Operating Instructions — DLR 100 ATEX compressor (BA 881-1-EN, ed. 1.3 02.08.2024, EN)

Technical Reference Summary

Covered Models & Document Scope

Covers the contact-free running claw compressors C-DLR 100, C-DLR 150, C-DLR 250, C-DLR 300, C-DLR 400 and C-DLR 500 in the ATEX version for explosive atmospheres (directive 2014/34/EU, explosion group IIB, temperature classes T2/T3). Document BA 881-1-EN, edition 1.3, 02.08.2024.

Section-by-Section Technical Breakdown

pp. 15-18
Product overview and functioning

Describes the C-DLR double-shaft rotary piston (claw) compressor design, its main components and the data plate. The claw rotors run contact-free and dry, synchronised by an oil-lubricated gear pair; the feed chamber has no sealants or lubricants. C-DLR 400/500 have grease-lubricated bearings on the B side. Cooling is by a drum fan drawing fresh air between compressor and insulation hood.

  • Double shaft rotary piston compressor with contact-free rolling claws, dry compression chamber
  • Synchronous gearbox and motor-side bearings oil-lubricated; C-DLR 400/500 B-side bearings grease-lubricated
  • Gearbox and compression chamber separated by special seals
  • Enclosed in insulation hood; drum fan draws cooling air in at E and discharges heated air at F
  • Driven by standard flanged three-phase motor via elastomer coupling; direct-on-line start, frequency converter optional for pressure control
  • Safety valve SV installed on outlet side for overload protection
  • Data plate includes type/size, serial number, year of construction, item no., motor speed, motor output, volume flow, excess pressure, ATEX markings inside/outside, test organisation and Ex-mark
pp. 17
Fields of application and operating limits

Defines permissible ambient and suction temperatures, inlet pressure range, maximum excess pressure and the pressure/temperature-class relationship with TZ01 setpoints. Also gives permissible leakage rates per size and maximum start frequency.

  • Ambient and suction temperature: +5 to +40 °C
  • Inlet pressure: atmospheric pressure ±80 mbar
  • Maximum excess pressure 2.0 bar must not be exceeded
  • Temperature class T3: max. +0.8 bar, TZ01 setpoint 130 °C; T2: +1.6/+1.8 bar at 195 °C, +2.0 bar at 210 °C
  • Frequency-converter operation 25–50 Hz: T2, +2.0 bar, TZ01 setpoint 210 °C
  • Leakage rate limits: 0.02 mbar·l/s (DLR 100/150), 0.04 (DLR 250/300), 0.06 (DLR 400/500)
  • Max. starts approx. 12/h (DLR 100–150), approx. 10/h (DLR 250–500)
pp. 17-18
Control and safety devices

Describes the pressure transmitter PZ01 in the inlet pipe, the temperature transmitter TZ01 in the outlet line and the safety valve SV. PZ01 limits prevent vacuum generation and excessive inlet pressure; TZ01 acts as excess-temperature safety shut-down. The control unit (PLC) is supplied by the user.

  • PZ01 limit min.: atmospheric pressure -80 mbar(g); limit max.: atmospheric pressure +80 mbar(g)
  • PZ01 can also be used for inlet-side control with PI controller and frequency converter (option)
  • TZ01 assigned warning and limit values in the control system; compressor switched off when limit reached
  • Safety valves open at 10 % above max. operating pressure
  • Safety valve must never be changed or disabled; replace immediately if suspected defective
  • Control unit (PLC) provided by user; compressor safety devices must be integrated in plant control concept
pp. 19-20
Installation

Covers installation conditions, erection, pipe connection and electrical/transmitter connection. Machine must be horizontal (max. 8° inclination), with clearances for cooling air and maintenance, and an external start sieve of 0.05 mm mesh. Forced ventilation is recommended where hazardous gas leakage is possible.

  • Machine freely accessible from all sides; ventilation grids/openings not covered
  • Max. inclination 8° in all directions; floor plane and even, load-bearing
  • Cooling air inlets/outlets at least 30 cm from adjacent walls; exhaust air must not be re-sucked
  • Maintenance clearance at least 40 cm around compressor
  • External start sieve with effective filter mesh size 0.05 mm required
  • Inlet line installed with fixed bearing as near as possible and with pitch
  • Output reduction noticeable above 1000 m altitude
pp. 23-26
Commissioning and decommissioning

Start-up procedure including installation check, motor relubrication, inerting, rotation-direction check and control check. Protective and safety functions (safety valve, pressure setpoints, temperature monitoring) must be tested as at first commissioning. Also covers switching off, decommissioning and recommissioning.

