Induztr
Résumé technique Visionneuse de documents Modèles associés

Technical Data Sheet — IE3 compressor DE/EN)

Technical Reference Summary

Covered Models & Document Scope

Compresores rotativos de paletas de funcionamiento en seco V-DTR 100 y V-DTR 140 con motores IE3, variantes de 50 Hz y 60 Hz; variantes de potencia del motor 4.0 kW, 5.5 kW, 7.5 kW (50 Hz) y 6.5 kW, 9.0 kW (60 Hz); variantes de tensión xx Vx, xx Sx, xx Ux, xx Tx con conexión Δ/Y.

Technical Data

Parameter Value Condition
Capacity 100 m³/h p.2 ↗ V-DTR 100, 50 Hz
Capacity 100 m³/h p.2 ↗ V-DTR 140, 4.0 kW, 50 Hz
Capacity 130 m³/h p.2 ↗ V-DTR 140, 5.5 kW, 50 Hz
Capacity 120 m³/h p.2 ↗ V-DTR 140, 4.0 kW, 60 Hz
Capacity 155 m³/h p.2 ↗ V-DTR 140, 5.5 kW, 60 Hz
Overpressure 0,8 bar p.2 ↗ V-DTR 100, 50 Hz
Overpressure 1,4 bar p.2 ↗ V-DTR 140, 4.0 kW, 50 Hz
Overpressure 1,4 bar p.2 ↗ V-DTR 140, 5.5 kW, 50 Hz
Overpressure 1,0 bar p.2 ↗ V-DTR 140, 4.0 kW, 60 Hz
Overpressure 1,2 bar p.2 ↗ V-DTR 140, 5.5 kW, 60 Hz
Rated voltage 230 / 400 V ± 10 % p.2 ↗ V-DTR 100, 50 Hz
Rated voltage 400 / 690 V ± 10 % p.2 ↗ V-DTR 140, 50 Hz
Rated voltage 380 / 660 V ± 10 % p.2 ↗ V-DTR 140, 60 Hz
Motor power 4,0 kW p.2 ↗ V-DTR 100, 50 Hz
Motor power 5,5 kW p.2 ↗ V-DTR 140, 50 Hz
Motor power 7,5 kW p.2 ↗ V-DTR 140, 50 Hz
Motor power 6,5 kW p.2 ↗ V-DTR 140, 60 Hz
Motor power 9,0 kW p.2 ↗ V-DTR 140, 60 Hz
Current drawn 13,9 / 8,0 A p.2 ↗ V-DTR 100, 50 Hz
Current drawn 10,3 / 5,97 A p.2 ↗ V-DTR 140, 4.0 kW, 50 Hz
Current drawn 14,4 / 8,36 A p.2 ↗ V-DTR 140, 5.5 kW, 50 Hz
Motor efficiency 88,6 % p.2 ↗ V-DTR 100, 50 Hz
Motor efficiency 90,7 % p.2 ↗ V-DTR 140, 4.0 kW, 50 Hz
Motor efficiency 90,4 % p.2 ↗ V-DTR 140, 5.5 kW, 50 Hz
Speed 1455 rpm p.2 ↗ V-DTR 100, 50 Hz

Operating Limits

  • Max overpressure for continuous operation: 1,4 bar p.1 ↗
  • Capacity range: 100 to 153 m³/h p.1 ↗
  • Protection class: IP 55 p.1 ↗
  • Insulation class: F p.1 ↗

Type Code Decoder

Position Token Meaning
1-6 p.2 ↗ V-DTR Product series: dry running rotary vane compressor
7-9 p.2 ↗ 100 / 140 Size designation
field xx p.2 ↗ Vx / Sx / Ux / Tx Voltage variant / motor winding connection option

Modèles liés