Sistemas de balance filtrada XPert (anchos nominales de 2', 3', 4', 5', 6'; versiones de 100-115 V y 230 V; con monitor de flujo de aire None, Guardian o Guardian 1000 Digital) y estaciones de balance filtrada XPert (anchos nominales de 2', 3', 4', 5', 6'; versiones de 100-115 V y 230 V; con monitor de flujo de aire None, Guardian o Guardian 1000 Digital).

Technical Data

Parameter Value Condition
Nominal width 2' ft p.11 ↗ XPert Filtered Balance System, 50/60 Hz
Overall dimensions 24.0" w x 29.0" d x 37.1" h in p.11 ↗ XPert Filtered Balance System, 2'
Interior dimensions 21.6" w x 23.4" d x 22.7" h in p.11 ↗ XPert Filtered Balance System, 2'
Electrical requirements 100-115 V p.11 ↗ XPert Filtered Balance System, 2', 50/60 Hz
Shipping weight 175/79 lbs./kg p.11 ↗ XPert Filtered Balance System, 2', no airflow monitor
Shipping weight 180/82 lbs./kg p.11 ↗ XPert Filtered Balance System, 2', Guardian airflow monitor
Total exhaust 145 CFM p.10 ↗ XPert Filtered Balance System, 2', 100 fpm, sash opening 9.4"
Sound level 53-58 dB(A) p.10 ↗ XPert Filtered Balance System, 2', 100 fpm
Total exhaust 115 CFM p.10 ↗ XPert Filtered Balance System, 2', 80 fpm
Sound level 50-55 dB(A) p.10 ↗ XPert Filtered Balance System, 2', 80 fpm
Total exhaust 85 CFM p.10 ↗ XPert Filtered Balance System, 2', 60 fpm
Sound level 48-53 dB(A) p.10 ↗ XPert Filtered Balance System, 2', 60 fpm
Nominal width 2' ft p.17 ↗ XPert Filtered Balance Station, 50/60 Hz
Overall dimensions 24.0" w x 29.0" d x 38.3" h in p.17 ↗ XPert Filtered Balance Station, 2'
Interior dimensions 21.6" w x 23.4" d x 22.7" h in p.17 ↗ XPert Filtered Balance Station, 2'
Electrical requirements 100-115 V p.17 ↗ XPert Filtered Balance Station, 2', 50/60 Hz
Shipping weight 165/75 lbs./kg p.17 ↗ XPert Filtered Balance Station, 2', no airflow monitor
Shipping weight 170/77 lbs./kg p.17 ↗ XPert Filtered Balance Station, 2', Guardian airflow monitor
Total exhaust 145 CFM p.16 ↗ XPert Filtered Balance Station, 2', 100 fpm, sash opening 9.4"
Initial static pressure 0.72 in. S.P. p.16 ↗ XPert Filtered Balance Station, 2', 100 fpm
Total exhaust 115 CFM p.16 ↗ XPert Filtered Balance Station, 2', 80 fpm
Initial static pressure 0.57 in. S.P. p.16 ↗ XPert Filtered Balance Station, 2', 80 fpm
Total exhaust 85 CFM p.16 ↗ XPert Filtered Balance Station, 2', 60 fpm
Initial static pressure 0.41 in. S.P. p.16 ↗ XPert Filtered Balance Station, 2', 60 fpm

Operating Limits

  • Face velocity range: 60-100 fpm p.10 ↗
  • Sash opening height: 9.4" or 12.0" p.10 ↗
  • Electrical requirements: 100-115 V or 230 V, 50/60 Hz p.11 ↗

Type Code Decoder

Position Token Meaning
Catalog number digit 4 p.11 ↗ 0, 3, 4, 5, 6 Nominal width: 2', 3', 4', 5', 6'
Catalog number digit 5 p.11 ↗ 0, 2, 4, 6 Model variant: 0 = standard depth/height, 2 = interior 23.4" depth, 4 = 35.5" depth, 6 = tall height
Catalog number digit 6 p.11 ↗ 0, 1, 2 Built-in airflow monitor: 0 = None, 1 = Guardian, 2 = Guardian 1000 Digital
Catalog number digit 7 p.11 ↗ 0, 1, 2 Electrical requirements: 0 = 100-115 V, 1 = 230 V, 2 = 230 V

Ordering Data

Ordering Code Part No. Variant / Code S'applique à Note
3950200 p.11 ↗ 3950200 2', 100-115 V, 50/60 Hz, no airflow monitor XPert Filtered Balance System
3950201 p.11 ↗ 3950201 2', 100-115 V, 50/60 Hz, Guardian airflow monitor XPert Filtered Balance System
3950202 p.11 ↗ 3950202 2', 100-115 V, 50/60 Hz, Guardian 1000 Digital airflow monitor XPert Filtered Balance System
3950220 p.11 ↗ 3950220 2', 230 V, 50/60 Hz, no airflow monitor XPert Filtered Balance System
3950221 p.11 ↗ 3950221 2', 230 V, 50/60 Hz, Guardian airflow monitor XPert Filtered Balance System
3950222 p.11 ↗ 3950222 2', 230 V, 50/60 Hz, Guardian 1000 Digital airflow monitor XPert Filtered Balance System
3940200 p.17 ↗ 3940200 2', 100-115 V, 50/60 Hz, no airflow monitor XPert Filtered Balance Station
3940201 p.17 ↗ 3940201 2', 100-115 V, 50/60 Hz, Guardian airflow monitor XPert Filtered Balance Station
3940202 p.17 ↗ 3940202 2', 100-115 V, 50/60 Hz, Guardian 1000 Digital airflow monitor XPert Filtered Balance Station
3940220 p.17 ↗ 3940220 2', 230 V, 50/60 Hz, no airflow monitor XPert Filtered Balance Station