Induztr
Résumé technique Visionneuse de documents Modèles associés

Technical Data Sheet — VSI 301 vacuum pump DE/EN)

Technical Reference Summary

Covered Models & Document Scope

Bombas de vacío de tornillo S-VSI 301, secas y sin contacto; variantes 301 (01) refrigeración de flujo continuo, 301 (31) refrigeración por circulación con intercambiador de calor agua-aire, 301 (61) refrigeración por circulación con intercambiador de calor agua-agua; variantes de motor NI, NL, UL

Technical Data

Parameter Value Condition
Nominal suction capacity 300 m³/h p.1 ↗ 301 (01), 50 Hz
Nominal suction capacity 360 m³/h p.1 ↗ 301 (01), 60 Hz
Nominal suction capacity 300 m³/h p.1 ↗ 301 (31), 50 Hz
Nominal suction capacity 360 m³/h p.1 ↗ 301 (31), 60 Hz
Nominal suction capacity 300 m³/h p.1 ↗ 301 (61), 50 Hz
Nominal suction capacity 360 m³/h p.1 ↗ 301 (61), 60 Hz
Ultimate vacuum at continuous operation 0,08 mbar (abs.) p.1 ↗ 301 (01)
Ultimate vacuum at continuous operation 0,08 mbar (abs.) p.1 ↗ 301 (31)
Ultimate vacuum at continuous operation 0,08 mbar (abs.) p.1 ↗ 301 (61)
Average noise level 73 dB(A) p.1 ↗ 301 (01), 50 Hz, EN ISO 3744
Average noise level 75 dB(A) p.1 ↗ 301 (01), 60 Hz, EN ISO 3744
Average noise level 76 dB(A) p.1 ↗ 301 (31), 50 Hz, EN ISO 3744
Average noise level 78 dB(A) p.1 ↗ 301 (31), 60 Hz, EN ISO 3744
Max. weight without motor 267 kg p.1 ↗ 301 (01)
Max. weight without motor 307 kg p.1 ↗ 301 (31)
Oil capacity 1,4 (H ¦ 0,8 / H1 ¦ 0,6) l p.1 ↗ 301 (01)
Oil capacity 1,4 (H ¦ 0,8 / H1 ¦ 0,6) l p.1 ↗ 301 (31)
Oil capacity 1,4 (H ¦ 0,8 / H1 ¦ 0,6) l p.1 ↗ 301 (61)
Cooling water consumption 6,7 l/min p.1 ↗ 301 (01)
Cooling water pressure (closed circuit), min. 0,6 bar p.1 ↗ 301 (31)
Cooling water pressure (closed circuit), max. 1,2 bar p.1 ↗ 301 (31)
Cooling water pressure (closed circuit), min. 0,6 bar p.1 ↗ 301 (61)
Cooling water pressure (closed circuit), max. 1,2 bar p.1 ↗ 301 (61)
Rated voltage (circulation pump) 230 V ± 10 % (50 / 60 Hz) V p.1 ↗ 301 (31) / 301 (61), 1~
Power consumption (circulation pump) 34 W p.1 ↗ 301 (31) / 301 (61)

Operating Limits

  • Max. intake temperature (cooling water): 45 °C p.1 ↗
  • Ultimate vacuum: 0,08 mbar (abs.) p.1 ↗
  • Cooling water pressure (closed circuit), min.: 0,6 bar p.1 ↗
  • Cooling water pressure (closed circuit), max.: 1,2 bar p.1 ↗

Type Code Decoder

Position Token Meaning
1-6 p.1 ↗ S-VSI 301 Screw vacuum pump series and size

Modèles liés