Elmo Rietschle V-DTE
Elmo Rietschle V-DTE — Systèmes de vide industriels et médicaux centralisés con Pression différentielle max. 1000 mbar, Puissance moteur 145 kW, Niveau sonore 58 dB.
The V-DTE is a side-channel blower configured as a single-stage, dry-running vacuum/pressure source with a G 1/8 inlet connection. It delivers 3.5 m³/h at 50 Hz (4.2 m³/h at 60 Hz) and up to 1.0 bar differential pressure, distinguishing it from larger siblings by its compact 0.12–0.145 kW motor and 6.5 kg frame. It is intended for integration into central vacuum or pressure systems where low flow and moderate pressure rise are required.
Spécifications complètes
| Pression différentielle max. | 1.0 bar (50 Hz | 3~) 50 Hz | 1~: 1.0 bar |
| Puissance moteur | 0.120 kW (50 Hz | 3~) 60 Hz | 3~: 0.145 kW · 50 Hz | 1~: 0.120 kW · 60 Hz | 1~: 0.145 kW |
| Niveau sonore | 57 dB (50 Hz) 60 Hz: 58 dB |
| Vitesse de pompage | 3.5 m³/hour (50 Hz) 60 Hz: 4.2 m³/hour |
| Vitesse de rotation | 2700 - 2860 rpm (50 Hz) |
| a mfr | 208 mm |
| b mfr | 156 mm |
| c mfr | 151 mm |
| d mfr | 24 mm |
| l mfr | 78 mm |
| r mfr | 60 mm |
| øs mfr | 8-10 mm |
| øw mfr | 125 mm |
| R mfr | G 1/8 |
| Model code mfr | V-DTE |
| Volume flow mfr | 3.5 m3/h (50 Hz) |
| Volume flow mfr | 4.2 m3/h (60 Hz) |
| Overpressure mfr | 1.0 bar (3~) |
| Overpressure mfr | 1.0 bar (1~) |
| ZRD mfr | 6 |
| ZRK mfr | 6 (03) |
| Poids | 6.5 kg |
| Hauteur | 151 mm |
| Longueur | 208 mm |
| Largeur | 156 mm |
| Dimension a mfr | 208 mm |
| Dimension b mfr | 156 mm |
| Dimension c mfr | 151 mm |
| Dimension d mfr | 24 mm |
| Dimension l mfr | 78 mm |
| Dimension r mfr | 60 mm |
| Courant | 1.12 / 0.71 A (50 Hz | 3~/1~) 60 Hz | 3~/1~: 1.02 / 0.62 A · 50 Hz | 1~: 1.3 A · 60 Hz | 1~: 1.4 A |
| Motor rating mfr | 0.145 kW (60 Hz) |
| Current drawn mfr | 1.3 A (50 Hz) |
| Current drawn mfr | 1.4 A (60 Hz) |
| Motor starter ZMS (3~) mfr | 16 / 10 A (50 Hz) |
| Motor starter ZMS (3~) mfr | 16 / 10 A (60 Hz) |
| Motor starter ZMS (1~) mfr | 16 A (50 Hz) |
| Motor starter ZMS (1~) mfr | 16 A (60 Hz) |
| Raccord d'entrée | G 1/8 |
| Average noise level mfr | 58 dB(A) (60 Hz) |
Description
Construction and series positioning
- The V-DTE is a side-channel blower with a single impeller directly driven by a 2-pole AC motor; no belts or gears are used.
- Within the V-DTE series (sizes 3, 6, 8, 10), this model corresponds to size 6, as indicated by the ZRD 6 accessory code and the 3.5 m³/h flow at 50 Hz.
- The inlet connection is G 1/8, and the discharge is also G 1/8 (dimension R). The unit measures 208 mm (a) × 156 mm (b) × 151 mm (c) and weighs 6.5 kg.
- Motor variants cover 50 Hz and 60 Hz, with both 1~ and 3~ supplies; motor rating is 0.120 kW at 50 Hz and 0.145 kW at 60 Hz.
