Agilent Technologies Electron capture dissociation for QTOF LCMS of proteins
Agilent Technologies Electron capture dissociation for QTOF LCMS of proteins — Liquid chromatography mass spectrometry lc ms with Pumping speed 0.024 m³/h.
The ExD cell is an electron-capture dissociation fragmentation module for the Agilent 6545XT AdvanceBio LC/Q-TOF, not a standalone instrument. It enables ECD of peptides and intact proteins in the 120–3,200 m/z range for isobaric Leu/Ile and Asp/isoAsp discrimination. It is specified here with the Dual Jet Stream ESI source, 120 µm column and 0.400 mL/min LC flow.
Agilent Technologies Quadrupole Time Of Flight LC MS Series — Model Comparison & Selection
| Model | Pumping speed, m³/h | Mass range | Acquisition rate, Hz | Autosampler temperature, °C | Column temperature, °C | Sample volume, milliliter |
|---|---|---|---|---|---|---|
| Electron capture dissociation for QTOF LCMS of proteins Current | 0.024 | — | 1 | 5 | 60 | 0.01 |
| 6545XT AdvanceBio UHPLC QTOF, biopharmaceutical analysis | 3×10⁻⁵ | 100...10,000 | 1.0 | 4 | 60 | 5×10⁻⁴ |
| 6560 Ion Mobility QTOF LC/MS, Collision Cross Section | 1.6×10⁻⁸ | 100...1,700 | 10 | 4 | 45 | — |
Full specifications
| Pumping speed | 0.400 mL/min |
| Acquisition Rate | 1 spectrum/sec |
| Column temperature | 60 °C |
| Drying Gas Flow | 10 L/min |
| Ion source | Agilent Dual Jet Stream ESI source |
| Sample volume | 10 µL |
| Sheath Gas Flow | 11 L/min |
| MS1 Spectra Range mfr | 100...3,200 m/z |
| Polarity mfr | Positive Positive |
| Nebulizer mfr | 35 psi |
| Acquisition Mode mfr | Extended Dynamic Range Range |
| Isolation Window mfr | Medium Medium |
| MS Spectrum Range mfr | 120...3,200 |
| MS/MS Spectrum Range mfr | 120...3,200 |
| Intensity Threshold (Abs) mfr | 2000 |
| Intensity Threshold (Rel) mfr | 0.01 |
| Acquisition mode mfr | Extended dynamic range range |
| Gradient mfr | 35...36 |
| Mass Error Tolerance mfr | 20 ppm |
| Antibody molecular weight mfr | 150 kDa |
| Capillary Voltage | 4000 V |
| Nozzle Voltage | 2000 V |
| Skimmer mfr | 75 V |
| Mobile Phase A mfr | 0.1 acid |
| Mobile Phase B mfr | 0.1 acid |
| Fragmentor mfr | 175 V |
| Autosampler Temperature | 5 °C |
| Gas Temperature | 325 °C |
| Sample Storage Temperature | 20 °C |
| Sheath Gas Temperature | 275 °C |
Description
Construction and positioning
- The ExD cell is a fragmentation accessory fitted to the 6545XT AdvanceBio LC/Q-TOF; the sibling models listed (6230 TOF, 6475/6495 triple quadrupole, 6530 Q-TOF) are separate mass spectrometers, not ExD configurations.
- The verified configuration pairs the cell with an Agilent Dual Jet Stream ESI source, a 120 µm column and 0.400 mL/min pumping, with MS1 and MS/MS spectra ranges of 100–3,200 m/z and 120–3,200 m/z respectively.
- Ion optics settings in the verified set: capillary 4000 V, nozzle 2000 V, skimmer 75 V, fragmentor 175 V, nebulizer 35 psi.
Behavior and modes
- Acquisition is specified in positive polarity with Extended Dynamic Range acquisition mode and a Medium isolation window.
- Source gases: drying gas 10 L/min at 325 °C; sheath gas 11 L/min at 275 °C.
- LC and autosampler conditions in the verified set: column 60 °C, autosampler 5 °C, sample storage 20 °C, 10 µL injection, gradient 45–90.
- Data-processing thresholds: absolute intensity 2000, relative 0.01, mass error tolerance 20 ppm.
Operation
- The attached application notes run the cell under MassHunter with ExDControl and ExDViewer software on a 1290 Infinity II Bio LC coupled to the 6545XT.
- Documented uses are ECD fragmentation of a synthetic peptide, intact ubiquitin, GLP-1 analogs (semaglutide, liraglutide, tirzepatide) and a tryptic peptide of a monoclonal antibody antigen-binding region.
Integration & Operating Notes
The verified facts list no certificates, no accessories and no maintenance intervals for the ExD cell. ExDControl and ExDViewer are named only in the application notes, so verify licensing and any source consumables against the order before installation; no service schedule can be stated from the available documents.
Selection & Integration Q&A
Choose the ExD cell when the application needs electron-capture dissociation on a 6545XT AdvanceBio LC/Q-TOF, for example isobaric Leu/Ile or Asp/isoAsp discrimination and GLP-1 analog characterization. The 6230 TOF, 6475/6495 triple quadrupole and 6530 Q-TOF are separate instruments, not ExD variants, so they are selected for other MS workflows rather than ECD fragmentation.
The verified configuration pairs the cell with an Agilent Dual Jet Stream ESI source, a 120 µm column at 0.400 mL/min and 60 °C, and a 1290 Infinity II Bio LC in the application notes. Ion optics are capillary 4000 V, nozzle 2000 V, skimmer 75 V, fragmentor 175 V, nebulizer 35 psi, drying gas 10 L/min at 325 °C and sheath gas 11 L/min at 275 °C.
The verified set specifies positive polarity, Extended Dynamic Range acquisition, Medium isolation window, MS1 100–3,200 m/z and MS/MS 120–3,200 m/z, with processing thresholds of 2000 absolute and 0.01 relative intensity and 20 ppm mass error tolerance. Autosampler is held at 5 °C, sample storage at 20 °C, injection volume 10 µL, gradient 45–90. The documents give no duty-cycle or ambient limits.
The application notes name MassHunter with ExDControl and ExDViewer as the control and viewing software for the cell; the verified facts do not list these packages, certificates or any accessories as delivered items, so they must be confirmed on the order. No maintenance interval or spare-part schedule is stated in the available documents.