Unichiller 160Tw-H Datasheet

Sommaire

  1. Overview p. 1
    Introduces the Unichiller 160Tw-H chiller and its main features
  2. Spec pp. 1-2
    Performance, temperature, cooling capacity and dimensional data per DIN 12876
  3. p. 2 table, 18 rows
  4. p. 1 table, 33 rows

Technical data according to DIN 12876

ParameterValue
Consumption at water 15°C, flow 15°C600 l/h
Consumption at water 15°C, flow 0°C320 l/h
Consumption at water 15°C, flow -10°C133 l/h
min. cooling water differential pressure1 bar
max. cooling water pressure6 bar
min. filling capacity6,5 l
Volume of expansion10 l
Overall dimensions WxDxH **600x600x1450 mm
Net weight233 kg
sound pressure level +/- 4 dB(A)65 dB(A)
Power supply (3 Phase)400V 3~ 50Hz
max. current (3 Phase)17 A
Fuse (3 phase)3x20A
Pressure equipment categoryI
Degree of ProtectionIP20
min. ambient temperature5 °C
max. ambient temperature40 °C
from Serial-No.:S612165

** Please respect space requirements. See operating conditions at www.huber-online.com

Technical data according to DIN 12876 — Unichiller 160Tw-H (Order-No.: 3056.0005.01)

ParameterValue
Operating temperature range-20...100 °C
temperature set point / display5,7" colour Touchscreen
Internal temperature sensorPt100
Sensor external connectionPt100
Temperature stability at -10°C0,2 K
Interface digitalEthernet, USB (Host u. Device), RS232
Safety classificationIII / FL
Heating power2 kW
Cooling power at 15°C16 kW
Cooling power at 0°C9,5 kW
Cooling power at -10°C5,5 kW
Cooling power at -20°C4 kW
Refrigeration machinewater-cooled, CFC- and HCFC-free
Refrigerant (ASHRAE, GHS)R-449A (A1, H280)
Global Warming Potential (GWP)1397
Refrigerant quantity2,1 kg
CO2 equivalent2,9 t
UN-numberUN 2857
Circulation pumpC3
max. delivery96 l/min
max. delivery pressure5,6 bar
Delivery at 0,5 bar92 l/min
Delivery at 1,0 bar86 l/min
Delivery at 1,5 bar81 l/min
Delivery at 2,0 bar75 l/min
Delivery at 2,5 bar68 l/min
Delivery at 3,0 bar62 l/min
Delivery at 3,5 bar54 l/min
Delivery at 4,0 bar46 l/min
Delivery at 4,5 bar37 l/min
Delivery at 5,0 bar24 l/min
Pump connectionG1 1/4 male
Cooling water connectionG3/4 male

Engineering Facts

14 facts · every claim linked to a page
Installation

The chiller is water-cooled and requires cooling water inlet temperature between 5°C and 20°C, so the site must provide cooling water within this range.

Cooling water temperature outside this range will affect cooling capacity and may require additional measures.

Source
“This temperature control unit is designed to operate with cooling water intake temperature between 5°C and 20°C.”
Installation

If cooling water temperature falls below the condensation point, the cooling water pipes in the unit must be insulated.

Prevents condensation and corrosion on cooling water piping.

Source
“When cooling water temperatures fall below the condensation point, it is essential to insulate the cooling water pipes in the unit.”
Performance

Cooling power drops as cooling water temperature rises, and cooling water flow rate may need to increase.

Selection must account for actual site cooling water temperature to ensure sufficient cooling capacity.

Source
“As the cooling water temperature increases, drop in the cooling power should be expected, and also an increased cooling water flow rate possible.”
Installation

The cooling water circuit materials include copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM, so only suitable cooling water must be used.

Incompatible water quality can cause corrosion or fouling in the cooling circuit.

Source
“Materiels used in the cooling water circuit include; copper, Stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM. Please use suitable cooling water.”
Conformité

Voltage tolerance is ±5% with simultaneous frequency tolerance of ±2%, but combinations such as -5% voltage and +2% frequency are not allowed.

Power supply quality must be checked to avoid invalid voltage/frequency combinations that could damage the unit.

Source
“-5% voltage and +2% frequency -> not allowed!”
Installation

Three-phase devices with current consumption less than 63A are supplied with cable but without plug.

The installer must provide a suitable plug or direct connection for this 17A three-phase unit.

Source
“Three-phase devices with current consumption less than 63A --> with cable, without plug”
Safety

The unit has adjustable overtemperature protection according to DIN 12876.

Overtemperature protection must be set correctly for safe operation with external closed applications.

Source
“With adjustable overtemperature protection according to DIN 12876.”
Selection

The chiller is intended for externally closed applications.

The unit is not suitable for open bath applications; the process loop must be closed.

Source
“For externally closed applications.”
Installation

The minimum cooling water differential pressure is 1 bar and maximum cooling water pressure is 6 bar.

The cooling water supply must provide at least 1 bar differential pressure and must not exceed 6 bar.

Source
“min. cooling water differential pressure 1 bar”
Operation

The unit is rated IP20, so it must be installed in an environment protected from dust and water ingress.

IP20 limits installation locations and requires protection from moisture and dust.

Source
“Degree of Protection IP20”
Operation

The ambient temperature must be between 5°C and 40°C.

Operating outside this ambient range may affect performance and reliability.

Source
“min. ambient temperature 5 °C”
Installation

The unit requires a 400V 3~ 50Hz power supply with maximum current 17A and 3x20A fuses.

Electrical supply and protection must be sized accordingly.

Source
“Power supply (3 Phase) 400V 3~ 50Hz”
Maintenance

The refrigerant is R-449A with GWP 1397 and charge 2.1 kg, corresponding to 2.9 t CO2 equivalent.

Refrigerant handling and leak checks must follow applicable regulations for this charge and GWP.

Source
“Refrigerant quantity 2,1 kg”
Selection

The circulation pump delivers a maximum of 96 l/min at 5.6 bar, with delivery dropping at higher pressures.

Pump curve must be checked against the pressure drop of the external circuit to ensure required flow.

Source
“max. delivery 96 l/min”