | 2,90 A p.2 ↗ | 60 Hz, 575 V Y |
| Service factor | 1,57 - p.2 ↗ | 50 Hz, 1,4 kW |
| Service factor | 1,42 - p.2 ↗ | 60 Hz, 1,8 kW |
| Noise level | 69 dB(A) p.2 ↗ | 50 Hz, 1,4 kW |
| Noise level | 73 dB(A) p.2 ↗ | 60 Hz, 1,8 kW |
| Weight | 64 kg p.2 ↗ | 50 Hz, 1,4 kW |
Operating Limits
- Protection class: IP55 p.1 ↗
- Insulation material class: F p.2 ↗
- Intake temperature for characteristic curves: 20 °C p.1 ↗
- Characteristic curve tolerance: ± 10 % p.1 ↗
- Noise measurement tolerance: ±3 dB(A) p.2 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-6 p.2 ↗ | 2BL2061 | Model range and size (L-BL2, size 061) |
| 7-8 p.2 ↗ | -1 | Design variant |
| field 1 (□) p.2 ↗ | K / Q | Voltage-range variant: K = 50 Hz 190-210 VΔ / 190-210 VYY / 220-240 VΔ / 380-420 VY, 60 Hz 220-240 VYY / 440-480 VY; Q = 50 Hz 475-525 VY / 475-525 VΔ / 400 VΔ / 690 VY, 60 Hz 550-600 VY / 550-600 VΔ / 460 VΔ |
| field 2 (□) p.2 ↗ | 1 / 6 / 7 | Voltage code: 1 = 190-210 VΔ (50 Hz) / 200 VΔ (60 Hz); 6 = 220-240 VΔ / 380-420 VY (50 Hz) / 220-240 VYY / 440-480 VY (60 Hz); 7 = 380-420 VΔ / 660-725 VY (50 Hz) / 460 VΔ (60 Hz) |
| suffix p.2 ↗ | K50-1B / K50-6B / Q50-7B | Complete ordering suffix combining voltage-range variant and voltage code |