No photo available yet

Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies Custom Gene Expression Microarray

Agilent Technologies Custom Gene Expression Microarray — Gene expression microarray platform.

Custom gene expression microarrays are a consumable, not an instrument: a user-defined probe set on Agilent's 60-mer oligo platform, processed with the Low Input Quick Amp labeling protocol. This modification is defined by its low-input window — 10–200 ng total RNA or 5 ng polyA RNA — and by the Spike Mix/Spike A/B dilution scheme that must be matched to the starting input. It is used to interrogate user-specified transcripts in one- or two-color hybridizations.

Agilent Technologies Custom Microarrays Series — Model Comparison & Selection

Model Total rna input, ngTotal rna input highest listed, ngTotal rna input lowest listed, ngCdna synthesis incubation, °CCdna synthesis incubation time, hoursCrna elution volume, microliter
Custom Gene Expression Microarray Current 10...2002001040230
Take gene expression to the next level, Custom Exon Microarrays 251002540230

Full specifications

Core Performance & Functional Specifications
10× Blocking Agent Reconstitution Volume 500 µL
Cdna Synthesis Incubation Time 2 hours
Crna Elution Volume 30 µL
Crna Purification Centrifugation 13000 rpm
Crna Transcription Incubation Time 2 hours
Enzyme Inactivation Time 15 minutes
Fragmentation Incubation Time 30 minutes
Hybridization Duration 17 hours
Hybridization Mix Total Volume 250 µL
Hybridization Rotator Speed 10 rpm
Hybridization Time 17 hours
Hybridization Volume 490 µL
Maximum Total Rna Sample Volume 2.3 µL
Minimum Pipette Dispensing Volume 2 µL
Pipetting volume 2 µL
Poly A Mrna Input 5 ng
Polya Rna Input, Lowest Listed 5 ng
Primer/template Denaturation Time 10 minutes
Recommended Crna Yield 5 µg
Spike Mix Heat Incubation Time 5 minutes
Spike Mix Volume Per 100 Ng Total Rna 1 µL
Spike Mix Volume Per Labeling Reaction 2 µL
Starting Total Rna Amount 25 ng
Step 1 Time Required 0.5 hours
Total Rna Input 10...200 ng
Total Rna Input, Highest Listed 200 ng
Total Rna Input, Lowest Listed 10 ng
Total Volume 3
Triton X-102 Final Concentration In Wash Buffers 0.005 %
Spike A Mix labeling dye mfr 3
Feature Extraction Software version for SpikeIns LogRatio Statistics mfr 10.7.3 later
Starting total RNA input variants mfr four different starting sample inputs inputs
Amplification factor total RNA to cRNA mfr 100 fold
Minimum total RNA input for high quality data mfr 10 ng
Total RNA plus spike-in volume limit mfr 3.5 μL
Recommended specific activity mfr 15 cRNA
Cyanine 3-labeled cRNA in fragmentation mix mfr 600 ng
Microarray slide format mfr 1 slide
Minimum total RNA for high quality data mfr 10 ng
Maximum volume of total RNA plus diluted spike-in mfr 3.5 μL
First spike dilution storage mfr 2 months
Step 1 time required (Prepare Spike A Mix and Spike B) mfr 0.5 hours
Step 2 time required (Prepare labeling reaction) mfr 5.5 hours
Step 3 time required (Purify labeled/amplified RNA) mfr 0.5 hours
Cyanine 3-labeled cRNA per hybridization mfr 300 ng
Agilent Microarray Scanner mfr 4900 BA
Hybridization gasket slides 1 microarray/slide, 5 slides/box mfr 2534
Hybridization gasket slides 2 microarrays/slide, 5 slides/box mfr 2534
Hybridization gasket slides 4 microarrays/slide, 5 slides/box mfr 2534
Hybridization gasket slides 8 microarrays/slide, 5 slides/box mfr 2534
G4852B mfr 3 Kit
G4858A-074809 mfr 3 Microarray
G4852A mfr 3 Kit
G4858A-028005 mfr 3 Microarray
G4846A mfr 4 Kit
G2519F-026655 mfr 4 Microarray
RNA 6000 Nano Assay Kit (RNA Series II Kit) mfr 5067
Quick Amp Labeling Kit, One-Color mfr 5190
Stabilization and Drying Solution* mfr 5185
Ozone-Barrier Slide Cover* mfr 2505
Absolutely RNA Nanoprep Kit mfr 400753
slide box mfr 07201629
acetonitrile mfr 271004 L
sulfolane mfr 22209
thermal cycler mfr 96 tubes
G4851C mfr 3 Kit
G4858A-072363 mfr 3 Microarray
G4851B mfr 3 Kit
G4858A-039494 mfr 3 Microarray
G4851A mfr 3 Kit
G4858A-028004 mfr 3 Microarray
G4845A mfr 4 Kit
G2519F-026652 mfr 4 Microarray
Hybridization oven rotator for Agilent Microarray Hybridization Chambers mfr 2530
nuclease-free 1.5 mL microfuge tube mfr 12400 equivalent
magnetic stir bar (×2) mfr 401435 equivalent
