No photo available yet
Agilent Technologies Custom Gene Expression Microarray
Agilent Technologies Custom Gene Expression Microarray — Gene expression microarray platform.
Custom gene expression microarrays are a consumable, not an instrument: a user-defined probe set on Agilent's 60-mer oligo platform, processed with the Low Input Quick Amp labeling protocol. This modification is defined by its low-input window — 10–200 ng total RNA or 5 ng polyA RNA — and by the Spike Mix/Spike A/B dilution scheme that must be matched to the starting input. It is used to interrogate user-specified transcripts in one- or two-color hybridizations.
Agilent Technologies Custom Microarrays Series — Model Comparison & Selection
| Model | Total rna input, ng | Total rna input highest listed, ng | Total rna input lowest listed, ng | Cdna synthesis incubation, °C | Cdna synthesis incubation time, hours | Crna elution volume, microliter |
|---|---|---|---|---|---|---|
| Custom Gene Expression Microarray Current | 10...200 | 200 | 10 | 40 | 2 | 30 |
| Take gene expression to the next level, Custom Exon Microarrays | 25 | 100 | 25 | 40 | 2 | 30 |
Full specifications
| 10× Blocking Agent Reconstitution Volume | 500 µL |
| Cdna Synthesis Incubation Time | 2 hours |
| Crna Elution Volume | 30 µL |
| Crna Purification Centrifugation | 13000 rpm |
| Crna Transcription Incubation Time | 2 hours |
| Enzyme Inactivation Time | 15 minutes |
| Fragmentation Incubation Time | 30 minutes |
| Hybridization Duration | 17 hours |
| Hybridization Mix Total Volume | 250 µL |
| Hybridization Rotator Speed | 10 rpm |
| Hybridization Time | 17 hours |
| Hybridization Volume | 490 µL |
| Maximum Total Rna Sample Volume | 2.3 µL |
| Minimum Pipette Dispensing Volume | 2 µL |
| Pipetting volume | 2 µL |
| Poly A Mrna Input | 5 ng |
| Polya Rna Input, Lowest Listed | 5 ng |
| Primer/template Denaturation Time | 10 minutes |
| Recommended Crna Yield | 5 µg |
| Spike Mix Heat Incubation Time | 5 minutes |
| Spike Mix Volume Per 100 Ng Total Rna | 1 µL |
| Spike Mix Volume Per Labeling Reaction | 2 µL |
| Starting Total Rna Amount | 25 ng |
| Step 1 Time Required | 0.5 hours |
| Total Rna Input | 10...200 ng |
| Total Rna Input, Highest Listed | 200 ng |
| Total Rna Input, Lowest Listed | 10 ng |
| Total Volume | 3 |
| Triton X-102 Final Concentration In Wash Buffers | 0.005 % |
| Spike A Mix labeling dye mfr | 3 |
| Feature Extraction Software version for SpikeIns LogRatio Statistics mfr | 10.7.3 later |
| Starting total RNA input variants mfr | four different starting sample inputs inputs |
| Amplification factor total RNA to cRNA mfr | 100 fold |
| Minimum total RNA input for high quality data mfr | 10 ng |
| Total RNA plus spike-in volume limit mfr | 3.5 μL |
| Recommended specific activity mfr | 15 cRNA |
| Cyanine 3-labeled cRNA in fragmentation mix mfr | 600 ng |
| Microarray slide format mfr | 1 slide |
| Minimum total RNA for high quality data mfr | 10 ng |
| Maximum volume of total RNA plus diluted spike-in mfr | 3.5 μL |
| First spike dilution storage mfr | 2 months |
| Step 1 time required (Prepare Spike A Mix and Spike B) mfr | 0.5 hours |