Behavior under load and media
- Maximum differential pressure is 1.0 bar for both 1~ and 3~ variants at 50 Hz; no separate 60 Hz pressure rating is listed, so the 1.0 bar limit should be treated as the working ceiling unless otherwise confirmed.
- Pumping speed is 3.5 m³/h at 50 Hz and 4.2 m³/h at 60 Hz, with rotational speed 2700–2860 rpm at 50 Hz.
- The blower is dry-running and oil-free; it is not intended for liquid or particulate-laden media. No curve points are available, so flow–pressure behavior must be obtained from the manufacturer’s performance curve for the exact voltage and frequency.
- Noise level is 57 dB(A) at 50 Hz and 58 dB(A) at 60 Hz, measured at the factory; this is relevant for indoor installations but does not imply a specific sound pressure at 1 m without the measurement condition.
Installation, connection and operation
- The unit is foot-mounted via the base; the mounting hole diameter (øs) is 8–10 mm, and the mounting footprint dimensions are given as l = 78 mm, r = 60 mm, øw = 125 mm, d = 24 mm.
- Electrical connection must match the motor variant ordered: 1~ or 3~, 50 Hz or 60 Hz. Current drawn is 1.3 A (50 Hz, 1~), 1.4 A (60 Hz, 1~), 1.12/0.71 A (50 Hz, 3~/1~) and 1.02/0.62 A (60 Hz, 3~/1~).
- The spare parts list covers accessories ZRD, ZRK and ZMS; these are not included in the base delivery and must be specified separately if required.
- No certificates or application-specific approvals are listed for this model; verify suitability for the intended vacuum system against local codes.
Integration & Operating Notes
The maximum differential pressure is 1.0 bar for both 1~ and 3~ variants at 50 Hz. Operation above this limit can cause motor overload, excessive heating and mechanical damage. Because no separate 60 Hz pressure rating is provided, the same 1.0 bar ceiling should be applied unless the manufacturer confirms otherwise for the 60 Hz variant.
The V-DTE is available with 1~ or 3~ motors for 50 Hz or 60 Hz. Current draw differs by variant: 1.3 A (50 Hz, 1~), 1.4 A (60 Hz, 1~), 1.12/0.71 A (50 Hz, 3~/1~) and 1.02/0.62 A (60 Hz, 3~/1~). Supplying the wrong frequency or phase will alter speed, flow and pressure, and may overload the motor. Confirm the nameplate matches the site supply before connection.
The base has mounting holes of 8–10 mm diameter on a 125 mm circle (øw), with footprint dimensions l = 78 mm and r = 60 mm. The unit weighs 6.5 kg, so the mounting surface must be flat and rigid enough to avoid vibration transmission. Ensure fasteners are long enough to engage the base fully without protruding into the impeller chamber.
The spare parts list covers the V-DTE series with accessories ZRD, ZRK and ZMS. These are not part of the base delivery and must be ordered as separate line items if required for the installation. The ZRD 6 code on this model indicates the size 6 accessory group; verify the exact accessory part number against the spare parts list before ordering.
Selection & Integration Q&A
Choose the size 6 when the required flow is about 3.5 m³/h at 50 Hz (4.2 m³/h at 60 Hz) and differential pressure does not exceed 1.0 bar. Smaller sizes (3) give less flow; larger sizes (8, 10) give more flow but draw higher motor power and weigh more. The size 6 is the balance point for low-flow, moderate-pressure vacuum or pressure systems.
The inlet and discharge connections are G 1/8. Use mating fittings rated for at least 1.0 bar differential pressure and suitable for the process gas. The blower is dry-running and oil-free, so no lubricant or seal fluid is needed. Ensure piping is supported independently to avoid loading the blower casing, and include a filter on the inlet if particulate matter is present.
The blower is oil-free and requires no routine lubrication. Inspect inlet filters periodically and check for wear on the impeller and bearings after extended operation. Accessories ZRD, ZRK and ZMS are available but not included in the base delivery; order them separately if needed. Refer to the spare parts list for the size 6 (ZRD 6) part numbers.