Agilent Technologies 6495D mass spectrometer
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies 6495D mass spectrometer

Agilent Technologies 6495D mass spectrometer — Liquid chromatography mass spectrometry lc ms with Pumping speed 4.8×10⁻⁵ m³/h.

The 6495D is a triple quadrupole LC/MS with Agilent Jet Stream electrospray ionization, configured for PFAS analysis in complex matrices. It sustains over 13,700 continuous injections with 7.5% peak-area RSD, using iFunnel modes tuned per analyte. It serves as the detection and quantification stage in LC/MS/MS workflows requiring long-run robustness.

Pumping speed
4.8×10⁻⁵ m³/h

Full specifications

Core Performance & Functional Specifications
Pumping speed 0.8 mL/min
Centrifugation Speed 4000 rpm
Column temperature 45 °C
Extraction Solvent Volume 10 mL
Nebulizer Gas Pressure 24 psi
Peak Area Rsd 7.5 %
Sample volume 2 μL
Software version mfr 2.2
Minimum required software version mfr 1.0
Number of continuous injections mfr 13700 injections
Gradient %B at 1.5 min mfr 90
Stop time mfr 3.0 min
Vortex mixing time mfr 10 minutes
PFHxS precursor m/z mfr 398.9 m/z
PFHxS product m/z mfr 99.0 m/z
PFHxS retention time mfr 1.44 min
PFOA precursor m/z mfr 413.0 m/z
PFOA product m/z mfr 369.0 m/z
PFOA retention time mfr 1.39 min
PFNA precursor m/z mfr 463.0 m/z
PFNA product m/z mfr 419.0 m/z
PFNA retention time mfr 1.52 min
PFOS precursor m/z mfr 498.9 m/z
PFOS product m/z mfr 80.0 m/z
PFOS retention time mfr 1.67 min
iFunnel mode PFHxS/PFOS mfr Large Mol. Mol.
iFunnel mode PFOA/PFNA mfr Fragile Fragile
Vortex mixing duration mfr 10 minutes
Retention time PFHxS mfr 1.44 min
Retention time PFOA mfr 1.39 min
Retention time PFNA mfr 1.52 min
Retention time PFOS mfr 1.67 min
Precursor m/z PFHxS mfr 398.9 m/z
Product m/z PFHxS mfr 99.0 m/z
Precursor m/z PFOA mfr 413.0 m/z
Product m/z PFOA mfr 369.0 m/z
Precursor m/z PFNA mfr 463.0 m/z
Product m/z PFNA mfr 419.0 m/z
Precursor m/z PFOS mfr 498.9 m/z
Product m/z PFOS mfr 80.0 m/z
Operating system name, version mfr 10 bit
G5654A mfr 1260 Pump
G7104A mfr 1290 Pump
G7104C mfr 1260 Pump
G7110B mfr 1260 Pump
G7111A mfr 1260 VL
G7111B mfr 1260 Pump
G7112B mfr 1260 Pump
G7120A mfr 1290 Pump
G7131A mfr 1290 Pump
G7131C mfr 1260 Pump
G7132A mfr 1290 Pump
G7114A mfr 1260 Detector
G7114B mfr 1290 Detector
G7115A mfr 1260 WR
G7117A mfr 1290 FS
G7117B mfr 1290 Detector
G7117C mfr 1260 HS
G7121A mfr 1260 Detector
G7121B mfr 1260 Spectra
G7162A mfr 1260 Detector
G7162B mfr 1290 Detector
G7165A mfr 1260 Detector
G6160B mfr Agilent InfinityLab Pro iQ Mass Detector Detecto
G6170A mfr Agilent InfinityLab Pro iQ Plus Mass Detector De
G7123B mfr 1290 Detector
G6495D mfr 6495 LC/MS
G6475A mfr 6475 LC/MS
G6465B mfr Ultivo Triple Quadrupole LC/MS LC/MS
Agilent 2D-LC System Driver mfr 2 Driver.
Agilent 1200 Infinity Series High Dynamic Range DAD Solution mfr 7117 applications
Valve-thermostat Cluster maximum columns mfr 32 columns
Stop Time mfr 3.0 min
Injection volume (performance monitoring) mfr 2 μL
Injection volume (matrix) mfr 10 μL
Performance monitoring sample total volume mfr 1.38 mL
Matrix injection total volume mfr 137 mL
Grand total matrix volume mfr 138.38 mL
Equivalent 2 μL sample injections mfr 69190
Matrix injections count mfr 13700
Performance monitoring injections count mfr 690
Electrical, Power & Drive Specifications
Mobile phase A mfr 2 acetate
Collision energy PFOS mfr 52 V
Collision energy PFHxS mfr 43 V
Collision energy PFOA mfr 7 V
Collision energy PFNA mfr 8 V
Mobile Phase A mfr 2 acetate
Mobile Phase B mfr ACN ACN
Standards, Safety & General Data
Sample preparation salt part number mfr 5982 CH

