Agilent Technologies 280FS AA
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies 280FS AA

Agilent Technologies 280FS AA — Atomic spectroscopy.

The Agilent 280FS AA is a Fast Sequential flame atomic absorption spectrometer with transverse Zeeman background correction and an 8-position lamp turret. It measures up to 10 elements per sample in about 2 minutes, with 1% RSD precision and 10 mL sample consumption. It is used for multi-element trace metal analysis in flame AA workflows.

Agilent Technologies Flame Atomic Absorption Instruments Series — Model Comparison & Selection

Model SensitivityPrecision, mmAnalysis time 8 elements, minutesDilution error, %Sample consumption, mLSensitivity increase, %
280FS AA Current —195-11040
240FS AA —195-11040
55B AA 0.90.5————

Full specifications

Core Performance & Functional Specifications
Analysis Time (8 Elements) 95 minutes
Dilution Error -1 %
Precision 1 %RSD
Sample Consumption 10 mL
Sensitivity Increase 40 %
Lamps mfr four four
Background correction mfr Transverse Zeeman Zeeman
Dilution factor mfr 1
Number of determinations mfr 53
Reproducibility mfr 1
Elements measured per sample mfr 10 elements
Analysis time per sample mfr 2 minutes
Lamp positions mfr 8 positions
Default operating mode mfr Fast Sequential Sequential
Lamp count mfr 4 lamps
lamp capacity (240 FS) mfr four lamps lamps
lamp capacity (240Z) mfr four lamps lamps
lamp capacity (280FS) mfr eight lamps lamps
lamp capacity (280Z) mfr eight lamps lamps
elements per sample in Fast Sequential mode mfr 10 minutes
gas and time reduction (PROMT + FS) mfr 60
background correction accuracy improvement mfr 11 improvement
PSD120 autosampler capacity mfr 130 solutions
UltrAA lamp lifetime mfr 8000 hours
SIPS over-range dilution factor mfr 200 x
Standards, Safety & General Data
Standard concentration mfr 5 mg/L

Description

Construction and series positioning

Behavior under load and in different modes

Installation, connection and control

Integration & Operating Notes

Process Limits
Fast Sequential mode fixes the element sequence per sample

Because the 280FS AA measures elements sequentially rather than simultaneously, the order and number of elements in a method determine cycle time; the verified 10-element, ~2-minute cycle and 95-minute 8-element run are consequences of that sequencing, so method design must account for lamp turret position and element order.

Technical overview 5991 6666EN, Fast Sequential mode
Control & I/O
One computer controls the spectrometer and accessories

The Agilent AA range documentation states that flame and furnace instruments, including Duo combinations, are controlled by one computer; the 280FS AA therefore integrates into a single-PC control architecture, and accessory systems such as SIPS are managed through the same host rather than standalone controllers.

Range document 5990 6495EN
Maintenance
SIPS pumps are accessory hardware requiring separate service

SIPS 10 and SIPS 20 are sample introduction pump systems supplied as accessories for SpectrAA FAAS instruments, not part of the 280FS AA base delivery; their peristaltic pump tubing is a consumable that must be scheduled and replaced independently of the spectrometer's own maintenance.

SIPS accessory document 5991 6613EN

Selection & Integration Q&A

When should I choose the 280FS AA rather than the 240FS AA or the 55B AA?

Pick the 280FS AA for multi-element flame work needing transverse Zeeman background correction and an 8-position lamp turret with Fast Sequential operation. The 240FS AA is the other FS flame model; the 55B AA is a single-element flame instrument (0.9 Abs sensitivity) without the FS multi-element workflow.

What sample introduction and vapor generation accessories are required, and are they included?

SIPS 10 (single pump) or SIPS 20 (dual pump) sample introduction pump systems and the VGA 77 vapor generation accessory are separate items for SpectrAA FAAS instruments; they are not part of the 280FS AA base delivery and must be ordered and integrated separately.

What control architecture and duty cycle should I plan for in a multi-element method?

The 280FS AA runs under a single controlling computer. In Fast Sequential mode, 10 elements take about 2 minutes per sample, while an 8-element run is quoted at 95 minutes; plan method sequences and lamp turret positions around this sequential timing rather than assuming simultaneous detection.

What maintenance and consumables fall outside the base instrument delivery?

SIPS pump tubing and VGA 77 vapor generation components are accessory consumables serviced separately from the spectrometer. The base 280FS AA delivery does not include SIPS 10/20 pumps or VGA 77; schedule their tubing replacement independently of the instrument's own lamp and burner maintenance.