Agilent Technologies Electron capture dissociation for QTOF LCMS of proteins

Agilent Technologies Electron capture dissociation for QTOF LCMS of proteins — Liquid chromatography mass spectrometry lc ms with Pumping speed 0.024 m³/h.

The ExD cell is an electron-capture dissociation fragmentation module for the Agilent 6545XT AdvanceBio LC/Q-TOF, not a standalone instrument. It enables ECD of peptides and intact proteins in the 120–3,200 m/z range for isobaric Leu/Ile and Asp/isoAsp discrimination. It is specified here with the Dual Jet Stream ESI source, 120 µm column and 0.400 mL/min LC flow.

Pumping speed
0.024 m³/h

Agilent Technologies Quadrupole Time Of Flight LC MS Series — Model Comparison & Selection

Model Pumping speed, m³/hMass rangeAcquisition rate, HzAutosampler temperature, °CColumn temperature, °CSample volume, milliliter
Electron capture dissociation for QTOF LCMS of proteins Current 0.024—15600.01
6545XT AdvanceBio UHPLC QTOF, biopharmaceutical analysis 3×10⁻⁵100...10,0001.04605×10⁻⁴
6560 Ion Mobility QTOF LC/MS, Collision Cross Section 1.6×10⁻⁸100...1,70010445—

Full specifications

Core Performance & Functional Specifications
Pumping speed 0.400 mL/min
Acquisition Rate 1 spectrum/sec
Column temperature 60 °C
Drying Gas Flow 10 L/min
Ion source Agilent Dual Jet Stream ESI source
Sample volume 10 µL
Sheath Gas Flow 11 L/min
MS1 Spectra Range mfr 100...3,200 m/z
Polarity mfr Positive Positive
Nebulizer mfr 35 psi
Acquisition Mode mfr Extended Dynamic Range Range
Isolation Window mfr Medium Medium
MS Spectrum Range mfr 120...3,200
MS/MS Spectrum Range mfr 120...3,200
Intensity Threshold (Abs) mfr 2000
Intensity Threshold (Rel) mfr 0.01
Acquisition mode mfr Extended dynamic range range
Gradient mfr 35...36
Dimensions, Weight & Mechanical Design
Mass Error Tolerance mfr 20 ppm
Antibody molecular weight mfr 150 kDa
Electrical, Power & Drive Specifications
Capillary Voltage 4000 V
Nozzle Voltage 2000 V
Skimmer mfr 75 V
Mobile Phase A mfr 0.1 acid
Mobile Phase B mfr 0.1 acid
Fragmentor mfr 175 V
Operating Conditions, Environment & Protection
Autosampler Temperature 5 °C
Gas Temperature 325 °C
Sample Storage Temperature 20 °C
Sheath Gas Temperature 275 °C

Description

Construction and positioning

Behavior and modes

Operation

Integration & Operating Notes

Maintenance
Confirm software and source consumables are ordered with the cell

The verified facts list no certificates, no accessories and no maintenance intervals for the ExD cell. ExDControl and ExDViewer are named only in the application notes, so verify licensing and any source consumables against the order before installation; no service schedule can be stated from the available documents.

Application Notes 5994-7506EN, 5994-7994EN, 5994-9164EN

Selection & Integration Q&A

When should I choose the ExD cell configuration instead of another member of the Agilent LC/MS series?

Choose the ExD cell when the application needs electron-capture dissociation on a 6545XT AdvanceBio LC/Q-TOF, for example isobaric Leu/Ile or Asp/isoAsp discrimination and GLP-1 analog characterization. The 6230 TOF, 6475/6495 triple quadrupole and 6530 Q-TOF are separate instruments, not ExD variants, so they are selected for other MS workflows rather than ECD fragmentation.

What adjacent system parts and settings does the ExD cell configuration assume?

The verified configuration pairs the cell with an Agilent Dual Jet Stream ESI source, a 120 µm column at 0.400 mL/min and 60 °C, and a 1290 Infinity II Bio LC in the application notes. Ion optics are capillary 4000 V, nozzle 2000 V, skimmer 75 V, fragmentor 175 V, nebulizer 35 psi, drying gas 10 L/min at 325 °C and sheath gas 11 L/min at 275 °C.

What acquisition and sample-handling limits apply when running the ExD cell?

The verified set specifies positive polarity, Extended Dynamic Range acquisition, Medium isolation window, MS1 100–3,200 m/z and MS/MS 120–3,200 m/z, with processing thresholds of 2000 absolute and 0.01 relative intensity and 20 ppm mass error tolerance. Autosampler is held at 5 °C, sample storage at 20 °C, injection volume 10 µL, gradient 45–90. The documents give no duty-cycle or ambient limits.

What software and consumables are not included in the base delivery of the ExD cell?

The application notes name MassHunter with ExDControl and ExDViewer as the control and viewing software for the cell; the verified facts do not list these packages, certificates or any accessories as delivered items, so they must be confirmed on the order. No maintenance interval or spare-part schedule is stated in the available documents.