Technical Data Sheet — 2BH7620 vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Hoja de datos para el soplador de canal lateral tipo 2BH7 620-0N con motores IE3; abarca los tamaños 1, 2, 3 y las variantes de tensión NK (190-210 V / 380-420 V), NQ (220-240 V / 380-420 V, 500 V, 380-420 V / 660-725 V), funcionamiento a 50 Hz y 60 Hz, y variantes de eficiencia IE3 y NP.
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Rated voltage | 190-210 D V p.2 ↗ | 2BH7620-0NK21-2, size 1, 50 Hz |
| Rated current | 13,3 D A p.2 ↗ | 2BH7620-0NK21-2, size 1, 50 Hz |
| Power | 3,5 kW p.2 ↗ | 2BH7620-0NK21-2, size 1, 50 Hz |
| Max. differential pressure vacuum | -520 mbar p.2 ↗ | 2BH7620-0NK21-2, size 1, 50 Hz |
| Max. differential pressure pressure | 460 mbar p.2 ↗ | 2BH7620-0NK21-2, size 1, 50 Hz |
| Sound pressure level | 68 dB(A) p.2 ↗ | 2BH7620-0NK21-2, size 1, 50 Hz |
| Weight | 62 kg p.2 ↗ | 2BH7620-0NK21-2, size 1, 50 Hz |
| Efficiency class | IE3 p.2 ↗ | 2BH7620-0NK21-2, size 1, 50 Hz |
| Rated voltage | 190-210 UU / 380-420 U V p.2 ↗ | 2BH7620-0NK21-2, size 1, 60 Hz |
| Rated current | 15,2 UU / 7,6 U A p.2 ↗ | 2BH7620-0NK21-2, size 1, 60 Hz |
| Power | 4,0 kW p.2 ↗ | 2BH7620-0NK21-2, size 1, 60 Hz |
| Max. differential pressure vacuum | -470 mbar p.2 ↗ | 2BH7620-0NK21-2, size 1, 60 Hz |
| Max. differential pressure pressure | 390 mbar p.2 ↗ | 2BH7620-0NK21-2, size 1, 60 Hz |
| Sound pressure level | 72 dB(A) p.2 ↗ | 2BH7620-0NK21-2, size 1, 60 Hz |
| Rated voltage | 190-210 D V p.2 ↗ | 2BH7620-0NK41-2, size 2, 50 Hz |
| Rated current | 17,1 D A p.2 ↗ | 2BH7620-0NK41-2, size 2, 50 Hz |
| Power | 4,6 kW p.2 ↗ | 2BH7620-0NK41-2, size 2, 50 Hz |
| Max. differential pressure vacuum | -630 mbar p.2 ↗ | 2BH7620-0NK41-2, size 2, 50 Hz |
| Max. differential pressure pressure | 640 mbar p.2 ↗ | 2BH7620-0NK41-2, size 2, 50 Hz |
| Sound pressure level | 66 dB(A) p.2 ↗ | 2BH7620-0NK41-2, size 2, 50 Hz |
| Weight | 66 kg p.2 ↗ | 2BH7620-0NK41-2, size 2, 50 Hz |
| Rated voltage | 190-210 D V p.2 ↗ | 2BH7620-0NK71-2, size 3, 50 Hz |
| Rated current | 23,5 D A p.2 ↗ | 2BH7620-0NK71-2, size 3, 50 Hz |
| Power | 6,3 kW p.2 ↗ | 2BH7620-0NK71-2, size 3, 50 Hz |
| Max. differential pressure vacuum | -630 mbar p.2 ↗ | 2BH7620-0NK71-2, size 3, 50 Hz |
Operating Limits
- Max. ambient / suction temperature for stated pressure differences: 25 °C p.1 ↗
- Protection category: IP 55 p.1 ↗
- Insulation class: F p.1 ↗
- Performance curve tolerance: ± 10 % p.1 ↗
- Reference air temperature for performance curves: 15 °C p.1 ↗
- Reference atmospheric pressure for performance curves: 1013 mbar p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-4 p.2 ↗ | 2BH7 | Series / type: side channel blower |
| 5-7 p.2 ↗ | 620 | Size designation |
| 8-9 p.2 ↗ | 0N | Variant / generation code |
| 13-14 p.2 ↗ | -2 | Motor variant suffix |
| field 3 p.3 ↗ | □ | Alternate voltage motor code: K1, K6, or blank for standard |
Ordering Data
| Ordering Code | Part No. | Variant / Code | S'applique à | Note |
|---|---|---|---|---|
| 2BH7620-0NK21-2 p.2 ↗ | 2BH7620-0NK21-2 | size 1, 190-210 V, 50/60 Hz, IE3 | Standard voltage variant K | |
| 2BH7620-0NK41-2 p.2 ↗ | 2BH7620-0NK41-2 | size 2, 190-210 V, 50/60 Hz, IE3 | Standard voltage variant K | |
| 2BH7620-0NK71-2 p.2 ↗ | 2BH7620-0NK71-2 | size 3, 190-210 V, 50/60 Hz, IE3 | Standard voltage variant K | |
| 2BH7620-0NK26-2 p.2 ↗ | 2BH7620-0NK26-2 | size 1, 220-240 V / 380-420 V, 50/60 Hz, IE3 | Voltage variant K, option 6 | |
| 2BH7620-0NK46-2 p.2 ↗ | 2BH7620-0NK46-2 | size 2, 220-240 V / 380-420 V, 50/60 Hz, IE3 | Voltage variant K, option 6 | |
| 2BH7620-0NK76-2 p.2 ↗ | 2BH7620-0NK76-2 | size 3, 220-240 V / 380-420 V, 50/60 Hz, IE3 | Voltage variant K, option 6 | |
| 2BH7620-0NQ23-2 p.2 ↗ | 2BH7620-0NQ23-2 | size 1, 500 V / 575 V, 50/60 Hz, IE3/NP | Voltage variant Q | |
| 2BH7620-0NQ43-2 p.2 ↗ | 2BH7620-0NQ43-2 | size 2, 500 V / 575 V, 50/60 Hz, IE3/NP | Voltage variant Q | |
| 2BH7620-0NQ73-2 p.2 ↗ | 2BH7620-0NQ73-2 | size 3, 500 V / 575 V, 50/60 Hz, IE3/NP | Voltage variant Q | |
| 2BH7620-0NQ27-2 p.2 ↗ | 2BH7620-0NQ27-2 | size 1, 380-420 V / 660-725 V, 50/60 Hz, IE3 | Voltage variant Q, option 7 |
Modèles liés
Elmo Rietschle 2BH721
Elmo Rietschle 2BH7210
Elmo Rietschle 2BH722
Elmo Rietschle 2BH7220
Elmo Rietschle 2BH731
Elmo Rietschle 2BH7310
Elmo Rietschle 2BH732
Elmo Rietschle 2BH7320
Elmo Rietschle 2BH741
Elmo Rietschle 2BH7410
Elmo Rietschle 2BH742
Elmo Rietschle 2BH7420
Elmo Rietschle 2BH751
Elmo Rietschle 2BH7510
Elmo Rietschle 2BH752
Elmo Rietschle 2BH7520
Elmo Rietschle 2BH753
Elmo Rietschle 2BH7530
Elmo Rietschle 2BH7610
Elmo Rietschle 2BH7620
Elmo Rietschle 2BH7630