| Step 2 time required (Prepare labeling reaction) mfr | 5.5 hours |
| Step 3 time required (Purify labeled/amplified RNA) mfr | 0.5 hours |
| Cyanine 3-labeled cRNA per hybridization mfr | 300 ng |
| Agilent Microarray Scanner mfr | 4900 BA |
| Hybridization gasket slides 1 microarray/slide, 5 slides/box mfr | 2534 |
| Hybridization gasket slides 2 microarrays/slide, 5 slides/box mfr | 2534 |
| Hybridization gasket slides 4 microarrays/slide, 5 slides/box mfr | 2534 |
| Hybridization gasket slides 8 microarrays/slide, 5 slides/box mfr | 2534 |
| G4852B mfr | 3 Kit |
| G4858A-074809 mfr | 3 Microarray |
| G4852A mfr | 3 Kit |
| G4858A-028005 mfr | 3 Microarray |
| G4846A mfr | 4 Kit |
| G2519F-026655 mfr | 4 Microarray |
| RNA 6000 Nano Assay Kit (RNA Series II Kit) mfr | 5067 |
| Quick Amp Labeling Kit, One-Color mfr | 5190 |
| Stabilization and Drying Solution* mfr | 5185 |
| Ozone-Barrier Slide Cover* mfr | 2505 |
| Absolutely RNA Nanoprep Kit mfr | 400753 |
| slide box mfr | 07201629 |
| acetonitrile mfr | 271004 L |
| sulfolane mfr | 22209 |
| thermal cycler mfr | 96 tubes |
| G4851C mfr | 3 Kit |
| G4858A-072363 mfr | 3 Microarray |
| G4851B mfr | 3 Kit |
| G4858A-039494 mfr | 3 Microarray |
| G4851A mfr | 3 Kit |
| G4858A-028004 mfr | 3 Microarray |
| G4845A mfr | 4 Kit |
| G2519F-026652 mfr | 4 Microarray |
| Hybridization oven rotator for Agilent Microarray Hybridization Chambers mfr | 2530 |
| nuclease-free 1.5 mL microfuge tube mfr | 12400 equivalent |
| magnetic stir bar (×2) mfr | 401435 equivalent |
| magnetic stir plate (×2) mfr | 6795 equivalent |
| circulating water baths or heat blocks set to 37°C, 40°C, 60°C, 65°C, 70°C, and 80°C mfr | 6795 equivalent |
| microcentrifuge mfr | 5417 equivalent |
| sterile storage bottle mfr | 455 equivalent |
| spectrophotometer mfr | -1000 equivalent |
| micropipettor mfr | -10 equivalent |
| slide-staining dish, with slide rack (×3) mfr | 121 equivalent |
| RNA 6000 Nano LabChip Kit mfr | 5067 |
| RNA 6000 Pico LabChip Kit mfr | 5067 |
| Universal Human Reference RNA mfr | 740000 |
| Universal Mouse Reference RNA mfr | 740100 |
| Universal Rat Reference RNA mfr | 740200 |
| Low Input Quick Amp Labeling Kit, One-Color mfr | 5190 |
| RNA Spike-In Kit, One-Color mfr | 5188 |
| Gene Expression Hybridization Kit mfr | 5188 |
| Gene Expression Wash Buffer Kit mfr | 5188 |
| DNase/RNase-free distilled water mfr | 10977 |
| RNeasy Mini Kit mfr | 74104 |
| ethanol (95% to 100% molecular biology grade) mfr | 7023 ML |
| amplification factor mfr | 100 fold |
| first dilution storage duration mfr | 2 months |
| ozone level threshold mfr | 50 ppb |
| scan resolution mfr | 5 μm |
| Feature Extraction minimum version for eArray download mfr | 10.7 |
| Quick Amp Labeling Kit, Two-Color mfr | 5190 |
| Low Input Quick Amp Labeling Kit, Two-Color mfr | 5190 |
| RNA Spike-In Kit, Two-Color mfr | 5188 |
| amplification fold mfr | 100 fold |
| Triton X-102 addition volume mfr | 2 mL |
| acetonitrile wash time mfr | 10 seconds |
| stabilization and drying wash time mfr | 30 seconds |
| G4832A mfr | 3 Kit |
