Agilent Technologies 1260 Infinity II Preparative LC System | UV based Prep HPLC
Agilent Technologies ·Fabriqué en USA · En production active

Agilent Technologies 1260 Infinity II Preparative LC System | UV based Prep HPLC

Agilent Technologies 1260 Infinity II Preparative LC System | UV based Prep HPLC — Chromatographie liquide con Puissance moteur 0.103 kW.

The 1260 Infinity II Preparative LC System is a UV-based preparative HPLC platform built around the G7157A preparative autosampler, which injects 0.1–900 µL at up to 400 bar. It is the UV-detection preparative configuration of the 1260 Infinity II series, distinguished from the manual preparative and analytical-scale purification siblings by automated high-volume injection. It serves as the injection and separation front end of a preparative purification train feeding fraction collection.

Télécharger la fiche (PDF)
Puissance moteur
0.103 kW

Agilent Technologies Preparative HPLC Systems Series — Model Comparison & Selection

Modèle Column inner diameter, mmTypical flow rate, mL/minPlate count, Nth/meterRetention time, minCarryover, %Sample capacity
1260 Infinity II Preparative LC System | UV based Prep HPLC Actuel 1...314060615.185132
1220 Infinity II Analytical-Scale LC Purification System 4.61————
1260 Analytical-Scale Purification System | Preparative HPLC 1...314060615.18——
1260 Infinity Bio-Inert Analytical-Scale LC Purification System 1...314060615.18——
1260 Infinity II Manual Preparative LC System 1...314060615.18——
1260 Prime Bio Analytical-Scale Purification System 4.61——9×10⁻⁴6144
1290 Analytical-Scale LC Purification 1...314060615.18——
1290 Infinity Autoscale Preparative system 1...314060615.18——
1290 Infinity III 4.61——9×10⁻⁴6144
1290 Infinity II Preparative LC System 1...314060615.18——
Automated LC/MSD purification| High-precision| Complex mixtures 1...314060615.18——
Flexible HPLC/UHPLC, Prime Analytical-Scale Purification System 1...314060615.18——
High-throughput Purification | Drug discovery | Biological 1...314060615.18——
Preparative LC/MSD System | Enhanced Purification & Efficiency 1...314060615.18——

Spécifications complètes

Prestaciones y funciones principales
Puissance moteur 350 BTU/h
Report 0.005 percent
Température de colonne 4 °C
Pression de service maximale 400 bar
Nombre de plateaux 40606 Nth/meter
Temps de rétention 15.18 min
Capacité d'échantillons 132 vial
Débit typique 1 mL/min
Productivity range mfr Micrograms Micrograms
Asymmetry mfr 1.27
Injection volume range mfr 0.1...900 μL
Maximum draw volume per step mfr 100 μL
Sample Cooler Function Test duration mfr 15 min
Bench clearance side mfr 2.5 cm
Bench clearance rear mfr 8 cm
IP address: mfr 192.168.254.11
Subnet Mask: mfr 255.255.255.0
Default Gateway mfr not specified specified
? mfr displays syntax and descriptions of commands com
ip <x.x.x.x> mfr sets new ip address address
sm <x.x.x.x> mfr sets new subnet mask mask
gw <x.x.x.x> mfr sets new default gateway gateway
exit mfr exits shell and saves all changes changes
Settable injection range mfr 0.1...900 extension
Injection precision mfr 500...3600
Injection cycle time mfr 60 μL
Communications mfr Controller-area network , Local Area Network ERI
Housing mfr All materials recyclable. recyclable.
Safety standards: mfr IEC, EN, CSA, UL UL
ISM Classification mfr 1 B
Dimensiones, peso y diseño mecánico
Diamètre interne de colonne 1...3 in
Poids 6 kg
Dimensions (height × width × depth) mfr 205 mm
Dimensions (height x width x depth) mfr 205 mm
Eléctrico, alimentación y accionamiento
Courant 10 max.
Alimentation 24 VDC
Sample thermostat heater resistance acceptance range mfr 5...9 Ohm
Line voltage mfr 100...240
Line frequency mfr 50
Materials, Media & Process Compatibility
Sample viscosity range mfr 0.2...5 cP
Refrigerant gas mfr 600 a
Condiciones de servicio, entorno y protección
Altitude de fonctionnement 3000 m
Sample Cooler Function Test final stability mfr 1.0 °C
Humidity mfr 95 °C
Non-operating altitude mfr 4600 m
Normas, seguridad y datos generales
Safety standards: IEC, EN, CSA, UL mfr 2

Description

Construction and positioning

Behavior and media

Installation, control and operation

Integration & Operating Notes

Process Limits
Keep system pressure at or below 400 bar at the injection head

The G7157A injection head is rated to 400 bar; column back pressure plus plumbing restriction must stay under this figure, otherwise the sampling sequence can fail or the metering device can be damaged. Size columns and flow rates so the preparative load does not push the head past its rating.

User Manual, page 12
Process Limits
Do not use DMF in the mobile phase

Dimethylformamide attacks the PVDF leak sensor and causes corrosion. If DMF is required by the method, the leak sensor must be treated as a consumable and inspected regularly, or the method moved to a compatible solvent.

User Manual, page 23
Control & I/O
Single Draw step capped at 100 µL; sequence larger volumes

A Draw step command cannot exceed 100 µL. For injections up to the 900 µL head volume, the method must chain multiple draw steps and return the plunger home between them; otherwise the sampler aborts the step and reports an error.

User Manual, page 121
Maintenance
Run Automatic Referencing after any internal repair

Corrected gripper positions are stored in firmware, so after repair of internal components the Calibration Tool Kit G7129-60014 must be used with the four tray reference points; the Gripper Verification Test (positions 1, 11, 39, 56, 66, 101, 111, 139, 156, 166) confirms alignment.

User Manual, pages 119–120
Maintenance
Install park position and transport foam before shipping

The arm must be moved to Park Arm and Transport Protection Foam G7129-40050 fitted before transport; shipping without both risks mechanical damage to the transport assembly and requires re-referencing on arrival.

User Manual, page 117

Selection & Integration Q&A

When should I choose this UV-based preparative system rather than the Manual Preparative LC System or an Analytical-Scale Purification System?

Pick this system when automated injection of 0.1–900 µL at up to 400 bar and UV-directed fraction collection are needed. The Manual Preparative system lacks the automated G7157A sampler; the 1220/1260 Analytical-Scale Purification systems are for analytical loads, not preparative injection volumes.

What must the rest of the HPLC train provide to work with the G7157A autosampler?

A pump and column capable of staying within the 400 bar head rating, flush solvent for the post-injection metering-device flush, and waste disposal via the recommended 6 L can with Stay Safe cap GL45 4-port (5043-1221). The injection valve uses five of six ports; port 3 is not connectable.

What maintenance actions and accessories are needed beyond base delivery?

Plan for Calibration Tool Kit G7129-60014 for Automatic Referencing, Transport Protection Foam G7129-40050 for shipping, and Lab Advisor B.02.11+ (heater resistance test) or 2.19+ (Sample Cooler Function Test) if a Sample Cooler/Thermostat is fitted. EMF tracks wear; maintenance positions cover needle, metering seal/piston and gripper changes.

Plans dimensionnels et documentation technique

Dessins dimensionnels

performance curve performance curve

Click drawing to inspect vector dimensions

Documentation technique

PDF
Agilent 1260 Infinity II Preparative Autosampler User Manual
Manual ·289 pp.
Voir le PDF