Induztr
Résumé technique Visionneuse de documents Modèles associés

Technical Data Sheet — G-BH7 2BH7410 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Hoja de datos 2BH7 410 (serie G-BH7 e): soplante de canal lateral con convertidor de frecuencia integrado, variantes 2BH7410-0A3xx-1 (100 Hz, 400 V) y 2BH7410-0A3x6-1 (87 Hz, 380 V), además de variantes 2BH7410-0AKx6-1 para funcionamiento con convertidor de frecuencia externo (37/50/60 Hz); convertidores de frecuencia correspondientes 2FC4xxx-1□□00 (tamaños A–K) y accesorios (terminal manual MMI, cable adaptador USB, sensores de presión/vacío).

Technical Data

Parameter Value Condition
Rated frequency 100 Hz p.2 ↗ 2BH7410-0A311-1
Rated voltage 400 V p.2 ↗ 2BH7410-0A311-1
Rated current 5,2 A p.2 ↗ 2BH7410-0A311-1
Rated motor power 2,6 kW p.2 ↗ 2BH7410-0A311-1
Max. differential pressure, vacuum -230 mbar p.2 ↗ 2BH7410-0A311-1
Max. differential pressure, pressure 220 mbar p.2 ↗ 2BH7410-0A311-1
Sound pressure level 73 dB(A) p.2 ↗ 2BH7410-0A311-1
Weight 33 kg p.2 ↗ 2BH7410-0A311-1
Rated current 6,5 A p.2 ↗ 2BH7410-0A321-1
Rated motor power 3,5 kW p.2 ↗ 2BH7410-0A321-1
Max. differential pressure, vacuum -390 mbar p.2 ↗ 2BH7410-0A321-1
Max. differential pressure, pressure 380 mbar p.2 ↗ 2BH7410-0A321-1
Sound pressure level 77 dB(A) p.2 ↗ 2BH7410-0A321-1
Weight 36 kg p.2 ↗ 2BH7410-0A321-1
Rated current 9,5 A p.2 ↗ 2BH7410-0A331-1
Rated motor power 5,0 kW p.2 ↗ 2BH7410-0A331-1
Max. differential pressure, vacuum -410 mbar p.2 ↗ 2BH7410-0A331-1
Max. differential pressure, pressure 650 mbar p.2 ↗ 2BH7410-0A331-1
Sound pressure level 77 dB(A) p.2 ↗ 2BH7410-0A331-1
Weight 41 kg p.2 ↗ 2BH7410-0A331-1
Rated frequency 87 Hz p.2 ↗ 2BH7410-0A316-1
Rated voltage 380 V p.2 ↗ 2BH7410-0A316-1
Rated current 4,8 A p.2 ↗ 2BH7410-0A316-1
Rated motor power 2,3 kW p.2 ↗ 2BH7410-0A316-1
Max. differential pressure, vacuum -360 mbar p.2 ↗ 2BH7410-0A316-1

Operating Limits

  • Max. suction and ambient temperature for stated total pressure differences: 25 °C p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Reference air temperature for performance curves: 15 °C p.1 ↗
  • Reference atmospheric pressure for performance curves: 1013 mbar p.1 ↗
  • Minimum pulse frequency for frequency converter operation: 4 kHz p.1 ↗
  • Rated voltage/frequency set point: 345 V / 87 Hz p.1 ↗

Type Code Decoder

Position Token Meaning
1-7 p.2 ↗ 2BH7410 Type/size designation: side channel blower 2BH7, size 410
8-9 p.2 ↗ 0A Series/variant prefix
13-14 p.2 ↗ -1 Design/revision suffix
converter field p.2 ↗ 2FC4xxx-1□□00 Frequency converter order code; □□ = voltage/connection option field

Ordering Data

Ordering Code Part No. Variant / Code S'applique à Note
2BH7410-0A311-1 p.2 ↗ 2BH7410-0A311-1 B 100 Hz, 400 V 2.6 kW, 33 kg
2BH7410-0A321-1 p.2 ↗ 2BH7410-0A321-1 C 100 Hz, 400 V 3.5 kW, 36 kg
2BH7410-0A331-1 p.2 ↗ 2BH7410-0A331-1 D 100 Hz, 400 V 5.0 kW, 41 kg
2BH7410-0A316-1 p.2 ↗ 2BH7410-0A316-1 B 87 Hz, 380 V 2.3 kW, 33 kg
2BH7410-0A326-1 p.2 ↗ 2BH7410-0A326-1 C 87 Hz, 380 V 2.9 kW, 36 kg
2BH7410-0A336-1 p.2 ↗ 2BH7410-0A336-1 D 87 Hz, 380 V 4.3 kW, 41 kg
2BH7410-0AK16-1 p.2 ↗ 2BH7410-0AK16-1 external converter, 37/50/60 Hz 2.3 kW, 28 kg
2BH7410-0AK26-1 p.2 ↗ 2BH7410-0AK26-1 external converter, 37/50/60 Hz 2.9 kW, 31 kg
2BH7410-0AK36-1 p.2 ↗ 2BH7410-0AK36-1 external converter, 37/50/60 Hz 4.3 kW, 36 kg