Technical Reference Summary
Covered Models & Document Scope
Bombas de vacío rotativas de paletas lubricadas con aceite V-VCB 20 y V-VCB 25 con motores de brida IE3, 50 Hz y 60 Hz, tensiones 3~ (230/400 V, 220/380 V, 200/346 V, 200/230 V, 400 V, 230/460 V, 330/380/660 V, 220/380/440 V, 200/400/690 V, 230/400/460 V)
Technical Data
| Parameter |
Value |
Condition |
| Suction capacity |
20 m³/h
p.2 ↗ |
V-VCB 20, 50 Hz |
| Suction capacity |
24 m³/h
p.2 ↗ |
V-VCB 25, 50 Hz |
| Suction capacity |
24 m³/h
p.2 ↗ |
V-VCB 20, 60 Hz |
| Suction capacity |
26,5 m³/h
p.2 ↗ |
V-VCB 25, 60 Hz |
| Ultimate vacuum |
2 mbar (abs.)
p.2 ↗ |
V-VCB 20 / 25 |
| Rated voltage |
230 / 400 V
p.2 ↗ |
3~, ±10% |
| Rated voltage |
220 / 380 V
p.2 ↗ |
3~, ±10% |
| Motor rating |
0,75 kW
p.2 ↗ |
V-VCB 20 / 25, 50 Hz |
| Motor rating |
0,9 kW
p.2 ↗ |
V-VCB 20 / 25, 60 Hz |
| Current drawn |
3,52 / 2,03 A
p.2 ↗ |
V-VCB 20, 60 Hz |
| Motor efficiency |
84,5 %
p.2 ↗ |
V-VCB 20, 60 Hz |
| Speed |
2850 min⁻¹
p.2 ↗ |
50 Hz |
| Speed |
3420 min⁻¹
p.2 ↗ |
60 Hz |
| Average noise level |
63 dB(A)
p.2 ↗ |
V-VCB 20, 50 Hz, EN ISO 3744 |
| Average noise level |
62 dB(A)
p.2 ↗ |
V-VCB 25, 50 Hz, EN ISO 3744 |
| Average noise level |
64 dB(A)
p.2 ↗ |
V-VCB 20, 60 Hz, EN ISO 3744 |
| Average noise level |
66 dB(A)
p.2 ↗ |
V-VCB 25, 60 Hz, EN ISO 3744 |
| Max. weight |
21 kg
p.2 ↗ |
V-VCB 20 |
| Max. weight |
23 kg
p.2 ↗ |
V-VCB 25 |
| Oil capacity |
0,35 l
p.2 ↗ |
V-VCB 20 / 25 |
| Protection class |
IP 55
p.1 ↗ |
flange motor |
| Insulation class |
F
p.1 ↗ |
flange motor |
Operating Limits
- Ultimate vacuum: 2 mbar (abs.)
p.2 ↗
- Rated voltage tolerance: ±10%
p.2 ↗
- Protection class: IP 55
p.1 ↗
- Insulation class: F
p.1 ↗
Type Code Decoder
| Position |
Token |
Meaning |
| 1-6
p.1 ↗ |
V-VCB |
Product series: oil-flooded rotary vane vacuum pump |
| 7-8
p.1 ↗ |
20 / 25 |
Size (nominal suction capacity class) |
| voltage field
p.2 ↗ |
Vx / Sx / Ux / Tx |
Voltage variant: Vx = 200/346 V Δ, 200/230 V Y, 400 V; Sx = 200/230 V Δ, 400 V Y, 230/460 V; Ux = 330/380/660 V Δ, 220/380/440 V Y; Tx = 200/400/690 V Δ, 230/400/460 V Y |