Shimadzu Lightnirs
Shimadzu ·Fabriqué en Japan · En production active

Shimadzu Lightnirs

Shimadzu Lightnirs — Life science instruments.

El Shimadzu Lightnirs es un oxímetro de tejido de infrarrojo cercano compacto que utiliza láseres semiconductores de 3 longitudes de onda y un fotodiodo de avalancha para medir Oxy-Hb, Deoxy-Hb y Total-Hb. Su carcasa de 253×222×68 mm y 1,6 kg acepta 15 V de un adaptador de CA o de una batería de iones de litio y proporciona 3 entradas digitales y 10 analógicas. Sirve como unidad de monitorización portátil en entornos de ciencias de la vida e investigación clínica.

Télécharger la fiche (PDF)

Spécifications complètes

Prestaciones y funciones principales
Source lumineuse 3-wavelength near-infrared semiconductor laser
Longueur d'onde 780, 805, 830 nm
Measurement channels (Holder Type A, forehead) (Holder Type A, one unit) mfr 2×8 (22ch) ch (Holder Type A, one unit)
Measurement channels (Holder Type A, dorsolateral prefrontal area) (Holder Type A, one unit) mfr 2×4 (10ch)×2 ch (Holder Type A, one unit)
Measurement channels (Holder Type A, language area) (Holder Type A, one unit) mfr 2×4 (10ch)×2 ch (Holder Type A, one unit)
Measurement channels (Holder Type A, dorsolateral prefrontal cortex + prefrontal area) (Holder Type A, two-unit connecti mfr 3×10 (47ch) ch (Holder Type A, two-unit connecting system)
Measurement channels (Holder Type A, supplementary motor area) (Holder Type A, two-unit connecting system (both)) mfr 3×5 (24ch)×2 ch (Holder Type A, two-unit connecting system (both))
Measurement channels (Holder Type B, primary motor area) (Holder Type B) mfr 2×8 (22ch) ch (Holder Type B)
Measurement channels (Holder Type B, visual area and frontal pole) (Holder Type B) mfr 2×4 (10ch)×2 ch (Holder Type B)
Measurement channels (Holder Type B, frontal pole + visual cortex + somatosensory) (Holder Type B) mfr 2×4+4×6 (48ch) ch (Holder Type B)
Measurement channels (Holder Type B, motor area) (Holder Type B) mfr 4×8 (52ch) ch (Holder Type B)
Optical fiber pairs (selectable optical fiber) mfr 8 pairs pairs (selectable optical fiber)
Number of subjects (study data) mfr 8 (study data)
Measured region (study data) mfr Frontal pole 3 × 3 (12-channel) (study data)
Rest period (block design) mfr 10 sec (block design)
Oral tasting period (block design) mfr 20 sec (block design)
Rest period after swallowing (block design) mfr 30 sec (block design)
Jelly sample amount (4 types of jelly) mfr about 5 g (4 types of jelly)
Scalable system configuration (system configuration) mfr 4 up to 40 sets (system configuration)
L-type optic fiber cable expansion (L-type optic fiber cable) mfr +12 sets (L-type optic fiber cable)

Description

Integration & Operating Notes

Selection & Integration Q&A

Plans dimensionnels et documentation technique

Documentation technique

PDF
c297-e103
Datasheet ·2,0 МБ ·8 pp.
Voir le PDF
PDF
c297-e089
Datasheet ·5,6 МБ ·24 pp.
Voir le PDF
PDF
c297-e153
Datasheet ·328,4 КБ ·2 pp.
Voir le PDF