Induztr
Résumé technique Visionneuse de documents Modèles associés

Build Consistency into Your Lab's Workflow

Sommaire

  1. Overview pp. 1-3
    Introduces consistent sample quality assessment and complete workflow solution
  2. Config. pp. 4-5
    Lists instrument models and options for different throughput needs
  3. Spec pp. 6-7
    Describes quality metrics and automated electrophoresis analysis applications
  4. Spec p. 8
    Covers oligonucleotide purity analysis workflow and system capabilities
  5. Spec p. 9
    Describes protein analysis with the ProteoAnalyzer system
  6. Services p. 10
    Explains protection plans and services for sample QC instruments
  7. Ordering pp. 11-12
    Lists kits and reagents for automated electrophoresis systems
  8. p. 4 table, 10 rows
  9. p. 10 table, 7 rows

Instrument Options for a Variety of Nucleic Acid and Protein Applications

TapeStation SystemsFragment Analyzer SystemsFemto Pulse SystemProteoAnalyzer SystemZAG System
DNA applications
RNA applications
FFPE RNA
IVT RNA
Total prokaryotic and eukaryotic RNA
Small RNA
MicroRNA
mRNA
Plant RNA
Protein applications

На странице отмечены галочки (), но их принадлежность к конкретным ячейкам по извлечённому тексту однозначно не восстанавливается; в таблице оставлены пустые ячейки.

Agilent CrossLab services for automated electrophoresis instruments

Fragment Analyzer SystemFemto Pulse SystemProteoAnalyzer SystemZAG DNA Analyzer SystemOligo Pro II System4150 and 4200 TapeStation Systems
IE Preferred/RTAOnsiteOnsiteOnsite
Repair Type
Extended Warranty
CrossLab Service Plans
Preventive Maintenance
Compliance (IQ/OQ)
Enhanced Extended WarrantyOnsiteOnsite

IE = Instrument Exchange; RTA = Return to Agilent

Engineering Facts

12 facts · every claim linked to a page
Selection

The portfolio covers ultra-low to ultra-high throughput, so instrument choice should be matched to the lab's sample capacity.

Throughput class determines which instrument model fits the lab's workload.

Source
“If your lab’s sample capacity is ultra-low, medium, or ultra-high, Agilent has the sample quality control and fragment analysis solution that fits your need.”
Selection

Oligo Pro II is the specialized option for ssDNA/ssRNA oligonucleotide purity work, not a general nucleic acid QC instrument.

Prevents selecting a general fragment analyzer for oligonucleotide purity applications.

Source
“It provides high-resolution separations and direct detection of both single-stranded DNA (ssDNA) and single-stranded RNA (ssRNA) oligonucleotides.”
Selection

Oligo Pro II throughput scales via 12, 24, or 96 capillary arrays, which must be chosen at selection.

Capillary array configuration defines the instrument's capacity and must be specified.

Source
“12, 24, or 96 capillary arrays provide for throughput scalability”
Selection

Oligo Pro II achieves n-1 resolution only through 60 nt, limiting its use for longer oligonucleotides.

Defines the application range and prevents over-expecting resolution beyond 60 nt.

Source
“n–1 resolution through 60 nt”
Performance

ProteoAnalyzer separates 12 samples in as little as 30 minutes, replacing manual SDS-PAGE steps.

Gives the throughput/time benchmark needed to justify replacing SDS-PAGE.

Source
“Able to separate 12 samples in as little as 30 minutes”
Operation

ProteoAnalyzer automates separation, capillary rejuvenation, and data processing, reducing manual intervention.

Automation level affects labor requirements and operating procedures.

Source
“Automated separation, capillary rejuvenation, and data processing”
Operation

TapeStation uses ready-to-use ScreenTape devices, minimizing hands-on time and simplifying operation.

Consumable format drives operator training and daily workflow design.

Source
“Ready-to-use consumables ensure simple operation with minimal hands-on time.”
Selection

Quality metrics (GQN, DIN, RINe, DV200, RQN, %cfDNA) are available only on certain systems; Oligo Pro II, ZAG, and ProteoAnalyzer do not offer them.

Prevents selecting an instrument that cannot report the required QC metric.

Source
“The Agilent Oligo Pro II, ZAG and ProteoAnalyzer systems do not offer quality metrics.”
Maintenance

CrossLab service plans include preventive maintenance, compliance IQ/OQ, and repair options for the instruments.

Service coverage must be planned at installation to protect uptime and compliance.

Source
“Maximize uptime, ensure instrument compliance, and control your service costs with Agilent CrossLab services for your automated electrophoresis instruments.”
Conformité

IQ/OQ compliance service is offered as part of CrossLab service plans.

Regulated labs need IQ/OQ documentation available for installation qualification.

Source
“Compliance (IQ/OQ)”
Safety

The portfolio is for research use only and must not be used for diagnostic procedures.

Restricts deployment to research settings and affects regulatory classification.

Source
“For Research Use Only. Not for use in diagnostic procedures.”
Selection

Application-specific kits and reagents are designed per instrument system, so consumables must match the chosen platform.

Consumable compatibility must be verified against the selected instrument.

Source
“Application-specific kits and reagents have been designed for each of the automated electrophoresis systems.”