TriScroll 300 Inverter

Sommaire

  1. p. 3
    Document contents listing
  2. p. 5
    Index of figures and tables
  3. Quality p. 7
    Warranty terms and conditions
  4. Procedure pp. 9-12
    Installation, operation and safety instructions
  5. Spec pp. 13-28
    Specifications, dimensions, performance and technical data
  6. Spec pp. 29-30
    Operational requirements and conditions
  7. p. 34
    Service and support contact information
  8. p. 11 table, 7 rows
  9. p. 13 table, 26 rows
  10. p. 18 table, 9 rows
  11. p. 27 table, 4 rows
  12. p. 17 table, 9 rows
  13. p. 26 table, 3 rows
  14. p. 28 table, 2 rows
  15. p. 29 table, 4 rows
  16. p. 9 table, 2 rows

Table 1 Power Cord Selection

CountryPower Cord SpecificationOrder
Europe10 A / 220-230 VAC, 2.5 m656494220
Denmark10 A / 220-230 VAC, 2.5 m656494225
Switzerland10 A / 230 VAC, 2.5 m656494235
UK/Ireland13 A / 230 VAC, 2.5 m656494250
India10 A / 220-250 VAC, 2.5 m656494245
Israel10 A / 230 VAC, 2.5 m656494230
North America10 A / 230 VAC, 2.5 m656494255

Table 3 Specifications

SpecificationTriScroll™ 300 Inverter Dry Scroll Vacuum Pump (PTS03001INV)
ModelTriScroll™ 300 Inverter Dry Scroll Vacuum Pump (PTS03001INV)
Interface dimensionsSee Figure 1 on page 6
Peak pumping speed250 l/m, 15m3/hr (8.9 cfm) See Figure 2
MediaClean air. No toxic, corrosive, explosive or particulate forming gases
Ultimate pressure (Torr)1.0 x 102 Torr (1.3 x 102 mbar)
Maximum inlet pressure1.0 atmosphere (0 psig)
Maximum continuous inlet pressure100 Torr
Maximum outlet pressure1.1 atmosphere (1.5 psig)
Inlet connectionNW25
Exhaust connectionFemale 1/4" National Pipe Thread (NW16 adapter provided)
Gas ballastFemale 1/4" National Pipe Thread (40 Micron sintered filter provided)
Ambient operating temperature5 °C to 40 °C (41 °F to 104 °F)
Storage temperature–20 °C to 60 °C (–4 °F to 140 °F)
Motor rating0.67 HP (0.5 kW)
Operating voltage50-60 Hz:200-240 VAC Single-phase / 100-120 VAC Single Phase* ±10%
Motor line current200 VAC; 5 A 240 VAC; 4.2 A
Motor thermal protectionAutomatic
Operating speed35-65 Hz Factory setting: 62 Hz, 1800 RPM
Cooling systemAir-cooled
WeightPump only: 26 kg (57 lbs) Shipping weight: 33.6 kg (74 lbs)
Noise level (per ISO 11201)Variable with frequency, 55-68 dB(A)
Vibration level at inlet (per ISO 10816-1)Variable with frequency
Main fuseType H; 10 A, 250 V (Littlefuse 0216010.HxP or equivalent)
Installation and storageInstallation category 2, indoor usage and storage
Pollution degree2
Altitude2000 m

*Inverter with P/N of S4897001 ONLY

Table 5 J2 - Serial Port

PIN #SIGNAL NAME
1+ 5 V out
2TX (RS232)
3RX (RS232)
4Spare
5GND
6A+ (RS485)
7Spare
8B- (RS485)
9Spare

Table 10 Maintenance and Tooling Kits

DescriptionContentsApplicable TriScroll ModelPart Number
Major Maintenance KitAll bearings, bearing seals, bearing lubricant, O-rings, and tip seals required to rebuild TriScroll 300 series pumps.All TriScroll 300 Series modelsPTSS0300MK
Maintenance Tool KitAll fixtures and tools required to perform any maintenance on TriScroll 300 Series pumps.All TriScroll 300 Series modelsPTSS0300TK
Tip Seal Tool KitAll tools required to change the tip seals on the TriScroll 300 Series pumps.All TriScroll 300 Series modelsPTSTSTKIT
Replacement Tip Seal SetReplacement tip seals and static O-rings for TriScroll 300 Series pumps.All TriScroll 300 Series modelsPTSS0300TS

NOTE: After tip seal replacement, the TriScroll 300 Inverter pump may require up to 24 hours run time to achieve full rotational speed.

Table 4 P1 Interlock

PIN #SIGNAL NAMEIN/OUT
1VPI relay contact 1Out
20-10 V remote controlIn
3No Connection
4Start (-) - Connect to Pin 5In
5GroundoutOut
6VPI relay contact 2Out
7No Connection
8Start (+) - Connect to Pin 9In
924 VOut

Pump operation is interlock dependent. The provided mating connector must be plugged into P1 to start the pump.