Description

Construction and series positioning

The 6495D is the high-sensitivity triple quadrupole LC/MS in Agilent's 6400 series, distinguished from the 6475 by its iFunnel ion guide and AJS-ESI source. The iFunnel operates in two modes: 'Large Mol.' for PFHxS/PFOS and 'Fragile' for PFOA/PFNA, allowing per-analyte tuning. This modification targets PFAS workflows in complex matrices such as salmon, where long unattended sequences are required.

Behavior under load

The system was validated over 13,700 continuous injections with a peak-area RSD of 7.5%, demonstrating stability across extended runs. PFAS analytes elute between 1.39 and 1.67 min under the tested gradient (90% B at 1.5 min, stop time 3.0 min), with precursor/product transitions such as PFHxS 398.9→99.0 and PFOA 413.0→369.0. Collision energy for PFOS is 52 V. These conditions reflect the instrument's performance in a defined method, not universal defaults.

Installation and control

Operation requires InfinityLab Assist Control Software version 2.2 (minimum 1.0). The software release note covers compatibility with LC modules, detectors, valve drives, and LC/MS instruments. Nebulizer pressure is set to 24 psi in the PFAS method. Sample preparation includes vortex mixing for 10 minutes and use of a salt part number 5982.

Integration & Operating Notes

Control & I/O
Software version 2.2 required for full 6495D control

The 6495D must be controlled with InfinityLab Assist Control Software 2.2; version 1.0 is the minimum but may not support all features. Verify the installed software before commissioning, as older versions can limit instrument control or data integrity.

Assist Control Software Release Note 2.2
Process Limits
iFunnel mode must match analyte fragility

Use 'Large Mol.' mode for PFHxS and PFOS, and 'Fragile' mode for PFOA and PFNA. Selecting the wrong mode can reduce sensitivity or cause fragmentation, so method parameters must be set per analyte group.

Technical Overview PFAS Robustness 5994-8641EN
Maintenance
Plan for source cleaning after high-injection-count runs

The robustness test exceeded 13,700 injections; at such duty cycles, schedule preventive maintenance of the AJS-ESI source and iFunnel to preserve 7.5% peak-area RSD. Consult the manual for cleaning intervals based on matrix load.

Technical Overview PFAS Robustness 5994-8641EN

Selection & Integration Q&A

When should I choose the 6495D over the 6475 LC/MS/MS?

Choose the 6495D for PFAS or trace analysis in complex matrices requiring iFunnel modes and long unattended runs (validated >13,700 injections). The 6475 lacks the iFunnel and is suited for routine, less demanding workflows.

What LC and software components are required to operate the 6495D?

The 6495D requires an LC module compatible with InfinityLab Assist Control Software 2.2 (minimum 1.0). The release note lists supported LC modules, detectors, and valve drives; ensure the LC stack is on the compatibility list.

What maintenance and consumables are needed beyond base delivery?

Base delivery excludes LC columns, PFAS sample prep salts (e.g., part 5982), and source cleaning supplies. Plan for regular AJS-ESI source maintenance and iFunnel cleaning; intervals depend on matrix load and injection count.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
InfinityLab Assist Control Software Release Note
Manual ·194,9 КБ ·14 pp.
View PDF
PDF
Long Term Robustness of PFAS Analysis in Complex Matrices
Brochure ·1,0 МБ ·7 pp.
View PDF