Induztr
Résumé technique Visionneuse de documents Modèles associés

Data Sheet Model MK CO₂ 1020

Technical Reference Summary

Covered Models & Document Scope

Cámara climática dinámica de CO₂ modelo MK 1020 para cambios rápidos de temperatura, volumen interior de 991 L. Dos variantes de alimentación: MK1020CO2-400V (400 V 3~/N/PE 50 Hz, n.º de art. 9020-0527) y MK1020CO2-480V (480 V 3~/N/PE 60 Hz, n.º de art. 9020-0529).

Technical Data

Parameter Value Condition
Temperature range -48...180 °C p.3 ↗ MK1020CO2-400V, 50 Hz
Temperature uniformity dependent on set 0.1...1.0 ± K p.3 ↗ MK1020CO2-400V, 50 Hz
Temperature fluctuation dependent on set 0.1...0.2 ± K p.3 ↗ MK1020CO2-400V, 50 Hz
Cooling down time from 180°C to -40°C 70 min p.3 ↗ MK1020CO2-400V, 50 Hz
Rated voltage 400 V p.3 ↗ MK1020CO2-400V, 50 Hz
Power frequency 50 Hz p.3 ↗ MK1020CO2-400V
Nominal power 9,6 kW p.3 ↗ MK1020CO2-400V, 50 Hz
Unit fuse 32,0 A p.3 ↗ MK1020CO2-400V, 50 Hz
Phase (nominal voltage) 3~/N/PE p.3 ↗ MK1020CO2-400V, 50 Hz
Interior volume 991 L p.3 ↗ MK1020CO2-400V, 50 Hz
Net weight of the unit (empty) 556 kg p.3 ↗ MK1020CO2-400V, 50 Hz
Load per rack 40 kg p.3 ↗ MK1020CO2-400V, 50 Hz
Permitted load 200 kg p.3 ↗ MK1020CO2-400V, 50 Hz
Wall clearance back 300 mm p.3 ↗ MK1020CO2-400V, 50 Hz
Wall clearance sidewise 200 mm p.3 ↗ MK1020CO2-400V, 50 Hz
Width net 1,580 mm p.3 ↗ MK1020CO2-400V, 50 Hz
Height net 2,005 mm p.3 ↗ MK1020CO2-400V, 50 Hz
Depth net 1,480 mm p.3 ↗ MK1020CO2-400V, 50 Hz
Interior width 1,200 mm p.4 ↗ MK1020CO2-400V, 50 Hz
Interior height 1,020 mm p.4 ↗ MK1020CO2-400V, 50 Hz
Interior depth 810 mm p.4 ↗ MK1020CO2-400V, 50 Hz
Unit doors 1 p.4 ↗ MK1020CO2-400V, 50 Hz
Sound-pressure level 62 dB(A) p.4 ↗ MK1020CO2-400V, 50 Hz
Energy consumption at 25°C 2,500 Wh/h p.4 ↗ MK1020CO2-400V, 50 Hz
Number of shelves (std./max.) 1/11 p.4 ↗ MK1020CO2-400V, 50 Hz

Operating Limits

  • Temperature range: -48...180 °C p.3 ↗
  • Permitted load: 200 kg p.3 ↗
  • Load per rack: 40 kg p.3 ↗
  • Wall clearance back: 300 mm p.3 ↗
  • Wall clearance sidewise: 200 mm p.3 ↗

Type Code Decoder

Position Token Meaning
1-2 p.1 ↗ MK Series: dynamic climate chamber
3-6 p.1 ↗ 1020 Model size (interior volume class, 991 L)
7-9 p.1 ↗ CO₂ Refrigerant: natural CO₂ (R744)
10-14 p.3 ↗ 400V Mains variant: 400 V 3~/N/PE 50 Hz (alternative 480V = 480 V 3~/N/PE 60 Hz)

Ordering Data

Ordering Code Part No. Variant / Code S'applique à Note
MK1020CO2-400V p.1 ↗ 9020-0527 400 V 3~/N/PE 50 Hz, standard version CEE 32 / 6 H plug 5-p
MK1020CO2-480V p.2 ↗ 9020-0529 480 V 3~/N/PE 60 Hz, standard version NEMA L22-20P plug