magnetic stir plate (×2) mfr 6795 equivalent
circulating water baths or heat blocks set to 37°C, 40°C, 60°C, 65°C, 70°C, and 80°C mfr 6795 equivalent
microcentrifuge mfr 5417 equivalent
sterile storage bottle mfr 455 equivalent
spectrophotometer mfr -1000 equivalent
micropipettor mfr -10 equivalent
slide-staining dish, with slide rack (×3) mfr 121 equivalent
RNA 6000 Nano LabChip Kit mfr 5067
RNA 6000 Pico LabChip Kit mfr 5067
Universal Human Reference RNA mfr 740000
Universal Mouse Reference RNA mfr 740100
Universal Rat Reference RNA mfr 740200
Low Input Quick Amp Labeling Kit, One-Color mfr 5190
RNA Spike-In Kit, One-Color mfr 5188
Gene Expression Hybridization Kit mfr 5188
Gene Expression Wash Buffer Kit mfr 5188
DNase/RNase-free distilled water mfr 10977
RNeasy Mini Kit mfr 74104
ethanol (95% to 100% molecular biology grade) mfr 7023 ML
amplification factor mfr 100 fold
first dilution storage duration mfr 2 months
ozone level threshold mfr 50 ppb
scan resolution mfr 5 μm
Feature Extraction minimum version for eArray download mfr 10.7
Quick Amp Labeling Kit, Two-Color mfr 5190
Low Input Quick Amp Labeling Kit, Two-Color mfr 5190
RNA Spike-In Kit, Two-Color mfr 5188
amplification fold mfr 100 fold
Triton X-102 addition volume mfr 2 mL
acetonitrile wash time mfr 10 seconds
stabilization and drying wash time mfr 30 seconds
G4832A mfr 3 Kit
G4857A-028679 mfr 3 Microarray
G4848A mfr 3 Kit
G4856A-028680 mfr 3 Microarray
vacuum concentrator mfr 120 equivalent
Low Input Quick Amp WT Labeling Kit, Two-Color mfr 5190
Spectrophotometer mfr -1000 equivalent
Affinity Script RNase Block Mix (violet cap) mfr 1.2
minimum labeled cRNA per microarray mfr 1.65 μg
ozone robustness level mfr 5 ppb
thermocycler program 1 time mfr 10 minutes
thermocycler program 2 time mfr 2 hours
thermocycler program 2 second time mfr 15 minutes
thermocycler hold time mfr 5 minutes
cRNA size range lower bound mfr 200 nucleotides
Electrical, Power & Drive Specifications
Hybridization Chamber, stainless mfr 2534 A
Interfaces, Connections & Control
Spike Mix first serial dilution mfr 1
Spike Mix second serial dilution mfr 1
Spike Mix third serial dilution mfr 1
Spike A Mix serial dilution (first) mfr 1
Spike A Mix serial dilution (second) mfr 1
Spike A Mix serial dilution (third) mfr 1
Spike A Mix serial dilution (fourth) mfr 1
Spike mix serial dilution first mfr 1
Spike mix serial dilution second mfr 1
Spike mix serial dilution third mfr 1
Spike mix serial dilution fourth mfr 1
Serial dilution first mfr 1
Serial dilution second mfr 1
Serial dilution third mfr 1
Serial dilution fourth mfr 1
Operating Conditions, Environment & Protection
Cdna Synthesis Incubation 40 °C
Crna Transcription Incubation Temperature 40 °C
Enzyme Inactivation Temperature 70 °C
First Strand Buffer Prewarm Temperature 80 °C
Fragmentation Incubation 60 °C
Hybridization Temperature 65 °C
Spike Mix Heat Incubation Temperature 37 °C
Spike Mix Heating Temperature 37 °C
Storage Temperature Of 10× Blocking Agent -20 °C
Storage Temperature Of Total Rna >100 Ng/µl -80 °C
T7 Primer Denaturation Temperature 65 °C
Wash Buffer 2 Prewarm Temperature 37 °C
AffinityScript inactivation incubation mfr 70 °C
G4122F mfr 4 K
G2519F-014868 mfr 4 K
G2519F-021169 mfr 4 K
G2519F-021623 mfr 4 K
G2519F-023647 mfr 4 K
G2519F-022520 mfr 4 K
G2519F-021193 mfr 4 K
G2519F-020186 mfr 4 K
G2519F-026441 mfr 4 K
G2519F-022523 mfr 4 K
G2519F-021791 mfr 4 K
G2519F-021322 mfr 4 K
G2519F-015060 mfr 4 K
G2519F-022524 mfr 4 K
G2519F-020449 mfr 4 K
G2519F-026440 mfr 4 K
G2519F-026806 mfr 4 K
G2519F-020908 mfr 4 K
G2519F-015241 mfr 4 K
G2519F-020938 mfr 4 K
G4813A-019921 mfr 8 K
G2519F-021113 mfr 4 K
G2519F-022297 mfr 4 K
G4813A-016322 mfr 8 K
G2519F-026437 mfr 4 K

Description

What this modification is

Input window and spike-in behavior

Handling and workflow

Integration & Operating Notes

Process Limits
Match the spike dilution scheme to the actual RNA input

The spike dilution series is defined per input level (25, 50 and 100 ng schemes in the exon two-color protocol), so loading a spike mix prepared for one input onto a different input invalidates the SpikeIns LogRatio statistics. Confirm the starting total RNA amount before preparing Spike A/B.