  • Installation check before start-up
  • Relubricate motor before start-up
  • Render compressor inert before commissioning
  • Check rotation direction and control
  • Test safety valve, pressure setpoints and temperature monitoring at first commissioning
  • Decommissioning and recommissioning procedures defined
pp. 27-35
Maintenance and repair

Maintenance table and procedures for oil level check, oil change, cleaning, motor and coupling, bearing lubrication, fan check and functional test of the safety valve. Inspection is due after 10,000 h and revision after 17,500 h. Spare parts and service information are included.

  • Maintenance table defines intervals and tasks
  • Oil level check and oil change procedures
  • Cleaning of compressor
  • Motor and coupling maintenance
  • Lubricate bearings
  • Check fan
  • Functional test of safety valve
  • Inspection after 10,000 h; revision after 17,500 h
  • Spare parts list E 881 referenced
pp. 36-37
Malfunctions: causes and elimination

Table of malfunctions with causes and remedies for compressor shutdown/restart failure, low flow rate, failure to reach final pressure, overheating, high end temperature and abnormal noise. Includes references to relevant chapters and service contact.

  • Compressor has switched off or cannot be restarted: motor protection switch, terminal box wiring, safety valve, flow rate, leaks, frequency converter
  • Final pressure not reached: leaks, frequency converter
  • Compressor gets too hot: ambient/inlet temperature, obstructed cooling air, dirty safety valve
  • Compressor end temperature too high: ambient/inlet temperature, temperature transmitter
  • Machine makes a strange noise: deposits on rotary piston, floating safety valve
  • Contact Elmo Rietschle Service for other malfunctions
pp. 39-41
Technical data

Compressor data, P&I diagram and characteristic curves. Provides reference data for selection and system integration.

  • Compressor data table
  • P&I diagram
  • Characteristic curves of compressor

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication S'applique à
Ambient and suction temperature range is +5 to +40 °C. p.17 ↗ Installation room and process gas must be kept within this range; outside it, operation is not intended use. C-DLR 100–500 ATEX
Inlet pressure must be atmospheric pressure ±80 mbar(g). p.17 ↗ PZ01 min./max. limits must be set to atmospheric pressure -80 mbar(g) and +80 mbar(g) to prevent vacuum or excessive inlet pressure. C-DLR 100–500 ATEX
Maximum excess pressure is 2.0 bar(g), depending on model and temperature class. p.17 ↗ Do not exceed the pressure permitted for the selected temperature class; safety valve opens at 10 % above max. operating pressure. C-DLR 100–500 ATEX
Temperature class T3: max. +0.8 bar, TZ01 setpoint 130 °C; T2: +1.6 bar and +1.8 bar at 195 °C, +2.0 bar at 210 °C. p.17 ↗ TZ01 warning/limit values in the control system must match the compressor temperature class and pressure. C-DLR 100–500 ATEX
Frequency-converter operation 25–50 Hz: T2, max. +2.0 bar, TZ01 setpoint 210 °C. p.17 ↗ When using the optional frequency converter, configure TZ01 for 210 °C and limit pressure to 2.0 bar. C-DLR 100–500 ATEX with frequency converter option
Leakage rate limits: 0.02 mbar·l/s (DLR 100/150), 0.04 mbar·l/s (DLR 250/300), 0.06 mbar·l/s (DLR 400/500). p.17 ↗ Compressor is not technically tight; account for these leakage rates in system design and ventilation. C-DLR 100/150, 250/300, 400/500
Max. number of starts: approx. 12 times per hour (DLR 100–150), approx. 10 times per hour (DLR 250–500). p.17 ↗ Frequent starting or high ambient/inlet temperatures may exceed motor winding and bearing temperature limits; size control cycles accordingly. C-DLR 100–150 and C-DLR 250–500
Safety valves open at 10 % above the max. operating pressure. p.18 ↗ Safety valve setpoint is fixed by the series design; never adjust or disable it. C-DLR 100–500 ATEX
Machine may only be operated horizontally with max. inclination 8° in all directions. p.19 ↗ Mount on a plane, even, load-bearing floor; otherwise damage and oil distribution problems may occur. C-DLR 100–500 ATEX
Cooling air inlets and outlets must be at least 30 cm from adjacent walls; maintenance clearance at least 40 cm around compressor. p.19 ↗ Provide sufficient free space to avoid overheating and to allow maintenance access. C-DLR 100–500 ATEX
External start sieve with effective filter mesh size 0.05 mm must be used to avoid foreign bodies being sucked in. p.20 ↗ Install suitable inlet filtration; clean pipelines of pollution and welding residues before connection. C-DLR 100–500 ATEX
Output reduction is noticeable when installed at more than 1000 m above sea level. p.20 ↗ Account for altitude derating in system design above 1000 m. C-DLR 100–500 ATEX
Maximum allowed flushing pressure is 0.5 bar(g). p.10 ↗ When flushing with nitrogen before maintenance or commissioning, do not exceed 0.5 bar(g). C-DLR 100–500 ATEX
Storage: relative humidity 0 % to 80 %, storage temperature -10 °C to +60 °C, dust-free and vibration-free, max. 6 months. p.14 ↗ Close openings air-tight and store in dry environment; longer storage requires special measures per info sheet I 150. C-DLR 100–500 ATEX
Inspection after 10,000 h and revision after 17,500 h. p.33 ↗ Plan maintenance intervals accordingly to maintain operational safety. C-DLR 100–500 ATEX
Compressor does not have its own Emergency Stop or Emergency Off. p.12 ↗ The operating company must integrate the compressor into the plant's protection concept (e.g. via a higher-level emergency stop). C-DLR 100–500 ATEX
ATEX marking example: II 3G Ex h IIB T3 Gc X (inside) and II 2G Ex h IIB T3 Gb X (outside). p.16 ↗ Verify the marking on the data plate matches the intended zone and gas group IIB. C-DLR 300 example; series ATEX