Table 9 Other Related Manuals

TitleApplicable TriScroll ModelPart Number
Tip Seal Replacement ManualAll TriScroll 300 Series models699904280
Pump Module Replacement ManualAll TriScroll 300 Series models699904285
Major Maintenance ManualAll TriScroll 300 Series models699904260

Table 11 Factory Service Options

Factory Service OptionsPart Number
Advance Exchange TriScroll 300 Pump Module OnlyEXPTS0300SC
Service/Rebuild TriScroll 300 Inverter PumpPTS0300KMA

RETURN THE COMPLETED REQUEST FOR RETURN FORM TO YOUR NEAREST LOCATION:

NORTH AMERICA:PACIFIC RIM:EUROPE:
Fax: 1 781 860 9252please visit our website for individual office information http://www.DJLOHQW.comFax: 00 39 011 9979 330
Toll Free: 800 882 7426, Option 3Fax Free: 00 800 345 345 00
vpl-ra@agilent.comToll Free: 00 800 234 234 00
vpt-customercare@agilent.com

Environmental requirements for transport and storage

ParameterRequirement
Temperature–20 °C to 60 °C (–4 °F to 140 °F)
Relative humidity0 to 95% (non-condensing)

Engineering Facts

13 facts · every claim linked to a page
Selection

The pump is only suitable for air or inert gases and must not be used for toxic, corrosive, explosive, or particulate-forming gases.

Media compatibility determines whether this pump can be selected for a given process gas.

Source
“This pump is suitable for pumping air or inert gases. The pump is not intended to pump toxic, corrosive, explosive, or particulate-forming gases.”
Installation

The pump must be connected using a high-voltage IEC-320 power cord rated for at least 10 A.

Using an undersized or incorrect cord creates a fire/electrical hazard and may void compliance.

Source
“The pump must be connected to the power supply using a high voltage IEC-320 type power cord of at least 10 A capacity.”
Installation

If an extension cord is used, it must be at least 16-gauge wire and no longer than 25 ft (7.6 m).

An undersized or too-long extension cord causes voltage drop, loss of power, and overheating.

Source
“Agilent recommends using only extension cords with a minimum of 16-gauge wire and a maximum length of 25’ (7.6 m).”
Installation

A circuit breaker of the proper capacity must be installed near the pump and marked with the on/off symbol.

Proper breaker sizing and location are required for safe disconnection and short-circuit protection.

Source
“Protect against short circuits by installing a circuit breaker of the proper capacity.”
Operation

The pump must be run at atmosphere periodically to flush out accumulated dust and debris because it has no oil to cleanse itself.

Regular atmospheric flushing prevents debris accumulation and maintains pump performance.

Source
“Run the pump periodically at atmosphere for a minute or two to flush out the pump.”
Operation

The pump requires about one hour of running with the inlet sealed to reach ultimate vacuum.

Operators should not expect ultimate pressure immediately after startup.

Source
“In order to reach ultimate vacuum, the pump must be left running for about one hour with the inlet sealed.”
Installation

A fast-acting, normally closed isolation valve is strongly recommended and must open at least 350 ms after startup and close within 250 ms after shutdown.

Proper valve timing prevents pump debris from backstreaming into the vacuum chamber.

Source
“The opening of this valve must occur 350 ms after pump startup.”
Operation

The gas ballast port should not be blocked; dry nitrogen at about 5 lpm can be used if atmospheric air ingress is undesirable.

Blocking the gas ballast can cause condensate accumulation and degrade pump performance.

Source
“Blocking of the gas ballast port is not recommended.”
Installation

The bearing purge port must be supplied with dry nitrogen at 2 psig or less and must be kept below 5 psig.

Exceeding the pressure limit can damage the bearing seals and cause leakage.

Source
“This gas supply should be maintained at 2 psig or less and must be kept below 5 psig.”
Maintenance

After tip seal replacement, the pump may require up to 24 hours of run time to achieve full rotational speed.

Maintenance planning must account for this break-in period before full performance is restored.

Source
“After tip seal replacement, the TriScroll 300 Inverter pump may require up to 24 hours run time to achieve full rotational speed.”
Performance

The pump is power-limited to 750 W; if more power is needed at the set frequency, the drive reduces output frequency (autotuning).

Understanding autotuning explains why the pump may not reach the target frequency under high load.

Source
“If the pump requires more than 750 Watts to run at the set frequency, the pump will be power limited and the output frequency will be reduced.”
Operation

Remote speed control uses a 0–10 V analog input: above 9 V gives full speed, below 1 V gives minimum speed (35 Hz).

Correct analog signal levels are needed for proper remote speed control.

Source
“Vin > 9 V: Driving frequency will be the full speed (factory set @62 Hz)”
Safety

The pump surface can exceed 55 °C (131 °F) during operation; allow cooling before maintenance.

Burn hazard requires cool-down before servicing.

Source
“If you have to perform maintenance on the pump after a considerable time in operation, allow the pump to cool as the temperature of the outer surface may be in excess of 55 °C (131 °F).”