Technical Data Sheet — 2BH1800 HT vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Hoja de datos 2BH1 800-2: soplador de canal lateral G-BH 1 N HT con motores IE3, 3~ 50/60 Hz, IP55, clase de aislamiento F, UL 1450 y CAN/CSA C22.2 No. 68-09 (certificado E225239). Cubre los números de tipo 1 y 2 con números de pedido 2BH1800-2AK11, -2AK21, -2AK16, -2AK26, -2AQ13, -2AQ23, -2AQ17, -2AQ27 y variantes de motor con tensión alternativa 2BH1…-2.□.□.
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Rated frequency | 50/60 Hz p.2 ↗ | 2BH1800-2AK11 |
| Voltage | 190-210 Δ / 380-480 Y V p.2 ↗ | 2BH1800-2AK11, 50/60 Hz |
| Current | 22,0 Δ / 11,0 Y A p.2 ↗ | 2BH1800-2AK11, 60 Hz |
| Power | 5,1 kW p.2 ↗ | 2BH1800-2AK11, 50 Hz |
| Power | 5,8 kW p.2 ↗ | 2BH1800-2AK11, 60 Hz |
| Max. differential pressure, vacuum | -280 mbar p.2 ↗ | 2BH1800-2AK11, 50 Hz |
| Max. differential pressure, pressure | 260 mbar p.2 ↗ | 2BH1800-2AK11, 50 Hz |
| Max. differential pressure, vacuum | -250 mbar p.2 ↗ | 2BH1800-2AK11, 60 Hz |
| Max. differential pressure, pressure | 230 mbar p.2 ↗ | 2BH1800-2AK11, 60 Hz |
| Sound pressure level | 75 dB(A) p.2 ↗ | 2BH1800-2AK11, 50 Hz |
| Sound pressure level | 77 dB(A) p.2 ↗ | 2BH1800-2AK11, 60 Hz |
| Weight approx. | 131 kg p.2 ↗ | 2BH1800-2AK11 |
| Efficiency class | IE3 p.2 ↗ | 2BH1800-2AK11, 50 Hz |
| Power | 6,9 kW p.2 ↗ | 2BH1800-2AK21, 50 Hz |
| Power | 7,9 kW p.2 ↗ | 2BH1800-2AK21, 60 Hz |
| Max. differential pressure, vacuum | -280 mbar p.2 ↗ | 2BH1800-2AK21, 50 Hz |
| Max. differential pressure, pressure | 330 mbar p.2 ↗ | 2BH1800-2AK21, 50 Hz |
| Sound pressure level | 76 dB(A) p.2 ↗ | 2BH1800-2AK21, 50 Hz |
| Weight approx. | 143 kg p.2 ↗ | 2BH1800-2AK21 |
| Protection category | IP55 p.2 ↗ | all variants |
| Insulation material class | F p.2 ↗ | all variants |
Operating Limits
- Max. suction/ambient temperature for stated total pressure differences: 25 °C p.1 ↗
- Performance curve reference air temperature: 15 °C p.1 ↗
- Performance curve reference atmospheric pressure: 1013 mbar p.1 ↗
- Performance curve tolerance: ± 10 % p.1 ↗
- Protection category: IP55 p.2 ↗
- Insulation material class: F p.2 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-6 p.2 ↗ | 2BH180 | Type series 2BH1, size 800 |
| placeholder □ (field 1) p.2 ↗ | K / 6 | Alternate-voltage motor option: K = 200 V YY / 230/400 V Y; 6 = 475-525 V Y / 550-600 V Y |
| placeholder □ (field 2) p.2 ↗ | 1 / 6 | Alternate-voltage motor option: 1 = 400 V Δ / 690 V Y; 6 = 460 V Δ |
Ordering Data
| Ordering Code | Part No. | Variant / Code | S'applique à | Note |
|---|---|---|---|---|
| 2BH1800-2AK11 p.2 ↗ | 2BH1800-2AK11 | Type No. 1, 50/60 Hz, 190-210 Δ / 380-480 Y | IE3, 131 kg | |
| 2BH1800-2AK21 p.2 ↗ | 2BH1800-2AK21 | Type No. 2, 50/60 Hz, 190-210 Δ / 380-420 Y | IE3, 143 kg | |
| 2BH1800-2AK16 p.2 ↗ | 2BH1800-2AK16 | Type No. 1, 50/60 Hz, 220-240 Δ / 380-420 Y | IE3, 131 kg | |
| 2BH1800-2AK26 p.2 ↗ | 2BH1800-2AK26 | Type No. 2, 50/60 Hz, 220-240 Δ / 380-420 Y | IE3, 143 kg | |
| 2BH1800-2AQ13 p.2 ↗ | 2BH1800-2AQ13 | Type No. 1, 50/60 Hz, 500 Y | IE3, 131 kg | |
| 2BH1800-2AQ23 p.2 ↗ | 2BH1800-2AQ23 | Type No. 2, 50/60 Hz, 500 Y | IE3, 143 kg | |
| 2BH1800-2AQ17 p.2 ↗ | 2BH1800-2AQ17 | Type No. 1, 50/60 Hz, 380-420 Δ / 660-725 Y | IE3, 131 kg | |
| 2BH1800-2AQ27 p.2 ↗ | 2BH1800-2AQ27 | Type No. 2, 50/60 Hz, 380-420 Δ / 660-725 Y | IE3, 143 kg |