Shakers Brochure Incubator Shakers Incubator Shaker Portfolio
Technical Reference Summary
Covered Models & Document Scope
Folleto de la cartera de incubadores con agitación que abarca CellXpert CS220, Innova S44i, Innova 44/44R, Innova 42/42R, Innova 40/40R y New Brunswick S41i; variantes refrigeradas (R) y no refrigeradas donde se indica.
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Capacity class | extra large p.1 ↗ | CellXpert CS220 |
| Platform size | 93 x 51 cm p.1 ↗ | CellXpert CS220 |
| Max. vessel volume | 5 L p.1 ↗ | CellXpert CS220 |
| Orbit | 2.5/5.1 cm p.1 ↗ | CellXpert CS220 |
| Temperature range | Ambient +8 °C to 60 °C °C p.1 ↗ | CellXpert CS220 |
| Speed range | 20 – 300 rpm p.1 ↗ | CellXpert CS220, 2.54 cm (1 in) orbit |
| Speed range | 20 – 250 rpm p.1 ↗ | CellXpert CS220, 5.1 cm (2 in) orbit |
| Dimensions (W × D × H) | 131.8 x 80.5 x 66.1 cm p.1 ↗ | CellXpert CS220 |
| Device weight without accessories | 237 kg p.1 ↗ | CellXpert CS220 |
| Capacity class | extra large p.1 ↗ | Innova S44i |
| Platform size | 76 × 62 cm p.1 ↗ | Innova S44i |
| Max. vessel volume | 5 L p.1 ↗ | Innova S44i |
| Orbit | 2.5/5.1 cm p.1 ↗ | Innova S44i |
| Temperature range | Incubated: 10 °C above ambient to 80 °C; Refrigerated: 20 °C below ambient (min. 4 °C) to 80 °C °C p.1 ↗ | Innova S44i |
| Speed range | 20 – 400 rpm p.1 ↗ | Innova S44i, 2.5 cm orbit |
| Speed range | 20 – 300 rpm p.1 ↗ | Innova S44i, 5.1 cm orbit |
| Dimensions (W × D × H) | 118.2 × 86.9 × 63 cm p.1 ↗ | Innova S44i |
| Device weight without accessories | 181 kg p.1 ↗ | Innova S44i, non-refrigerated |
| Device weight without accessories | 188 kg p.1 ↗ | Innova S44i, refrigerated |
| Platform size | 76 × 46 cm p.1 ↗ | Innova 44/44R |
| Speed range | 25 – 400 rpm p.1 ↗ | Innova 44/44R, 2.5 cm orbit |
| Speed range | 25 – 300 rpm p.1 ↗ | Innova 44/44R, 5.1 cm orbit or 2 stacked |
| Device weight without accessories | 238 kg p.1 ↗ | Innova 44/44R, non-refrigerated |
| Device weight without accessories | 259 kg p.1 ↗ | Innova 44/44R, refrigerated |
| Speed range | 25 – 500 rpm p.1 ↗ | Innova 40/40R, depending on load |
Operating Limits
- Temperature range CellXpert CS220: Ambient +8 °C to 60 °C p.1 ↗
- Temperature range Innova S44i / 44/44R / 42/42R: 10 °C above ambient to 80 °C (incubated); 20 °C below ambient (min. 4 °C) to 80 °C (refrigerated) p.1 ↗
- Temperature range Innova 40/40R: 10 °C above ambient to 80 °C (incubated); 15 °C below ambient (min. 4 °C) to 80 °C (refrigerated) p.1 ↗
- Temperature range New Brunswick S41i: Ambient +4 °C to 50 °C p.1 ↗
- Max. vessel volume: 3–6 L depending on model p.1 ↗