Huber CS 200-H Circulating Bath Datasheet

Sommaire

  1. Overview p. 1
    Product identification and general description of the CS 200-H unit
  2. Spec p. 2
    Technical data according to DIN 12876 including performance values
  3. p. 1 table, 33 rows

Technical data according to DIN 12876 — Huber CS 200-H (VDH4100091)

ParameterValue
Order-No.VDH4100091
Operating temperature range-20...85 °C
temperature set point / displaycolour LED Touchscreen
Internal temperature sensorPt100
Temperature stability at -10°C1,5 K
Interface digitalRS232
Safety classificationI / NFL
Heating power5,5 kW
Cooling power at ambient temperature 20°C
at 15°C28 kW
at 10°C20 kW
at 0°C18 kW
at -10°C15 kW
at -20°C9,5 kW
Refrigeration machineair-cooled, CFC- and HCFC-free
Refrigerant (ASHRAE, GHS)R-449A (A1, H280)
Refrigerant quantity12 kg
CO2 equivalent16,76 t
Circulation pump: max. delivery125 l/min
max. delivery pressure4,7 bar
Pump connectionG1 male
min. filling capacity225 l
max. filling capacity245 l
Overall dimensions WxDxH **1400x1000x1800 mm
Net weight535 kg
sound pressure level +/- 4 dB(A)78 dB(A)
Power supply (3 Phase)460V 3~ 60Hz
max. current (3 Phase)49 A
Fuse (3 phase)3x60A
Degree of ProtectionIP20
min. ambient temperature5 °C
max. ambient temperature32 °C
from Serial-No.:1.0/20

** Overall dimensions WxDxH. Technical details and dimensions are subject to change. No liability is accepted for errors or omissions. Illustrations can deviate from the original.

Engineering Facts

13 facts · every claim linked to a page
Selection

The chiller's cooling capacity is rated at 20°C ambient and will drop if ambient temperature rises, so sizing must account for actual room conditions.

Cooling capacity must be derated for higher ambient temperatures to avoid undersizing.

Source
“Output data valid for: Room temperature 20°C. If the ambient temperature rises, the cooling capacity may drop.”
Installation

The unit requires a 460V 3-phase 60Hz supply with a 3x60A fuse and draws up to 49A, so the electrical infrastructure must be sized accordingly.

Electrical supply and protection must match the specified voltage, frequency, current, and fuse rating.

Source
“Power supply (3 Phase) 460V 3~ 60Hz”
Installation

Three-phase devices under 63A are delivered with cable but without a plug, so a suitable plug must be provided on site.

The installer must plan for a compatible plug and connection point.

Source
“Three-phase devices with current consumption less than 63A --> with cable, without plug”
Installation

Voltage and frequency tolerances are interdependent: a -5% voltage with +2% frequency is not allowed, so supply quality must be verified.

Non-compliant supply combinations can damage the equipment or void warranty.

Source
“-5% voltage and +2% frequency -> not allowed!”
Installation

The chiller must be installed in an ambient temperature between 5°C and 32°C, so the room climate must be controlled.

Operating outside the ambient range may reduce performance or cause malfunction.

Source
“min. ambient temperature 5 °C”
Safety

The refrigerant R-449A is classified A1 with GHS hazard H280, so refrigerant handling and ventilation precautions are required.

Personnel must be aware of the refrigerant hazard and applicable safety measures.

Source
“R-449A (A1, H280)”
Safety

The unit has a CO2 equivalent of 16.76 t from 12 kg of R-449A, which affects refrigerant leak reporting and environmental compliance.

Operators must comply with refrigerant leak-check and reporting obligations based on CO2 equivalent.

Source
“CO2 equivalent 16,76 t”
Operation

The recommended thermofluid is a 50:50 water-monoethylene glycol mixture, so the correct fluid must be used for the temperature range.

Using the wrong fluid can affect heat transfer, pump performance, and freeze protection.

Source
“Recommended thermofluid: Water - Monoethylene Glycol 50:50”
Operation

The flow rate can be adjusted via a manual bypass valve on the backside, allowing the user to match circulation to the application.

Proper flow adjustment is needed to meet process requirements and avoid pump overload.

Source
“The flow rate can be adjusted via the manual bypass valve on the backside of the chiller.”
Performance

The circulation pump delivers up to 125 l/min at 4.7 bar, which must be sufficient for the connected circuit's pressure drop.

Pump pressure must overcome system resistance; insufficient pressure leads to low flow.

Source
“max. delivery pressure 4,7 bar”
Performance

The internal tank holds between 225 and 245 liters, so the system volume and fluid inventory must be planned accordingly.

Fluid volume affects thermal inertia, cost, and filling/draining procedures.

Source
“min. filling capacity 225 l”
Conformité

The equipment emits Class A, Group 1 disturbances per EN55011, so it may require additional EMC measures in residential or sensitive environments.

Class A equipment is not intended for residential use without additional filtering.

Source
“Classification (disturbance) to EN55011: Class A, Group 1”
Installation

Space requirements must be respected, and operating conditions are available online, so clearance and ventilation must be planned.

Insufficient clearance can cause overheating and reduced cooling performance.

Source
“Please respect space requirements. See operating conditions at www.huber-online.com”