No photo available yet

Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies Compact & Portable FTIR Systems, Mobile FTIR

Agilent Technologies Compact & Portable FTIR Systems, Mobile FTIR — Molecular spectroscopy.

The Agilent 4200 FlexScan is a handheld FTIR spectrometer for onsite molecular analysis, covering 5100–600 cm⁻¹ with a single-reflection ATR element (2.5 mm surface, 2.6 µm effective pathlength). Weighing 3.8 kg with a 25 mm optical aperture and 20 µL sample volume, it is the compact portable variant in the FlexScan/4300/4500/5500 series, intended for field identification of liquids and solids without sample preparation.

Agilent Technologies FTIR Spectroscopy Series — Model Comparison & Selection

Model Wavelength rangeSample volume, milliliterAtr path length, µmAtr surface diameter, mmEffective pathlength, µmOptical aperture, mm
Compact & Portable FTIR Systems, Mobile FTIR Current 5100...6000.022.62.52.625
Benchtop FTIR Instruments 5100...6000.022.62.52.625
FTIR Microscopes & Imaging Systems 5100...6000.022.62.52.625

Full specifications

Core Performance & Functional Specifications
Wavelength range 5100...600
Atr Surface Diameter 2.5 mm
Effective Pathlength 2.6 μm
Optical Aperture 25 mm
Sample volume 20 µL
Bench space required mfr 20 cm
ATR spectral range mfr 5100...600
Spectrometer Body mfr Glass-fiber reinforced polyamide for durability
Detector mfr High-sensitivity thermoelectrically cooled deute
Interferometer mfr 45 aperture
Bench space mfr 20 cm
Spectral range (KBr optics) mfr 7000...350
Spectral range (ZnSe optics) mfr 5100...600
DialPath path lengths mfr 30...1,000 microns
DialPath Modules mfr 5100...600
Sample Type mfr Lower-concentration components, more dilute solu
ZnSe engine spectral range mfr 5100...600
KBr engine spectral range mfr 7000...350
DialPath pathlength repeatability mfr 0.25 μm
DialPath custom pathlength mfr 1000 μm
TumblIR fixed pathlength range mfr 100 μm
Dimensions, Weight & Mechanical Design
Atr Path Length 2.6 μm
Weight 3.8 kg
Weight range 3.5 kg
ATR effective path length mfr 36.5
Footprint mfr 26.4 module
Materials, Media & Process Compatibility
ATR effective pH range mfr 1...14
ATR pH range mfr 5...9
ZnSe ATR pH range mfr 5...9

Description

Construction and series positioning

Optical and sampling behavior

Installation and operation

Integration & Operating Notes

Process Limits
ATR crystal limited to pH 5–9 samples

Samples outside pH 5–9 can attack the ATR element and degrade spectra; neutralize or dilute aggressive acids/bases before measurement, and verify crystal compatibility for any non-aqueous solvent not covered by the factory pH range.

Factory Specification Sheet, extra_specs 'ATR effective pH range'
Maintenance
Clean ATR crystal after each sample to prevent carryover

Residue on the 2.5 mm ATR surface contaminates subsequent spectra; wipe with a solvent compatible with the pH 5–9 window and dry before the next measurement. No automated cleaning or validated cleaning interval is specified in the supplied documents.

Factory Specification Sheet; document digests contain no maintenance schedule

Selection & Integration Q&A

When should I choose the 4200 FlexScan handheld instead of the 4300 or 4500 portable models?

Choose the 4200 when 3.8 kg handheld operation and a 20 µL ATR sample volume suit field work in the 5100–600 cm⁻¹ range. The 4300/4500/5500 siblings are not specified in the supplied facts; compare their weight, sampling interface, and spectral range before selecting for benchtop or high-throughput use.

What adjacent system parts are required to operate the 4200 FlexScan, and are they included?

The supplied facts list no electrical ratings, interface protocols, or included accessories. A power supply or battery, control computer/software, and any docking station are not confirmed as part of base delivery; verify the ordering configuration with Agilent before specifying the installation.

What environmental and duty-cycle limits apply to the 4200 FlexScan in the field?

No temperature, humidity, ingress-protection, or duty-cycle ratings are verified in the supplied facts. The only environmental constraint documented is the ATR pH 5–9 sample window; confirm operating environment and continuous-scan limits with the factory manual before deployment.

What maintenance and consumables does the 4200 FlexScan require, and what is not included?

The supplied documents contain no maintenance schedule, error codes, or consumables list. ATR crystal cleaning after each sample is implied by the pH 5–9 limit, but cleaning agents, replacement crystals, calibration standards, and cables are not confirmed as included; obtain the service plan from Agilent.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Agilent Cary 635 FTIR Spectrometer
Brochure ·4,1 МБ ·26 pp.
View PDF
PDF
Agilent Cary 635 FTIR
Brochure ·1,6 МБ ·10 pp.
View PDF