| Parameter | Value | Condition |
|---|---|---|
| Rated frequency | 50 Hz p.2 ↗ | 2BH1830-2AK11, size 1 |
| Voltage | 190-210 V p.2 ↗ | 2BH1830-2AK11, 50 Hz, delta |
| Current | 19,4 A p.2 ↗ | 2BH1830-2AK11, 50 Hz, delta |
| Power | 5,1 kW p.2 ↗ | 2BH1830-2AK11, 50 Hz |
| Vacuum | -200 mbar p.2 ↗ | 2BH1830-2AK11, 50 Hz |
| Pressure | 180 mbar p.2 ↗ | 2BH1830-2AK11, 50 Hz |
| Sound pressure level | 71 dB(A) p.2 ↗ | 2BH1830-2AK11, 50 Hz |
| Efficiency class | IE3 p.2 ↗ | 2BH1830-2AK11, 50 Hz |
| Weight approx. | 133 kg p.2 ↗ | 2BH1830-2AK11 |
| Rated frequency | 60 Hz p.2 ↗ | 2BH1830-2AK11, 60 Hz |
| Voltage | 190-210 / 380-480 V p.2 ↗ | 2BH1830-2AK11, 60 Hz, YY/Y |
| Current | 22,0 / 11,0 A p.2 ↗ | 2BH1830-2AK11, 60 Hz, YY/Y |
| Power | 5,8 kW p.2 ↗ | 2BH1830-2AK11, 60 Hz |
| Vacuum | -160 mbar p.2 ↗ | 2BH1830-2AK11, 60 Hz |
| Pressure | 130 mbar p.2 ↗ | 2BH1830-2AK11, 60 Hz |
| Sound pressure level | 75 dB(A) p.2 ↗ | 2BH1830-2AK11, 60 Hz |
| Power | 6,9 kW p.2 ↗ | 2BH1830-2AK21, 50 Hz |
| Vacuum | -200 mbar p.2 ↗ | 2BH1830-2AK21, 50 Hz |
| Pressure | 200 mbar p.2 ↗ | 2BH1830-2AK21, 50 Hz |
| Weight approx. | 145 kg p.2 ↗ | 2BH1830-2AK21 |
| Power | 7,9 kW p.2 ↗ | 2BH1830-2AK21, 60 Hz |
| Vacuum | -260 mbar p.2 ↗ | 2BH1830-2AK21, 60 Hz |
| Pressure | 230 mbar p.2 ↗ | 2BH1830-2AK21, 60 Hz |
| Protection category | IP 55 p.1 ↗ | standard motors |
| Insulation class | F p.1 ↗ | standard motors |
Operating Limits
- Max ambient / suction temperature for performance curves: 25 °C p.1 ↗
- Voltage tolerance for three phase motors: +/-10 % p.2 ↗
- Frequency tolerance: +/-2 % max p.2 ↗
- Max converter input voltage for standard motor insulation: 500 V p.2 ↗
- Protection category: IP 55 p.1 ↗
- Insulation class: F p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-4 p.2 ↗ | 2BH1 | Series: side channel blower |
| 5-8 p.2 ↗ | 830-2 | Size / model designation |
| 9-10 p.2 ↗ | AK / AQ | Motor / voltage variant group |
| 11-12 p.2 ↗ | 11 / 21 / 16 / 26 / 13 / 23 / 17 / 27 | Specific variant (size 1 or 2, voltage code) |
| field 3 p.2 ↗ | K | Motor for alternate voltages, 200 V YY / 230 V delta / 400 V Y |
| field 3 p.2 ↗ | Q | Motor for alternate voltages, 475-525 V Y / 550-600 V Y |
| field 3 p.2 ↗ | 6 | Motor for alternate voltages, 400 V delta / 690 V Y |
| field 3 p.2 ↗ | 1 | Motor for alternate voltages, 460 V delta |
Ordering Data
| Ordering Code | Part No. | Variant / Code | S'applique à | Note |
|---|---|---|---|---|
| 2BH1830-2AK11 p.2 ↗ | 2BH1830-2AK11 | 50 Hz, 190-210 V delta; 60 Hz, 190-210 V YY / 380-480 V Y | Size 1, IE3 | |
| 2BH1830-2AK21 p.2 ↗ | 2BH1830-2AK21 | 50 Hz, 190-210 V delta; 60 Hz, 190-210 V YY / 380-420 V Y | Size 2, IE3 | |
| 2BH1830-2AK16 p.2 ↗ | 2BH1830-2AK16 | 50 Hz, 220-240 V delta / 380-420 V Y; 60 Hz, 220-240 V YY / 440-480 V Y | Size 1, IE3 | |
| 2BH1830-2AK26 p.2 ↗ | 2BH1830-2AK26 | 50 Hz, 220-240 V delta / 380-420 V Y; 60 Hz, 220-240 V YY / 440-480 V Y | Size 2, IE3 | |
| 2BH1830-2AQ13 p.2 ↗ | 2BH1830-2AQ13 | 50 Hz, 500 V Y; 60 Hz, 575 V Y | Size 1, IE3 | |
| 2BH1830-2AQ23 p.2 ↗ | 2BH1830-2AQ23 | 50 Hz, 500 V Y; 60 Hz, 575 V Y | Size 2, IE3 | |
| 2BH1830-2AQ17 p.2 ↗ | 2BH1830-2AQ17 | 50 Hz, 380-420 V delta / 660-725 V Y; 60 Hz, 440-480 V delta | Size 1, IE3 | |
| 2BH1830-2AQ27 p.2 ↗ | 2BH1830-2AQ27 | 50 Hz, 380-420 V delta / 660-725 V Y; 60 Hz, 440-480 V delta | Size 2, IE3 |