Waters Waters Fraction Collection III for Sample Purification
Waters ·Fabriqué en USA · En production active

Waters Waters Fraction Collection III for Sample Purification

Waters Waters Fraction Collection III for Sample Purification — Automatisation et équipement de laboratoire.

The Waters Fraction Collection III is a benchtop fraction collector with a 0.1 s nozzle shift time and a maximum flow rate of 300 mL/min, designed for sample purification in laboratory workflows. It accepts 10 mV or 1 V full-scale detector signals and provides RS-232C communication, operating in environments from 2 to 40 °C. This model is suited for automated peak-based fraction collection where fast, precise tube positioning is required.

Télécharger la fiche (PDF)

Spécifications complètes

Prestaciones y funciones principales
Nozzle shift time mfr 0.1 s (tube center to center)
Power requirements mfr 100.00 V AC / 115.00 V AC / 240.00 V AC, 0.23 A
External dimensions mfr Width: 28.60 cm (11.27 in.); Depth: 35.90 cm (14
Temperature range mfr 2 to 40 °C (35 to 104 °F)
Maximum flow rate mfr 300 mL per minute
Bench space mfr W 311 mm × D 413 mm × H 362 mm mm
Dimensiones, peso y diseño mecánico
Poids 7.0 kg
Eléctrico, alimentación y accionamiento
Power mfr 0.23 A (100 V, 50 to 60 Hz)
Power mfr 0.2 A (115 V, 50 to 60 Hz)
Power mfr 0.15 A (240 V, 50 to 60 Hz)
Interfaces, conexiones y control
Serial interface mfr RS-232C (9-pin connector)
Signal input mfr 10 mV or 1 V full scale
Operation display mfr 40 characters by 8 rows (LCD w/backlight)
Condiciones de servicio, entorno y protección
Relative humidity mfr 20 to 85 % (noncondensing)

Description

Construction and positioning

Integration & Operating Notes

Control & I/O
Detector output must match 10 mV or 1 V full scale

The analog input expects either 10 mV or 1 V full-scale signals. Verify the detector output range and configure accordingly to ensure correct peak detection and fraction triggering.

Factory Specification Sheet
Process Limits
Do not exceed 300 mL/min flow rate

The maximum supported flow rate is 300 mL per minute. Exceeding this may cause inaccurate fraction collection or mechanical stress; ensure the pump and plumbing are set within this limit.

Factory Specification Sheet

Selection & Integration Q&A

What detector output and communication interface are required to integrate this fraction collector with my existing HPLC system?

The collector accepts analog signals of 10 mV or 1 V full scale and communicates via RS-232C (9-pin). Ensure your detector provides a compatible output and that your control system has an available serial port.

What maintenance is required and what accessories are included with the base unit?

No maintenance schedule or included accessories are detailed in the provided facts. The base delivery typically includes the collector, power cord, and manual; confirm with the supplier for specific consumables like tubes and racks.

Plans dimensionnels et documentation technique

Documentation technique

PDF
Fraction Collector III Operator's Guide
Manual ·1,7 МБ ·138 pp.
Voir le PDF