Agilent Technologies 1260 Infinity II Bio-SEC System

Agilent Technologies 1260 Infinity II Bio-SEC System — Liquid chromatography with Pumping speed 0.024 m³/h.

The 1260 Infinity II Bio-SEC Multidetector System is a size-exclusion chromatography platform built around a 2.1 mm × 50 mm, 1.8 µm column and a 2 µL, 3 mm path-length flow cell, configured for bio-inert operation with tolerance to 2 M NaCl, 8 M urea, 0.5 M NaOH and 0.5 M HCl. It is distinguished within the 1260 Infinity II series by its multidetector SEC configuration and 6144-sample capacity, positioning it for high-throughput aggregate and fragment analysis of proteins and biopolymers.

Pumping speed
0.024 m³/h

Agilent Technologies GPC SEC Solutions Series — Model Comparison & Selection

Model Pumping speed, m³/hSample volume, milliliterColumn particle size, µmColumn temperature, °CColumn inner diameter, mmColumn length, m
1260 Infinity II Bio-SEC System Current 0.024—1.8—2.10.05
1260 Infinity II Bio-SEC system | Biological polymer analysis 4.8×10⁻⁵0.012.730——
1260 Infinity II Multidetector GPC/SEC System —5...500—220——
1290 Infinity II GPC/SEC system 3.6×10⁻⁶0.023354.60.25

Full specifications

Core Performance & Functional Specifications
Pumping speed 0.400 mL/min
Carryover 9 ppm
Column Particle Size 1.8 µm
Flow Cell Volume 2 µL
Sample Capacity 6144 samples
Membrane pore size mfr 0.22 μm
Salt concentration tolerance mfr 2 NaCl
Urea concentration tolerance mfr 8 urea
NaOH concentration tolerance mfr 0.5 NaOH
HCl concentration tolerance mfr 0.5 HCl
Dimensions, Weight & Mechanical Design
Column Inner Diameter 2.1 mm
Column Length 50 mm
Flow Cell Path Length 3 mm

Description

Construction and series positioning

Behavior under load and in different media

Installation, connection and control

Integration & Operating Notes

Process Limits
Do not exceed 2 M NaCl, 8 M urea, 0.5 M NaOH or 0.5 M HCl

The stated salt and chaotrope tolerances define the wetted-path compatibility envelope. Exceeding 2 M NaCl, 8 M urea, 0.5 M NaOH or 0.5 M HCl risks damage to bio-inert components and invalid SEC results; verify mobile-phase composition before each method.

Factory Specification Sheet, extra_specs
Process Limits
Use 0.22 µm filtration on all mobile phases

The 0.22 µm membrane pore size specification sets the filtration requirement for buffers and samples. Particulates above this rating can foul the 1.8 µm column and the 2 µL flow cell, so filter all phases before use.

Factory Specification Sheet, extra_specs
Maintenance
Replace the 0.22 µm filters and guard the 1.8 µm column

Because the column particle size is 1.8 µm and the flow cell volume is only 2 µL, particulate loading is the main service driver. Establish a filter-replacement interval and column guard policy to protect resolution and detector baseline.

Factory Specification Sheet, extra_specs

Selection & Integration Q&A

When should I choose this 1260 Infinity II Bio-SEC Multidetector System instead of a sibling such as the 1260 Analytical-Scale LC Purification System or the 1220 Infinity II LC System?

Choose this model when the workflow is size-exclusion with multidetector detection and bio-inert solvent tolerance (2 M NaCl, 8 M urea, 0.5 M NaOH, 0.5 M HCl) plus 6144-sample capacity. Siblings target analytical-scale purification or routine 1220 LC, not SEC multidetection.

What adjacent system parts and software must be compatible with this SEC configuration?

The bio-LC reference configuration uses a Bio Flexible Pump (G7131A), Bio Multisampler (G7137A) with Sample Thermostat option #101, Multicolumn Thermostat (G7116B) with biocompatible heat exchanger (G7116-60071), and a VWD (G7114B) with biocompatible micro flow cell (G1314-60189), controlled by OpenLab CDS 2.6 or later.

What maintenance schedule and consumables are required, and what is not included in base delivery?

No maintenance schedule is stated in the verified facts. Consumables to plan for include 0.22 µm filters and the 1.8 µm, 2.1 mm × 50 mm SEC column; the brochure prints no ordering codes, so column, filter and flow-cell part numbers must be confirmed separately.

Dimensional Drawings & Technical Documentation

Technical documentation