Product name and general description of the Unistat T345 HT unit
Specp. 2
Technical data according to DIN 12876 standard
p. 1table, 25 rows
Technical data according to DIN 12876
Parameter
Value
Operating temperature range
65... 300 °C
Temperature stability at 70°C
0,01 K
temperature set point / display
5,7" colour Touchscreen
Resolution of display
0,01 K
Internal temperature sensor
Pt100
External sensor
Pt100
Interface digital
Ethernet, USB (Host u. Device), RS232
digital input
ECS ONE
digital output
POKO ONE
Alarm message
optic, acoustic, relay
Safety classification
III / FL
Heating power
72 kW
Cooling power at 300°C
30 kW
Circulation pump:
MK pump
max. delivery
200 l/min
max. delivery pressure
5,5 bar
Pump connection
M38x1,5 male
max. permissible kin. viscosity
50 mm²/s
Filling capacity expansion tank
56 l
Overall dimensions WxDxH **
800x1007x2200 mm
Power supply (3 Phase)
400V 3~ 50Hz
Degree of Protection
IP20
min. ambient temperature
5 °C
max. ambient temperature
40 °C
from Serial-No.:
1.0/25
** Overall dimensions WxDxH
Engineering Facts
14 facts · every claim linked to a page
Selection
The unit is a high-temperature circulator covering 65 to 300 °C, so it suits processes requiring heating up to 300 °C but not sub-ambient cooling.
Defines the process window and excludes applications needing temperatures below 65 °C.
Source
“Operating temperature range 65... 300 °C”
Performance
With 72 kW heating and 30 kW cooling at 300 °C, the unit can handle large thermal loads but requires adequate facility power and heat rejection.
Sizing the electrical supply and cooling water/heat rejection must match these capacities.
Source
“Heating power 72 kW”
Installation
The unit requires a 400 V three-phase 50 Hz supply, so the site must provide a suitable 3-phase feed.
Confirms the electrical infrastructure needed before installation.
Source
“Power supply (3 Phase) 400V 3~ 50Hz”
Installation
Three-phase devices under 63 A are delivered with cable but without a plug, so the customer must provide and fit the site plug.
Affects electrical installation planning and who supplies the plug.
Source
“Three-phase devices with current consumption less than 63A --> with cable, without plug”
Installation
Voltage and frequency tolerances are ±5% and ±2% but not simultaneously in opposite directions, so supply quality must be checked.
Prevents commissioning on a supply that would violate the allowed tolerance combination.
Source
“Voltage + / - 5% with a simultaneous frequency tolerance of + / - 2%”
Safety
Leakage current exceeds 3.5 mA, so protective earthing and RCD selection must account for high leakage.
Impacts electrical safety design and choice of residual current protection.
Source
“Attention: leakage current > 3,5mA”
Installation
Pump connections use DIN 3863 ball-socket fittings with DIN 3870 sleeve nuts, so hoses and pipework must match this standard.
Ensures correct mating fittings and avoids leaks at the M38x1.5 pump connection.
Source
“Pump connections: Bore shape Y (60°) according to DIN 3863, pipework/flexible tempering hoses: Ball socket according to DIN 3863, sleeve nut according to DIN 3870.”
Operation
The unit is rated for ambient temperatures from 5 to 40 °C, so the installation room must stay within this range.
Room conditions outside this range can affect performance and reliability.
Source
“min. ambient temperature 5 °C”
Installation
The enclosure is IP20, so it must be installed in a dry indoor location protected from water and dust ingress.
Prevents placing the unit in washdown or outdoor environments.
Source
“Degree of Protection IP20”
Selection
The pump delivers up to 200 l/min at 5.5 bar, so external circuit pressure drop must be checked against this curve.
Ensures the circulation pump can overcome the external loop resistance.
Source
“max. delivery pressure 5,5 bar”
Selection
The maximum permissible kinematic viscosity is 50 mm²/s, so the heat transfer fluid must be selected within this limit at operating temperature.
Prevents pump overload and poor circulation with overly viscous fluids.
Source
“max. permissible kin. viscosity 50 mm²/s”
Conformité
The unit is EMC Class A Group 1, so it is intended for industrial environments and may cause interference in residential areas.
Affects installation location and EMC compatibility with sensitive equipment.
Source
“Classification (disturbance) to EN55011: Class A, Group 1”
Safety
The unit has adjustable overtemperature protection per DIN 12876 and safety class III/FL, so it is suitable for flammable liquids with the appropriate setup.
Confirms built-in safety features required for unattended operation and flammable media.
Source
“With adjustable overtemperature protection according to DIN 12876.”
Maintenance
The expansion tank holds 56 l and is not thermoregulated, so fluid volume and expansion must be planned accordingly.
Determines fluid fill volume and expansion allowance for the system.