Table 10 Dilutions of Spike Mix for Cyanine 3-labeling
Starting Amount of RNA Total RNA (ng)
Serial Dilution First
Serial Dilution Second
Serial Dilution Third
Serial Dilution Fourth
Spike Mix Volume to be used in each labeling reaction (µL)
25
1:20
1:25
1:20
1:4
2
50
1:20
1:25
1:20
1:2
2
100
1:20
1:25
1:20
2
Use RNase-free microfuge tubes and tips. Make sure you dispense at least 2 µL with a pipette to ensure accuracy.
Table 11 WT Primer MasterMix
Component
Volume (µL) per reaction
Volume (µL) per 5 reaction
Volume (µL) per 10 reactions
WT Primer
1
5
10
Diluted Spike Mix
2
10
20
Total Volume
3
15
30
Table 12 cDNA Master Mix
Component
Volume (µL) per reaction
Volume (µL) per 5 reaction
Volume (µL) per 10 reactions
5× First Strand Buffer (green cap)
2
10
20
0.1 M DTT (white cap)
1
5
10
10 mM dNTP Mix (green cap)
0.5
2.5
5
Affinity Script RNase Block Mix (violet cap)
1.2
6
12
Total Volume
4.7
23.5
47
Engineering Facts
14 facts · every claim linked to a page
Selection
The protocol requires the C scanner because Agilent Exon Microarrays are only available on SurePrint G3 formats.
Scanner compatibility must be confirmed before selecting the microarray platform.
Source
“The C scanner is required, as Agilent Exon Microarrays are available only on the Agilent SurePrint G3 microarray formats.”
Selection
The 1-pack microarray format requires 100 ng total RNA, while 2-, 4-, and 8-pack formats require 25 ng (50 ng recommended).
Sample input amount determines which slide format can be used.
Source
“The starting input requirement for the 2-pack, 4-pack and 8-pack microarrays is 25 ng of total RNA (50 ng is recommended).”
Operation
The recommended specific activity for hybridization is 15 pmol cyanine 3 per microgram cRNA.
Labeling yield must meet this specification for successful hybridization.
Source
“The recommended Specific Activity for hybridization is increased to 15 pmol cyanine 3 per μg cRNA.”
Installation
Microarray slides must be stored at room temperature in the dark under vacuum desiccation or nitrogen purge after opening the foil pouch.
Proper storage environment prevents slide degradation before use.
Source
“After breaking foil on microarray pouch, store microarray slides at room temperature (in the dark) under a vacuum dessicator or nitrogen purge box.”
Maintenance
The hybridization oven must be calibrated regularly to ensure accuracy of collected data.
Oven calibration is a scheduled maintenance task affecting data quality.
Source
“You must calibrate the hybridization oven regularly for accuracy of the collected data.”
Operation
Hybridization sample volumes differ by slide format: 490 µL for 1-pack, 240 µL for 2-pack, 100 µL for 4-pack, and 40 µL for 8-pack.
Correct hybridization volume must be matched to the slide format to avoid leakage or insufficient coverage.
Source
“Volume to Hybridize 490 µL 240 µL 100 µL 40 µL”
Operation
Adding 0.005% Triton X-102 to wash buffers reduces the possibility of array wash artifacts.
Wash buffer additive is needed to prevent artifacts that could compromise data.
Source
“The addition of 0.005% Triton X-102 (10%) to the Gene Expression wash buffers reduces the possibility of array wash artifacts.”
Safety
The microarray wash procedure must be performed where ozone levels are 50 ppb or less.
Laboratory ozone level must be verified before installing the wash workflow.
Source
“The microarray wash procedure for the Agilent one-color platform must be done in environments where ozone levels are 50 ppb or less.”
Operation
Slides should be scanned immediately after washing to minimize environmental oxidant impact on signal intensities.
Delay between wash and scan degrades signal and should be minimized in workflow planning.
Source
“Scan slides immediately to minimize the impact of environmental oxidants on signal intensities.”
Conformité
Feature Extraction version 10.7.3 or later is required to extract Gene Expression Exon microarray data.
Software version must be verified before data extraction can proceed.
Source
“Extraction of Gene Expression Exon microarrays is supported by Feature Extraction version 10.7.3 or later.”
Operation
The thermocycler protocol can slightly lower cRNA yield compared to water baths.
Choice of incubation equipment affects yield and should be considered during setup.
Source
“The use of a thermocycler can slightly lower the yield of cRNA when compared to the use of water baths.”
Performance
Labeled cRNA should show a broad band with majority signal between 200 and 2000 nucleotides; samples with distinct bands below 200 nucleotides should not proceed.
Quality acceptance criterion for cRNA before hybridization.
Source
“The majority of signal for amplified sample should fall into the size range from 200 to 2000 nucleotides.”
Safety
Ozone levels above 50 ppb can significantly affect Cy3 signal and compromise microarray performance.
Environmental ozone control is required to protect dye signal integrity.
Source
“Beyond this level, ozone can significantly affect Cy3 signal and compromise microarray performance.”
Operation
Never allow the microarray surface to dry out during hybridization and washing steps.
Drying causes irreparable damage and must be prevented during handling.
Source
“Never allow the microarray surface to dry out during the hybridization process and washing steps.”