Technical Data Sheet — G-BH2 2BH20540-2 ATEX vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Hoja de datos 2BH2 0540-2, soplador de canal lateral en configuración ATEX (G-BH2 N), versiones de 50 Hz y 60 Hz, categorías ATEX 3GD y 3/2D como máquinas de tensión fija; 3/2G disponible únicamente en versiones de 50 Hz o 60 Hz.
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Rated voltage | 230 ∆/ 400 Y V p.2 ↗ | 2BH2 0540-2, 50 Hz |
| Rated current | 35,0 ∆/ 20,0 Y A p.2 ↗ | 2BH2 0540-2, 50 Hz |
| Power | 11,0 kW p.2 ↗ | 2BH2 0540-2, 50 Hz |
| Max. differential vacuum | -390 mbar p.2 ↗ | 2BH2 0540-2, 50 Hz |
| Max. differential pressure | 580 mbar p.2 ↗ | 2BH2 0540-2, 50 Hz |
| Sound pressure level | 71 dB(A) p.2 ↗ | 2BH2 0540-2, 50 Hz |
| Weight | 152 kg p.2 ↗ | 2BH2 0540-2, 50 Hz |
| Degree of protection | IP55 p.2 ↗ | 2BH2 0540-2 |
| ATEX category | 3GD p.2 ↗ | 2BH2 0540-2 |
| Rated voltage | 460 Y V p.2 ↗ | 2BH2 0540-2, 60 Hz |
| Rated current | 19,5 Y A p.2 ↗ | 2BH2 0540-2, 60 Hz |
| Power | 12,6 kW p.2 ↗ | 2BH2 0540-2, 60 Hz |
| Max. differential vacuum | -390 mbar p.2 ↗ | 2BH2 0540-2, 60 Hz |
| Max. differential pressure | 530 mbar p.2 ↗ | 2BH2 0540-2, 60 Hz |
| Sound pressure level | 76 dB(A) p.2 ↗ | 2BH2 0540-2, 60 Hz |
Operating Limits
- Max. ambient / suction temperature for stated total pressure differences: 25 °C p.1 ↗
- Performance curve tolerance: ± 10 % p.1 ↗
- Sound pressure level tolerance: ±3 dB(A) p.2 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-4 p.2 ↗ | 2BH2 | Series / type family (side channel blower G-BH2 N) |
| 5-8 p.2 ↗ | 0540 | Size designation |
| 9-10 p.2 ↗ | -2 | Variant / stage designation |
| field 1 p.2 ↗ | AADP1 | Motor / configuration code |
| field 2 p.2 ↗ | BA | Configuration code |