Technical Data Sheet — G-BH2 2BH20540-3 side channel blower (EN)
Technical Reference Summary
Covered Models & Document Scope
Hoja de datos 2BH2 0540-3: soplador de canal lateral con convertidor de frecuencia integrado (VFD), tipo 2BH2 0540-3, variantes 2BH20540-3AA3P6-BA (20.5 kW) y 2BH20540-3AA3Q6-BA (25.0 kW), 380 V Y / 400 V Δ, 85 Hz, con VFD integrado 3~ 400 V -15%…480 V +10%, 50/60 Hz ±6%, IP55, UL 1450; también enumera convertidores de frecuencia externos compatibles 2FC4… y accesorios.
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Rated frequency | 85 Hz p.2 ↗ | 2BH2 0540-3 |
| Voltage | 380 V p.2 ↗ | 2BH2 0540-3, Y connection |
| Voltage | 400 V p.2 ↗ | 2BH2 0540-3, Δ connection |
| Current | 41.0 A p.2 ↗ | 2BH2 0540-3, 380 V Y, 20.5 kW |
| Current | 48.0 A p.2 ↗ | 2BH2 0540-3, 380 V Y, 25.0 kW |
| Current | 39.5 A p.2 ↗ | 2BH2 0540-3, 400 V Δ, 20.5 kW |
| Current | 53.7 A p.2 ↗ | 2BH2 0540-3, 400 V Δ, 28.8 kW |
| Current | 65.3 A p.2 ↗ | 2BH2 0540-3, 400 V, 35.5 kW |
| Power | 20.5 kW p.2 ↗ | 2BH2 0540-3, 380 V Y |
| Power | 25.0 kW p.2 ↗ | 2BH2 0540-3, 380 V Y |
| Power | 20.5 kW p.2 ↗ | 2BH2 0540-3, 400 V Δ |
| Power | 28.8 kW p.2 ↗ | 2BH2 0540-3, 400 V Δ |
| Power | 35.5 kW p.2 ↗ | 2BH2 0540-3, 400 V |
| Max. differential pressure vacuum | -500 mbar p.2 ↗ | 2BH2 0540-3, 85 Hz |
| Max. differential pressure pressure | 130 mbar p.2 ↗ | 2BH2 0540-3, 20.5 kW, 85 Hz |
| Max. differential pressure pressure | 350 mbar p.2 ↗ | 2BH2 0540-3, 25.0 kW, 85 Hz |
| Max. differential pressure pressure | 520 mbar p.2 ↗ | 2BH2 0540-3, 400 V Δ, 28.8 kW, 85 Hz |
| Max. differential pressure pressure | 730 mbar p.2 ↗ | 2BH2 0540-3, 400 V, 35.5 kW, 85 Hz |
| Sound pressure level | 79/80 dB(A) p.2 ↗ | 2BH2 0540-3, 50 Hz / 60 Hz |
| Weight | 180 kg p.2 ↗ | 2BH2 0540-3, 20.5 kW |
| Weight | 182 kg p.2 ↗ | 2BH2 0540-3, 25.0 kW |
| Protection class | IP55 p.2 ↗ | 2BH2 0540-3, integrated VFD |
| Insulation material class | F p.2 ↗ | 2BH2 0540-3 |
| Rated mains voltage (VFD) | 3~ 400 V -15% … 480 V +10% V p.2 ↗ | Integrated VFD |
| Mains frequency (VFD) | 50/60 Hz p.2 ↗ | Integrated VFD, ±6% |
Operating Limits
- Max. ambient / suction temperature for stated pressure differences: 25 °C p.1 ↗
- Performance curve reference air temperature: 15 °C p.1 ↗
- Performance curve reference atmospheric pressure: 1013 mbar p.1 ↗
- Performance tolerance: ±10 % p.1 ↗
- Minimum pulse frequency of frequency converter: 4 kHz p.1 ↗
- Rated voltage/frequency set point: 345 V / 87 Hz p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-4 p.2 ↗ | 2BH2 | Series: side channel blower G-BH2 |
| 5-8 p.2 ↗ | 0540 | Size |
| 9-10 p.2 ↗ | -3 | Version |
| 11-13 p.2 ↗ | AA3 | Motor / connection variant |
| 16-17 p.2 ↗ | -BA | Execution suffix |
| VFD type field p.2 ↗ | 2FC4152-1 □ □00 … 2FC4223-1 □ □00 | External frequency converter type; □ = option field |
Ordering Data
| Ordering Code | Part No. | Variant / Code | S'applique à | Note |
|---|---|---|---|---|
| 2BH20540-3AA3P6-BA p.2 ↗ | 2BH20540-3AA3P6-BA | 380 V Y, 85 Hz, 20.5 kW | Integrated VFD | |
| 2BH20540-3AA3Q6-BA p.2 ↗ | 2BH20540-3AA3Q6-BA | 380 V Y, 85 Hz, 25.0 kW | Integrated VFD | |
| 2BH20540-3AAKP6-BA p.2 ↗ | 2BH20540-3AAKP6-BA | 380 V Y, 85 Hz, 20.5 kW | Integrated VFD, footnote 3 |