Unichiller 015w Technical Data

Sommaire

  1. Overview p. 1
    Product name and model identification for the Unichiller 015w
  2. Spec p. 2
    Technical data table according to DIN 12876 standard
  3. p. 2 table, 7 rows

Technical data according to DIN 12876

ParameterValue
Power supply requirement220-240V 1~ 50Hz
max. current8,5 A
Fuse16 A
Degree of ProtectionIP20
min. ambient temperature5 °C
max. ambient temperature40 °C
from Serial-No.:S583925

Engineering Facts

14 facts · every claim linked to a page
Installation

The chiller requires cooling water inlet temperature between 5°C and 20°C, so the facility water supply must be capable of delivering within this range.

Determines whether the site's cooling water supply is compatible before purchase and installation.

Source
“This temperature control unit is designed to operate with cooling water intake temperature between 5°C and 20°C.”
Installation

If cooling water temperature can fall below the condensation point, the cooling water pipes inside the unit must be insulated.

Prevents condensation and possible damage; affects installation work and pipe insulation requirements.

Source
“When cooling water temperatures fall below the condensation point, it is essential to insulate the cooling water pipes in the unit.”
Performance

Cooling power drops and cooling water flow rate may increase as cooling water temperature rises, so performance must be derated accordingly.

Needed to correctly size the cooling water supply and predict actual cooling capacity at site conditions.

Source
“As the cooling water temperature increases, drop in the cooling power should be expected, and also an increased cooling water flow rate possible.”
Installation

The cooling water circuit contains copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM, so only compatible cooling water may be used.

Guides water quality and material compatibility checks to avoid corrosion or fouling.

Source
“Materiels used in the cooling water circuit include; copper, Stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM.”
Operation

The plastic pump is not resistant to acetone and polyglycols, so these fluids must not be used in the circuit.

Prevents chemical attack and pump failure; critical for selecting heat transfer fluid.

Source
“The plastic pump is not resistant against acetone and polyglycols (depending on the manufacturer).”
Operation

For freeze protection, water should be mixed with glysantine or ethylene glycol rather than relying on other additives.

Ensures proper low-temperature operation and avoids freezing damage.

Source
“It is recommended that water is mixed with either glysantine or ethylene glycol for freeze protection.”
Conformité

Voltage tolerance is ±5% only with simultaneous frequency tolerance of ±2%, and certain combinations are not allowed.

Must be verified against site power quality to avoid invalid supply conditions and equipment damage.

Source
“Voltage + / - 5% with a simultaneous frequency tolerance of + / - 2%”
Conformité

The unit is EMC classified as Class A, Group 1 to EN55011, which has implications for industrial electromagnetic environment.

Affects installation location and potential interference with sensitive equipment nearby.

Source
“Classification (disturbance) to EN55011: Class A, Group 1”
Installation

Single/two-phase devices are supplied with a power cable and country-specific plug that must be specified at ordering.

Ensures correct plug type is delivered and avoids rework at installation.

Source
“Single / two-phase devices (100V to 240V) --> with power cable and country-specific plug (please specify when ordering)”
Selection

The unit uses R-290 refrigerant with GHS classification A3/H220, which is flammable and requires appropriate handling.

Affects safety classification, ventilation requirements and refrigerant handling procedures.

Source
“R-290 (A3, H220)”
Installation

Minimum cooling water differential pressure is 1 bar and maximum cooling water pressure is 6 bar, defining the required supply pressure window.

Must be checked against facility water supply to ensure adequate flow without overpressure.

Source
“min. cooling water differential pressure 1 bar max. cooling water pressure 6 bar”
Selection

The pump delivers 21 l/min at 0.5 bar, which defines the achievable circulation flow at typical system backpressure.

Used to match pump capacity to the external circuit's pressure drop and required flow.

Source
“Delivery at 0,5 bar 21 l/min”
Installation

The unit requires a 16 A fuse and draws max 8.5 A at 220-240V 1~ 50Hz, so the electrical supply must be sized accordingly.

Determines electrical installation requirements and breaker sizing.

Source
“max. current 8,5 A Fuse 16 A”
Operation

The unit is rated IP20 and must operate within ambient temperature 5°C to 40°C, so it must be installed in a suitable indoor environment.

Defines environmental limits for installation location and protection against ingress.

Source
“Degree of Protection IP20 min. ambient temperature 5 °C max. ambient temperature 40 °C”