Technical Data Sheet — 2BV3151 vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Familia de bombas de vacío de anillo líquido L-BV3, hoja de datos 2BV3 151 (Typ 2BV3 151). Abarca motores 1~ 50/60 Hz y 3~ 50/60 Hz, IP55, clase de aislamiento F, aprobados UL/CSA; materiales estándar bronce y acero inoxidable; variantes de tensión 100/200 V, 115/230 V, 185-240 D / 320-415 Y, 200-275 D / 345-480 Y, 190-210 D, 190-210 YY / 220-240 D / 380-420 Y.
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Ultimate inlet pressure | 33 mbar abs. p.1 ↗ | 2BV3 151, general |
| Cavitation-free operation down to | 80 mbar abs. p.1 ↗ | 2BV3 151, built-in cavitation protection |
| Rated voltage | 185-240 D / 320-415 Y V p.2 ↗ | 2BV3 151, 3~, 50 Hz |
| Rated voltage | 200-275 D / 345-480 Y V p.2 ↗ | 2BV3 151, 3~, 60 Hz |
| Rated voltage | 230 V p.2 ↗ | 2BV3 151, 1~, 50 Hz |
| Rated voltage | 230 V p.2 ↗ | 2BV3 151, 1~, 60 Hz |
| Current | 2,15 A p.2 ↗ | 2BV3 151, 1~, 50 Hz |
| Current | 2,4 A p.2 ↗ | 2BV3 151, 1~, 60 Hz |
| Current | 0,95 A p.2 ↗ | 2BV3 151, 3~, 50 Hz |
| Current | 0,84 A p.2 ↗ | 2BV3 151, 3~, 60 Hz |
| Power | 0,30 kW p.2 ↗ | 2BV3 151, 1~, 50 Hz |
| Power | 0,40 kW p.2 ↗ | 2BV3 151, 1~, 60 Hz |
| Power | 0,30 kW p.2 ↗ | 2BV3 151, 3~, 50 Hz |
| Power | 0,40 kW p.2 ↗ | 2BV3 151, 3~, 60 Hz |
| Service factor | 1,45 - p.2 ↗ | 2BV3 151, 1~, 50 Hz |
| Service factor | 1,25 - p.2 ↗ | 2BV3 151, 1~, 60 Hz |
| Service factor | 1,30 - p.2 ↗ | 2BV3 151, 3~, 50 Hz |
| Service factor | 1,30 - p.2 ↗ | 2BV3 151, 3~, 60 Hz |
| Quantity of operating liquid | 1,30 l/min p.2 ↗ | 2BV3 151, 50 Hz |
| Quantity of operating liquid | 1,30 l/min p.2 ↗ | 2BV3 151, 60 Hz |
| Sound pressure level | 55 dB(A) p.2 ↗ | 2BV3 151, 50 Hz |
| Sound pressure level | 62 dB(A) p.2 ↗ | 2BV3 151, 60 Hz |
| Weight | 10 kg p.2 ↗ | 2BV3 151, approx. |
| Protection rating | IP55 - p.1 ↗ | 2BV3 151, standard |
| Insulation material class | F - p.2 ↗ | 2BV3 151, standard |
Operating Limits
- Minimum inlet pressure (ultimate vacuum): 33 mbar abs. p.1 ↗
- Cavitation-free operation down to: 80 mbar abs. p.1 ↗
- Max. additional water carry over: 3,3 l/min p.2 ↗
- Max. back pressure: 1100 mbar p.2 ↗
- Protection rating: IP55 p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-4 p.2 ↗ | 2BV3 | Product family L-BV3 liquid ring vacuum pump |
| 5-7 p.2 ↗ | 151 | Size / type designation (2BV3 151) |
| field after 2BV3… p.2 ↗ | □ | Voltage code: 1 = 100/200 V, 4 = 115/230 V, 5 = 185-240 D / 320-415 Y (50 Hz) or 200-275 D / 345-480 Y (60 Hz) |
| field after voltage p.2 ↗ | □ | Casing / port plate / impeller material variant (e.g. bronze, stainless steel) |
| suffix p.2 ↗ | -Z | Option field (Z= substitution, e.g. M34, M74, D1, D6, G1, G5) |