Faults & Troubleshooting

Code / Symptôme Possible Cause Remedy Note
Compressor has switched off or cannot be restarted p.36 ↗ Machine is switched off by the motor protection switch Check power supply voltage, frequency with motor data Chapter 5.6
Compressor has switched off or cannot be restarted p.36 ↗ Connection to motor terminal box is not correct Check by qualified electrician Chapter 5.6
Compressor has switched off or cannot be restarted p.36 ↗ Motor protection switch is not set correctly Use a motor protection switch with an overload-dependent turn-off delay that considers the short excess current at start up (version with short circuit and overload trigger as per VDE 0660 Part 102 or IEC 60947-4-1)
Compressor has switched off or cannot be restarted p.36 ↗ The safety valve is dirty so that the permissible pressure is exceeded Clean or replace the safety valve Chapter 7.2, Chapter 7.12
Compressor has switched off or cannot be restarted p.36 ↗ Safety valve is adjusted improperly or defective Check the safety valve and replace, if necessary Chapter 7.2, Chapter 7.12
Too low flow rate p.36 ↗ Filter in inlet line is polluted (provided by the user) Clean / replace the filter
Too low flow rate p.36 ↗ The pressure line is too long or too narrow Check the hose and/or the pipe Chapter 7.2
Too low flow rate p.36 ↗ Machine or system leaking Check the pipework and screw connections for leaks and check for tight fit Chapter 7.2
Too low flow rate p.36 ↗ Frequency converter does not control (optional) Check the frequency converter, check motor Manufacturer's data
Final pressure (max. excess pressure) has not been reached p.36 ↗ Machine or system leaking Check the pipework and screw connections for leaks and check for tight fit
Final pressure (max. excess pressure) has not been reached p.36 ↗ Frequency converter does not control (optional) Check the frequency converter, check motor Manufacturer's data
Compressor gets too hot p.37 ↗ Ambient or inlet temperatures too high Ensure proper use Chapter 2.3
Compressor gets too hot p.37 ↗ Cooling air supply is obstructed Check ambient conditions; clean ventilation slots Chapter 5.1, Chapter 7.5
Compressor gets too hot p.37 ↗ The safety valve is dirty so that the permissible pressure is exceeded Clean the safety valve and replace, if necessary Chapter 7.2, Chapter 7.12
Compressor end temperature too high p.37 ↗ Ambient or inlet temperatures too high Ensure proper use Chapter 2.3
Compressor end temperature too high p.37 ↗ Temperature transmitter is adjusted improperly or defective Check the temperature transmitter and replace, if necessary Chapter 7.9
The machine makes a strange noise p.37 ↗ Deposits on the rotary piston Clean the working space and the rotary piston Elmo Rietschle Service
The machine makes a strange noise p.37 ↗ The safety valve is floating Check the safety valve and replace, if necessary Chapter 7.2, Chapter 7.12