| G4857A-028679 mfr | 3 Microarray |
| G4848A mfr | 3 Kit |
| G4856A-028680 mfr | 3 Microarray |
| vacuum concentrator mfr | 120 equivalent |
| Low Input Quick Amp WT Labeling Kit, Two-Color mfr | 5190 |
| Spectrophotometer mfr | -1000 equivalent |
| Affinity Script RNase Block Mix (violet cap) mfr | 1.2 |
| minimum labeled cRNA per microarray mfr | 1.65 μg |
| ozone robustness level mfr | 5 ppb |
| thermocycler program 1 time mfr | 10 minutes |
| thermocycler program 2 time mfr | 2 hours |
| thermocycler program 2 second time mfr | 15 minutes |
| thermocycler hold time mfr | 5 minutes |
| cRNA size range lower bound mfr | 200 nucleotides |
| Hybridization Chamber, stainless mfr | 2534 A |
| Spike Mix first serial dilution mfr | 1 |
| Spike Mix second serial dilution mfr | 1 |
| Spike Mix third serial dilution mfr | 1 |
| Spike A Mix serial dilution (first) mfr | 1 |
| Spike A Mix serial dilution (second) mfr | 1 |
| Spike A Mix serial dilution (third) mfr | 1 |
| Spike A Mix serial dilution (fourth) mfr | 1 |
| Spike mix serial dilution first mfr | 1 |
| Spike mix serial dilution second mfr | 1 |
| Spike mix serial dilution third mfr | 1 |
| Spike mix serial dilution fourth mfr | 1 |
| Serial dilution first mfr | 1 |
| Serial dilution second mfr | 1 |
| Serial dilution third mfr | 1 |
| Serial dilution fourth mfr | 1 |
| Cdna Synthesis Incubation | 40 °C |
| Crna Transcription Incubation Temperature | 40 °C |
| Enzyme Inactivation Temperature | 70 °C |
| First Strand Buffer Prewarm Temperature | 80 °C |
| Fragmentation Incubation | 60 °C |
| Hybridization Temperature | 65 °C |
| Spike Mix Heat Incubation Temperature | 37 °C |
| Spike Mix Heating Temperature | 37 °C |
| Storage Temperature Of 10× Blocking Agent | -20 °C |
| Storage Temperature Of Total Rna >100 Ng/µl | -80 °C |
| T7 Primer Denaturation Temperature | 65 °C |
| Wash Buffer 2 Prewarm Temperature | 37 °C |
| AffinityScript inactivation incubation mfr | 70 °C |
| G4122F mfr | 4 K |
| G2519F-014868 mfr | 4 K |
| G2519F-021169 mfr | 4 K |
| G2519F-021623 mfr | 4 K |
| G2519F-023647 mfr | 4 K |
| G2519F-022520 mfr | 4 K |
| G2519F-021193 mfr | 4 K |
| G2519F-020186 mfr | 4 K |
| G2519F-026441 mfr | 4 K |
| G2519F-022523 mfr | 4 K |
| G2519F-021791 mfr | 4 K |
| G2519F-021322 mfr | 4 K |
| G2519F-015060 mfr | 4 K |
| G2519F-022524 mfr | 4 K |
| G2519F-020449 mfr | 4 K |
| G2519F-026440 mfr | 4 K |
| G2519F-026806 mfr | 4 K |
| G2519F-020908 mfr | 4 K |
| G2519F-015241 mfr | 4 K |
| G2519F-020938 mfr | 4 K |
| G4813A-019921 mfr | 8 K |
| G2519F-021113 mfr | 4 K |
| G2519F-022297 mfr | 4 K |
| G4813A-016322 mfr | 8 K |
| G2519F-026437 mfr | 4 K |
Description
What this modification is
- A custom-designed microarray: the probe content is user-defined, so the array itself carries no fixed gene list; the sibling exon arrays and the yeast gene expression arrays are pre-designed content sets, and are the right choice when a standard catalog covers the targets.
- The processing chemistry is the Low Input Quick Amp labeling protocol (one-color v6.9, two-color v6.9.1, exon two-color v2.0), which sets the input window and the spike-in scheme.
