  1. Overview p. 1
    Product introduction and key features of the Minichiller 300-H OLÉ
  2. Spec p. 2
    Technical data according to DIN 12876

Engineering Facts

14 facts · every claim linked to a page
Selection

The unit uses flammable refrigerant R-290 (A3, H220), so the installation location must be assessed for flammable-refrigerant safety requirements.

Flammable refrigerant classification drives room ventilation, ignition-source and local code compliance decisions at selection and installation.

Source
“R-290 (A3, H220)”
Installation

The chiller is air-cooled with natural refrigerant and only 0.041 kg charge, so no large refrigerant volume handling is needed but airflow must be provided.

Air-cooled condensers need adequate ambient airflow; natural refrigerant limits charge and GWP obligations.

Source
“Refrigeration machine air-cooled, natural refrigerant”
Installation

The unit requires a 110-120 V single-phase 60 Hz supply drawing up to 13 A with a 16 A fuse, so the site circuit must be sized accordingly.

Supply voltage, phase and current determine the electrical connection and breaker sizing before installation.

Source
“110-120V 1~ 60Hz”
Installation

Voltage and frequency tolerances are ±5% and ±2% but must not be combined in opposite directions, so supply quality must be verified.

Out-of-tolerance supply can damage the compressor; the example clarifies which combined deviations are not allowed.

Source
“Voltage + / - 5% with a simultaneous frequency tolerance of + / - 2%”
Operation

Cooling capacity is rated at 20 °C room temperature and drops as ambient rises, so capacity must be derated for warm rooms.

Sizing at nominal capacity without ambient derating risks insufficient cooling in real installations.

Source
“If the ambient temperature rises, the cooling capacity may drop.”
Operation

The permitted ambient temperature range is 5 to 40 °C, so the unit cannot be placed in cold rooms or hot enclosures outside this band.

Ambient limits define acceptable installation locations and prevent operation outside design conditions.

Source
“max. ambient temperature 40 °C”
Selection

The plastic pump is not resistant to acetone or polyglycols, so these media must be avoided or a more resistant pump specified.

Fluid compatibility determines whether the standard pump can be used or an upgraded material is required.

Source
“The plastic pump is not resistant against acetone and polyglycols (depending on the manufacturer).”
Operation

For freeze protection water should be mixed with glysantine or ethylene glycol rather than relying on pure water.

Correct heat-transfer fluid selection prevents freezing and damage in the low-temperature range.

Source
“It is recommended that water is mixed with either glysantine or ethylene glycol for freeze protection.”
Installation

The pump connection is M16x1 male and hose connector NW12 with M16x1 sleeve nuts are included, so plumbing must match this thread.

Knowing the supplied connection hardware avoids mismatched fittings during installation.

Source
“hose connector NW12 #6087, sleeve nuts thread M16x1#6089”
Installation

The unit has IP20 protection, so it must be kept dry and protected from water ingress.

IP20 rules out washdown or wet environments and affects placement and enclosure decisions.

Source
“Degree of Protection IP20”
Operation

The unit has an autostart function after power failure, so process restart behavior must be considered for unattended operation.

Automatic restart can be desirable or hazardous depending on the connected process and must be planned.

Source
“Autostart function for power failure”
Selection

An optional factory-fitted Pt100 sensor connection allows display (not control) of process temperature, so external monitoring must be specified at order.

If process temperature monitoring is needed, it must be ordered factory-fitted and cannot control the unit.

Source
“Option: Pt100 sensor connection #10519 to display (not control)”
Conformité

The equipment is EMC Class A Group 1, so it may cause radio interference in residential environments.

Class A equipment is intended for industrial use and may require mitigation in residential or sensitive settings.

Source
“Classification (disturbance) to EN55011: Class A, Group 1”
Installation

Single/two-phase devices are supplied with a power cable and country-specific plug that must be specified at ordering.

The plug type must be declared at order to match the site's electrical outlet.

Source