Technical Data Sheet — G-BH7 2BH7310 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Ficha técnica 2BH7 310: soplador de canal lateral con convertidor de frecuencia integrado (VFD), tipo 2BH7 310. Variantes: 3~ 400 V -15%…480 V +10%, 50/60 Hz ±6%, termistor (PTC), IP55, UL 1450; tipos de VFD A–K (2FC4xxx-1□□00); opciones de pedido G17 (ventilador accionado por separado) y G5 (VFD para montaje en pared).

Technical Data

Parameter Value Condition
Rated motor voltage 400 V p.2 ↗ 2BH7 310, 50 Hz, U
Rated motor current 5,2 A p.2 ↗ 2BH7 310, 50 Hz, U
Rated motor power 2,6 kW p.2 ↗ 2BH7 310, 50 Hz, U
Max. differential pressure, vacuum -420 mbar p.2 ↗ 2BH7 310, 50 Hz, U
Max. differential pressure, pressure 350 mbar p.2 ↗ 2BH7 310, 50 Hz, U
Sound pressure level 73 dB(A) p.2 ↗ 2BH7 310, 50 Hz, U
Weight 29 kg p.2 ↗ 2BH7 310, 50 Hz, U
Rated motor voltage 380 V p.2 ↗ 2BH7 310, 87 Hz, U
Rated motor current 4,8 A p.2 ↗ 2BH7 310, 87 Hz, U
Rated motor power 2,3 kW p.2 ↗ 2BH7 310, 87 Hz, U
Max. differential pressure, vacuum -420 mbar p.2 ↗ 2BH7 310, 87 Hz, U
Max. differential pressure, pressure 420 mbar p.2 ↗ 2BH7 310, 87 Hz, U
Sound pressure level 73 dB(A) p.2 ↗ 2BH7 310, 87 Hz, U
Weight 29 kg p.2 ↗ 2BH7 310, 87 Hz, U
Rated motor voltage 400 V p.2 ↗ 2BH7 310, 87 Hz, D
Rated motor current 3,45 A p.2 ↗ 2BH7 310, 87 Hz, D
Rated motor power 1,6 kW p.2 ↗ 2BH7 310, 87 Hz, D
Max. differential pressure, vacuum -330 mbar p.2 ↗ 2BH7 310, 87 Hz, D
Max. differential pressure, pressure 290 mbar p.2 ↗ 2BH7 310, 87 Hz, D
Sound pressure level 73 dB(A) p.2 ↗ 2BH7 310, 87 Hz, D
Rated mains voltage (VFD) 400 V p.2 ↗ VFD type A, 2FC4152-1□□00
Max. motor current (VFD) 4,0 A p.2 ↗ VFD type A, 2FC4152-1□□00
Typical motor power (VFD) 1,5 kW p.2 ↗ VFD type A, 2FC4152-1□□00
Fuse (VFD) 10 A p.2 ↗ VFD type A, 2FC4152-1□□00
Weight (VFD) 3,9 kg p.2 ↗ VFD type A, 2FC4152-1□□00

Operating Limits

  • Max. ambient/suction temperature for stated pressure differences: 25 °C p.1 ↗
  • Performance curve tolerance: ±10 % p.1 ↗
  • VFD rated mains voltage range: 400 V -15% … 480 V +10% p.2 ↗
  • VFD mains frequency tolerance: 50/60 Hz ±6% p.2 ↗
  • Minimum mains voltage for frequency converters: 380 V p.1 ↗
  • Minimum pulse frequency: 4 kHz p.1 ↗

Type Code Decoder

Position Token Meaning
1-6 p.2 ↗ 2BH731 Type/size designation: side channel blower 2BH7, size 310
8-9 p.2 ↗ 0A Motor/voltage variant field (0A = standard motor variant)
10-12 p.2 ↗ 341 / 346 / K36 / K46 / K56 Motor winding / voltage connection variant (U or D) and VFD type letter (A, B, C)
VFD field 1 p.2 ↗ A–K VFD type letter (A, B, C, D, E, F, G, H, J, K) selecting the frequency converter rating
VFD field 2-3 p.2 ↗ □□ Placeholder for VFD option/variant code (e.g. 00)

Ordering Data

Ordering Code Part No. Variant / Code S'applique à Note
2BH7310-0A341-1 p.2 ↗ 2BH7310-0A341-1 B 50 Hz, 400 V U, VFD type B Rated current 5,2 A, power 2,6 kW
2BH7310-0A346-1 p.2 ↗ 2BH7310-0A346-1 B 87 Hz, 380 V U, VFD type B Rated current 4,8 A, power 2,3 kW
2BH7310-0AK36-1 p.2 ↗ 2BH7310-0AK36-1 A 87 Hz, 400 V D, VFD type A Rated current 3,45 A, power 1,6 kW; footnote 3)
2BH7310-0AK46-1 p.2 ↗ 2BH7310-0AK46-1 B 87 Hz, 400 V D, VFD type B Rated current 4,6 A, power 2,3 kW; footnote 3)
2BH7310-0AK56-1 p.2 ↗ 2BH7310-0AK56-1 C 87 Hz, 400 V D, VFD type C Rated current 5,8 A, power 2,9 kW; footnote 3)
2FC4402-1 p.2 ↗ 2FC4402-1 D VFD type D, 400 V, 50/60 Hz Integrated VFD, IP55