Agilent Technologies Electrospray ion Source, ESI

Agilent Technologies Electrospray ion Source, ESI — Liquid chromatography mass spectrometry lc ms with Pumping speed 2.4×10⁻⁵ m³/h.

The electrospray-esi-source is an ESI ion source configuration for Agilent LC/MS systems, specified here in positive ion mode with a 5000 V capillary, 14 L/min drying gas at 290 °C, and 12 L/min sheath gas at 400 °C. It operates at 0.4 mL/min pumping speed with a 20 psi nebulizer and 2000 V nozzle, intended to ionize LC eluent for MS detection.

Pumping speed
2.4×10⁻⁵ m³/h

Agilent Technologies LC MS Ion Sources Series — Model Comparison & Selection

Model Pumping speed, m³/hSample volume, milliliterColumn temperature, °CDrying gas temperature, °CSheath gas flow, liter/minuteSheath gas temperature, °C
Electrospray ion Source, ESI Current 2.4×10⁻⁵0.0018029012400
Atmospheric Pressure Chemical Ionization Source, APCI 2.4×10⁻⁵0.00455350——
High sensitivity MS, high sensitivity ion source, Jet Stream ————0.011350

Full specifications

Core Performance & Functional Specifications
Pumping speed 0.4 mL/min
Column temperature 80 °C
Drying Gas Flow 14 L/min
Sample volume 1 µL
Sheath Gas Flow 12 L/min
Stop time mfr 7 minutes
Ion mode mfr Positive ion mode, ESI ESI
Nebulizer mfr 20 psi
Sample concentration mfr 100 μg/mL
Electrical, Power & Drive Specifications
Capillary Voltage 5000 V
Mobile phase A mfr 0.1 water
Mobile phase B mfr 90 acid
Nozzle mfr 2000 V
Operating Conditions, Environment & Protection
Drying Gas Temperature 290 °C
Sheath Gas Temperature 400 °C
Sample thermostat mfr 5 °C

Description

Construction and positioning

Behavior under operating conditions

Installation and control

Integration & Operating Notes

Electrical
Capillary and nozzle voltages are fixed high-voltage setpoints

The source is specified at 5000 V capillary and 2000 V nozzle in positive ion mode. These high voltages require the MS interlock chain to be intact; the verified facts do not include interlock logic, so the engineer must confirm startup and shutdown sequencing against the instrument manual.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose this ESI source rather than one of the sibling LC/MS instruments such as the 6230 TOF or 6475 triple quadrupole?

This item is the ESI ion source itself, not a complete spectrometer. Choose it when you already have an Agilent LC/MS and need the electrospray interface; choose a sibling (6230 TOF, 6475/6495 QQQ, 6530 Q-TOF) when you need the full mass analyzer with its own detection limits and mass range.

What adjacent system parts and conditions must be compatible with this source?

It is specified for 0.4 mL/min LC flow, 20 psi nebulizer, 14 L/min drying gas at 290 °C, 12 L/min sheath gas at 400 °C, 5000 V capillary and 2000 V nozzle in positive ESI. The LC, gas supplies, and MS must support these setpoints; the verified facts do not list fitting sizes or controller interfaces.

What mounting, environment, or duty-cycle limits apply?

The verified facts contain no mounting dimensions, ambient temperature range, or duty-cycle rating for the source. The only environmental setpoints given are the gas temperatures (290 °C drying, 400 °C sheath) and column/sample thermostat values (80 °C, 5 °C); installation limits must be confirmed from the instrument manual.

What maintenance schedule and accessories are included, and what must be ordered separately?

No maintenance interval, error-code list, cable, or consumable is specified in the verified facts. The attached document 5991 2116EN is an application note for intact protein analysis on a 6550 iFunnel Q-TOF with JetStream and a 1290 Infinity LC, not an ordering datasheet, so accessories and service parts must be confirmed separately.