Agilent Technologies Pulsed-field CE technology, Femto Pulse system
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies Pulsed-field CE technology, Femto Pulse system

Agilent Technologies Pulsed-field CE technology, Femto Pulse system — Automated electrophoresis.

The Femto Pulse System is an automated pulsed-field capillary electrophoresis instrument built on the Fragment Analyzer platform, configured with a pulsed-field power supply and a 12-capillary array. It resolves DNA fragments up to 165 kb and quantifies inputs down to 50 fg/µL with ultra-sensitivity kits, separating 165 kb fragments in 1.5 hours. It serves as a QC station for HMW gDNA and long-read sequencing libraries, replacing manual PFGE with faster, quantitative sizing.

Full specifications

Core Performance & Functional Specifications
Analysis time 30 minutes
Average Smear Size (final Library) 7.7 kb
Centrifugation Speed 7600 rpm
Maximum Separable Dna Fragment Size 165000 bp
Maximum Separable Genomic Dna Size 165000 bp
Minimum Dna Fragment Input Concentration (ultra Sensitivity Kits) 50 fg/µL
Sample Amount Picograms
Sample Volume Per Well 2 µL
Separation Time For 165,000 Bp Fragments 1.5 hours
Size-selection Cutoff (example, Blue Pippin) 8 kb
Smear Analysis Upper Limit 165 kb
Samples per run mfr 1...14 samples
Total time (incl. gel prep., separation, and staining) mfr 12...26 hours
Size range mfr 10 Mb
Result format mfr Agarose gel image; requires manual annotation an
BAC insert size range mfr 100...300 kb
Parallel sample capacity mfr 12 samples
Maximum fragment size resolved mfr 165 kb
Sizing range mfr 1.3...165 kb
Quantification accuracy mfr 20
Quantification precision mfr 25 %CV
Electrophoresis method mfr Pulsed field field
Sizing precision (final library) mfr 6 less
Recommended input gDNA GQN threshold mfr 7.0 higher
Recommended gDNA shearing size mfr 10...25 kb
Maximum DNA sizing range mfr 165 kb
Size-selection cutoff method mfr 40 kb
Sample shearing device mfr g-TUBE TUBE
Mean read quality mfr 11.0
Median read quality mfr 11.2
Number of reads mfr 58413
Total bases mfr 973 millions
Sizing precision, final library mfr 6 less
gDNA shearing target size mfr 10...25 kb
Smear analysis lower limit mfr 400 bp
Speed advantage vs pulsed-field gel electrophoresis (PFGE) mfr 10 faster
Input concentration range (fragments) mfr 0.1 pg/μL
Input concentration range (smears) mfr 25 pg/μL
Kit size mfr 275 samples
Input concentration range (total RNA) mfr 15 pg/μL
Input concentration range (mRNA) mfr 25 pg/μL
Input concentration range (fragment up to 48 kb) mfr 3 pg/μL
Input concentration range (fragment <2 kb) mfr 1 pg/μL
Input concentration range (fragment <48 kb) mfr 1.6 pg/μL
Input concentration range (fragment >48 kb) mfr 3 pg/μL
Input concentration range (multiple frags) mfr 12.5 pg/μL
Sizing precision mfr 20 %CV
Recommended GQN threshold (input gDNA) mfr 7.0
Target sheared gDNA size mfr 10...25 kb
Ladder upper size (gDNA ScreenTape) mfr 48.5 kb
Sizing accuracy mfr 15
Number of reads above Q7 mfr 58409
Number of reads above Q10 mfr 47903
Number of reads above Q12 mfr 11682
Number of reads above Q15 mfr 5
Speed advantage versus PFGE mfr 10 faster
Sample dilution mfr single dilution dilution
Capillary arrays mfr 12 arrays
n–1 resolution mfr 60 nt
Samples separated per run mfr 12 samples
Samples per Run mfr 1...14
Total Time (Inc. Gel Prep., Separation, and Staining) mfr 12...26 hours
Size Range mfr 10 Mb
Result Format mfr Agarose gel image; requires manual annotation an
Digestion reaction volume mfr 20 μL
Sample dilution factor mfr 10 X
Diluent Marker volume mfr 18 μL
PFGE separation time mfr 10.5 hours
PFGE agarose gel concentration mfr 1
PFGE loaded sample volume mfr 20 μL
UV exposure wavelength mfr 365 nm
Kit name mfr 165 kit
Sample concentration range mfr 0.3...30 pg/μL
Femto Pulse run time mfr 1.5 hours
Femto Pulse sizing range mfr 165 kb
Fragment Analyzer run time mfr 70 less
TapeStation sample capacity mfr 96 samples
Femto Pulse loading concentration mfr 300 pg/μL
Fragment Analyzer loading concentration mfr 1 ng/μL
TapeStation loading concentration mfr 30 ng/μL
Femto Pulse gDNA smear lower limit mfr 400 bp
Femto Pulse ladder last fragment mfr 165 kb
Fragment Analyzer ladder last fragment mfr 48.5 kb
TapeStation gDNA ladder upper limit mfr 48.5 kb
TapeStation smear extrapolation limit mfr 60 kb
PacBio HiFi WGS shear target mfr 10...25 kb
needle gauge mfr 25 gauge
shear sample volume (needle) mfr 50 μL
shear sample concentration (needle) mfr 150 ng/μL
g-TUBE sample volume mfr 150 μL
g-TUBE sample concentration mfr 100 ng/μL
DNA input for library mfr 500 ng
sizing range mfr 165 kb
speed advantage vs PFGE mfr 10 faster
maximum queued samples mfr 288 samples
number of gel types mfr two gel types types
sample separation time mfr 30 minutes
samples per run mfr 12 samples
capillary array options mfr 12 arrays
resolution range mfr 60 nt
Dimensions, Weight & Mechanical Design
Median Read Length 8587 bp
Read Length N50 12152 bp
Mean read length mfr 36259.8 bp
Average read length mfr 7.2 kb
E. coli library mean HiFi read length mfr 19.0 kb
Human library mean HiFi read length mfr 7.2 kb
Standards, Safety & General Data
Maximum Extended Warranty 5 years
Standard Warranty 1 year
Maximum extended warranty time mfr five years total total
standard warranty period mfr one-year year