G4140 90052 Exon Two Color 2.0, Step 1 Prepare Spike A Mix and Spike B
Process Limits
Stay inside the 10–200 ng total RNA / 5 ng polyA window

Below the lowest listed input the Low Input Quick Amp labeling chemistry is outside its validated range, and above the highest listed input the protocol's spike and amplification balance no longer applies. Inputs outside the window require a different protocol, not a scaled reagent volume.

Factory Specification Sheet; G4140 90040 GeneExpression OneColor 6.9
Control & I/O
Feature Extraction 10.7.3 or later for SpikeIns statistics

SpikeIns LogRatio statistics are only produced by Feature Extraction Software version 10.7.3 or later. An older extraction build will run but will not emit these QC metrics, so the spike-in performance check silently disappears from the report.

G4140 90040 GeneExpression OneColor 6.9, Step 2 Extract data
Process Limits
Heat Spike Mix at 37 °C for 5 minutes before dispensing

The spike mix heat incubation is a fixed 37 °C / 5 minute step; skipping or extending it changes the spike transcript state before the 2 µL addition to each labeling reaction. Treat it as a timed step in the workflow, not an optional warm-up.

G4140 90050 GeneExpression TwoColor 6.9.1, Step 1 Prepare Spike A Mix and Spike B
Maintenance
Pipettes must deliver 2 µL reliably before starting

The minimum pipette dispensing volume is 2 µL, and the spike mix is added at exactly 2 µL per labeling reaction. Calibrate and verify pipettes at that volume before the run; a pipette that is only checked at 10 µL or above will introduce spike-mix error that propagates into the LogRatio statistics.

Factory Specification Sheet; G4140 90050 GeneExpression TwoColor 6.9.1
Process Limits
One-color and two-color workflows use different spike mixes

The one-color protocol prepares a single Spike Mix, while the two-color protocol prepares Spike A (dye 3) and Spike B (dye 5) as separate mixes. Do not carry a one-color spike mix into a two-color experiment; the dye assignment and dilution series differ.

G4140 90040 GeneExpression OneColor 6.9; G4140 90050 GeneExpression TwoColor 6.9.1

Selection & Integration Q&A

When should I choose this custom gene expression array instead of the custom exon array or the yeast gene expression array?

Pick this array when the targets are user-defined transcripts and the input is in the 10–200 ng total RNA or 5 ng polyA window under Low Input Quick Amp labeling. Choose the custom exon array when exon-level resolution is required, and the yeast array when the organism is S. cerevisiae and a pre-designed content set is sufficient.

What does the adjacent workflow need to support — labeling reagents, spike mixes and extraction software — for this array to produce valid data?

The workflow must run the Low Input Quick Amp labeling protocol with a spike mix matched to the input (Spike Mix for one-color; Spike A dye 3 and Spike B dye 5 for two-color), dispensed at 2 µL per reaction with pipettes verified at 2 µL. Data extraction must use Feature Extraction Software 10.7.3 or later to obtain SpikeIns LogRatio statistics.

What input and handling limits constrain the experiment before hybridization?

Total RNA input must stay between 10 and 200 ng (polyA RNA down to 5 ng); the spike dilution scheme is chosen for the actual input (25, 50 or 100 ng schemes are defined in the exon two-color protocol). Spike Mix is heat-incubated at 37 °C for 5 minutes, Step 1 takes 0.5 hours, and an 80 °C water bath equilibration is specified.

What must be procured or scheduled beyond the array itself, and what is not in the base delivery?

The array is a consumable: labeling reagents, spike mixes and the Feature Extraction Software are separate items, and no cables or accessories apply. Schedule 0.5 hours for Step 1 spike preparation, verify pipettes at the 2 µL minimum dispensing volume, and confirm the extraction software is at 10.7.3 or later before the run.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
One-Color Microarray-Based Gene Expression Analysis (Low Input Quick Amp Labeling) Protocol
Manual ·5,1 МБ ·100 pp.
View PDF
PDF
Two-Color Microarray-Based Gene Expression Analysis (Low Input Quick Amp Labeling) Protocol
Manual ·1,7 МБ ·98 pp.
View PDF
PDF
Agilent Two-Color Microarray-Based Gene Expression Analysis (Low Input Quick Amp Labeling) Protocol
Manual ·1,5 МБ ·82 pp.
View PDF