Technical Data Sheet — G-BH7 2BH7420 side channel blower (EN)
Technical Reference Summary
Covered Models & Document Scope
Hoja de datos 2BH7 420: soplador de canal lateral con convertidor de frecuencia integrado (serie G-BH7 e). Abarca las variantes 2BH7420 a 100 Hz (400 V) y 87 Hz (380 V), además del funcionamiento a 50 Hz mediante convertidor de frecuencia (2BH7420-0AK26-1, -0AK36-1, -0AK66-1) y los convertidores de frecuencia correspondientes 2FC4xxx-1□□00.
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Rated frequency | 100 Hz p.2 ↗ | 2BH7420-0A321-1 |
| Rated voltage | 400 V p.2 ↗ | 2BH7420-0A321-1 |
| Rated motor current | 6,5 A p.2 ↗ | 2BH7420-0A321-1 |
| Rated motor power | 3,5 kW p.2 ↗ | 2BH7420-0A321-1 |
| Max. differential pressure (vacuum) | -270 mbar p.2 ↗ | 2BH7420-0A321-1 |
| Max. differential pressure (pressure) | 200 mbar p.2 ↗ | 2BH7420-0A321-1 |
| Sound pressure level | 77 dB(A) p.2 ↗ | 2BH7420-0A321-1 |
| Weight | 45 kg p.2 ↗ | 2BH7420-0A321-1 |
| Rated frequency | 100 Hz p.2 ↗ | 2BH7420-0A331-1 |
| Rated voltage | 400 V p.2 ↗ | 2BH7420-0A331-1 |
| Rated motor current | 9,5 A p.2 ↗ | 2BH7420-0A331-1 |
| Rated motor power | 5,0 kW p.2 ↗ | 2BH7420-0A331-1 |
| Max. differential pressure (vacuum) | -550 mbar p.2 ↗ | 2BH7420-0A331-1 |
| Max. differential pressure (pressure) | 450 mbar p.2 ↗ | 2BH7420-0A331-1 |
| Sound pressure level | 77 dB(A) p.2 ↗ | 2BH7420-0A331-1 |
| Weight | 50 kg p.2 ↗ | 2BH7420-0A331-1 |
| Rated frequency | 100 Hz p.2 ↗ | 2BH7420-0A361-1 |
| Rated voltage | 400 V p.2 ↗ | 2BH7420-0A361-1 |
| Rated motor current | 12,7 A p.2 ↗ | 2BH7420-0A361-1 |
| Rated motor power | 6,9 kW p.2 ↗ | 2BH7420-0A361-1 |
| Max. differential pressure (vacuum) | -580 mbar p.2 ↗ | 2BH7420-0A361-1 |
| Max. differential pressure (pressure) | 800 mbar p.2 ↗ | 2BH7420-0A361-1 |
| Sound pressure level | 80 dB(A) p.2 ↗ | 2BH7420-0A361-1 |
| Weight | 57 kg p.2 ↗ | 2BH7420-0A361-1 |
Operating Limits
- Suction and ambient temperature for stated total pressure differences: up to 25 °C p.1 ↗
- Performance curve tolerance: ± 10 % p.1 ↗
- Minimum frequency converter pulse frequency: 4 kHz p.1 ↗
- Rated voltage/frequency set point: 345 V / 87 Hz p.1 ↗
- Minimum mains voltage for frequency converters: 380 V p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-7 p.2 ↗ | 2BH7420 | Blower type/size designation |
| 8-9 p.2 ↗ | 0A | Series/variant field |
| converter field p.2 ↗ | 2FC4xxx-1□□00 | Frequency converter model; □□ = power class code (A–K) |
| converter suffix p.2 ↗ | Z = U53 | Option: PN 2 AIN / 2 AOUT / 4 DIGIN / 1 DIGOUT / 2 RELAYS / SERCOS3 interface, delivered installed |
Ordering Data
| Ordering Code | Part No. | Variant / Code | S'applique à | Note |
|---|---|---|---|---|
| 2BH7420-0A321-1 p.2 ↗ | 2BH7420-0A321-1 | C | 100 Hz, 400 V | 3.5 kW, 45 kg |
| 2BH7420-0A331-1 p.2 ↗ | 2BH7420-0A331-1 | D | 100 Hz, 400 V | 5.0 kW, 50 kg |
| 2BH7420-0A361-1 p.2 ↗ | 2BH7420-0A361-1 | E | 100 Hz, 400 V | 6.9 kW, 57 kg |
| 2BH7420-0AK26-1 p.2 ↗ | 2BH7420-0AK26-1 | C | 50 Hz via frequency converter | 3.5 kW, 40 kg |
| 2BH7420-0AK36-1 p.2 ↗ | 2BH7420-0AK36-1 | D | 50 Hz via frequency converter | 5.0 kW, 45 kg |
| 2BH7420-0AK66-1 p.2 ↗ | 2BH7420-0AK66-1 | E | 50 Hz via frequency converter | 6.9 kW, 49 kg |