Input window and spike-in behavior
- Total RNA input spans 10 ng (lowest listed) to 200 ng (highest listed); polyA RNA input goes down to 5 ng.
- Spike Mix is prepared as a four-step serial dilution series and added at 2 µL per labeling reaction; the Spike Mix is heat-incubated at 37 °C for 5 minutes before use.
- The two-color protocol uses two separate spike mixes: Spike A carries dye 3 and Spike B carries dye 5, each with its own four-step dilution series.
- The exon two-color protocol defines spike dilution schemes for 25, 50 and 100 ng total RNA inputs; the starting total RNA amount is stated as 100 ng in the factory data, and four different starting sample inputs are listed as variants — the dilution scheme must be selected to match the actual input, not assumed.
Handling and workflow
- Minimum pipette dispensing volume is 2 µL, which sets the practical floor for all reagent transfers in the spike and labeling steps.
- Step 1 (spike mix preparation) requires 0.5 hours.
- A water bath equilibration temperature of 80 °C is specified in the procedure.
- Data extraction is performed with Agilent Feature Extraction Software; SpikeIns LogRatio statistics require version 10.7.3 or later.
Integration & Operating Notes
The spike dilution series is defined per input level (25, 50 and 100 ng schemes in the exon two-color protocol), so loading a spike mix prepared for one input onto a different input invalidates the SpikeIns LogRatio statistics. Confirm the starting total RNA amount before preparing Spike A/B.
Below the lowest listed input the Low Input Quick Amp labeling chemistry is outside its validated range, and above the highest listed input the protocol's spike and amplification balance no longer applies. Inputs outside the window require a different protocol, not a scaled reagent volume.
SpikeIns LogRatio statistics are only produced by Feature Extraction Software version 10.7.3 or later. An older extraction build will run but will not emit these QC metrics, so the spike-in performance check silently disappears from the report.
The spike mix heat incubation is a fixed 37 °C / 5 minute step; skipping or extending it changes the spike transcript state before the 2 µL addition to each labeling reaction. Treat it as a timed step in the workflow, not an optional warm-up.
The minimum pipette dispensing volume is 2 µL, and the spike mix is added at exactly 2 µL per labeling reaction. Calibrate and verify pipettes at that volume before the run; a pipette that is only checked at 10 µL or above will introduce spike-mix error that propagates into the LogRatio statistics.
The one-color protocol prepares a single Spike Mix, while the two-color protocol prepares Spike A (dye 3) and Spike B (dye 5) as separate mixes. Do not carry a one-color spike mix into a two-color experiment; the dye assignment and dilution series differ.
Selection & Integration Q&A
Pick this array when the targets are user-defined transcripts and the input is in the 10–200 ng total RNA or 5 ng polyA window under Low Input Quick Amp labeling. Choose the custom exon array when exon-level resolution is required, and the yeast array when the organism is S. cerevisiae and a pre-designed content set is sufficient.
The workflow must run the Low Input Quick Amp labeling protocol with a spike mix matched to the input (Spike Mix for one-color; Spike A dye 3 and Spike B dye 5 for two-color), dispensed at 2 µL per reaction with pipettes verified at 2 µL. Data extraction must use Feature Extraction Software 10.7.3 or later to obtain SpikeIns LogRatio statistics.
Total RNA input must stay between 10 and 200 ng (polyA RNA down to 5 ng); the spike dilution scheme is chosen for the actual input (25, 50 or 100 ng schemes are defined in the exon two-color protocol). Spike Mix is heat-incubated at 37 °C for 5 minutes, Step 1 takes 0.5 hours, and an 80 °C water bath equilibration is specified.
The array is a consumable: labeling reagents, spike mixes and the Feature Extraction Software are separate items, and no cables or accessories apply. Schedule 0.5 hours for Step 1 spike preparation, verify pipettes at the 2 µL minimum dispensing volume, and confirm the extraction software is at 10.7.3 or later before the run.