Description

Construction and series positioning

Behavior and performance envelope

Installation, control, and operation

Integration & Operating Notes

Process Limits
Input gDNA below GQN 7.0 compromises long-read library QC

The recommended input genomic DNA GQN threshold is 7.0; below this, sizing and quantification results for HMW libraries are not reliable. Verify GQN before shearing to 10–25 kb, since degraded starting material will not yield the 165 kb upper-range performance the instrument is specified for.

Application Note 5994-3078EN, Long-Read Sequencing Sizing
Process Limits
Shear gDNA to 10–25 kb before Femto Pulse sizing

The recommended gDNA shearing size is 10–25 kb using the g-TUBE device. Loading unsheared high-molecular-weight gDNA outside this window can exceed the sizing range or produce smears that are difficult to annotate; the 165 kb upper limit applies to resolved fragments, not to arbitrary input size distributions.

Application Note 5994-3078EN, Long-Read Sequencing Sizing
Maintenance
Replace the 12-capillary array per kit cycle

The Femto Pulse 12-Capillary Array is a consumable supplied separately from the instrument; kits are provided in 275-sample kit sizes. Plan array replacement and kit consumption together, because the capillary array is not part of the base instrument delivery and its condition directly affects sizing precision (6% CV for final libraries).

Data Sheet 5994-2452EN, Consumables and Analysis Kits
Control & I/O
Results require manual annotation and documentation

Output is an agarose gel image processed by ProSize software; the system does not automatically annotate or archive results. Integrate a documentation step into the workflow so that sizing and smear calls are traceable, especially when the instrument is used as a QC gate before sequencing.

Brochure 5994-0410EN, Femto Pulse System
Electrical
Pulsed-field power supply is integral, not an add-on

The pulsed-field capability is built into the instrument configuration; there is no separate external pulsed-field supply to site or connect. Electrical ratings are not stated in the supplied documents, so confirm facility requirements against the instrument's site preparation guide before installation.

Brochure 5994-0410EN, Femto Pulse System

Selection & Integration Q&A

When should I choose the Femto Pulse instead of a Fragment Analyzer or TapeStation for library QC?

Choose the Femto Pulse when fragments or gDNA exceed the sizing range of the 5200/5300/5400 Fragment Analyzer or 4150/4200 TapeStation systems: it resolves up to 165 kb and performs smear analysis from 400 bp to 165 kb. For routine NGS libraries below ~50 kb, the Fragment Analyzer or TapeStation is sufficient and the Femto Pulse's 10–24 h separation window is unnecessary.

What consumables and accessories must be ordered with the instrument, and which are not in the base delivery?

The base instrument does not include the 12-Capillary Array or analysis kits. Order the Femto Pulse 12-Capillary Array plus the appropriate kit: quantitative gDNA 165 kb, Ultra Sensitivity NGS, or Ultra Sensitivity RNA, or qualitative 55 kb BAC or 165 kb BAC kits, all in 275-sample sizes. ProSize software is part of the platform; CrossLab Silver service is an optional warranty upgrade.

What sample input and upstream preparation are required before running HMW gDNA on the Femto Pulse?

Input gDNA should have a GQN of at least 7.0 and be sheared to 10–25 kb with the g-TUBE device. Load 2 µL per well; ultra-sensitivity NGS kits accept down to 50 fg/µL. For BAC analysis, the 165 kb BAC kit covers 100–300 kb inserts. Size selection upstream (e.g., Blue Pippin at 8 kb cutoff) should be completed before the run.

Dimensional Drawings & Technical Documentation

Dimensional drawings

Pulsed-field CE technology, Femto Pulse system — drawing 1

Click drawing to inspect vector dimensions

Technical documentation

PDF
Bacterial Artificial Chromosome (BAC) Analysis
Brochure ·610,8 КБ ·6 pp.
View PDF
PDF
Quality Control in the PacBio HiFi Sequencing Workflow
Manual ·1,8 МБ ·9 pp.
View PDF
PDF
Comparison of Agilent Femto Pulse
Brochure ·418,1 КБ ·8 pp.
View PDF
PDF
Femto Pulse System
Brochure ·3,8 МБ ·12 pp.
View PDF
PDF
Build Consistency into Your Lab's Workflow
Brochure ·12,3 МБ ·12 pp.
View PDF
PDF
Agilent Femto Pulse Consumables
Datasheet ·143,1 КБ ·2 pp.
View PDF