No photo available yet
Agilent Technologies Upgrade kits for HPLC injector improve functionality
Agilent Technologies Upgrade kits for HPLC injector improve functionality — Liquid chromatography.
The 1260 Infinity II GPC/SEC System is a high-performance liquid chromatography platform for gel permeation and size-exclusion separations. This injector-upgrade configuration is defined by its electrical interface: 100 V AC input at 50 Hz, 3 A input current, 200 W nominal power, and a 36 V DC / 5.55 A output stage. It is intended for integration into a complete GPC/SEC workflow where the injector module is specified separately from the base LC system.
Agilent Technologies HPLC Uhplc Upgrades Series — Model Comparison & Selection
| Model | Pumping speed, m³/h | Column particle size, µm | Depth, mm | Filter membrane pore size, µm | Flow cell path length, mm | Frequency, Hz |
|---|---|---|---|---|---|---|
| Upgrade kits for HPLC injector improve functionality Current | — | — | 795 | — | — | 50 |
| Infinity III LC upgrades | Upgrade existing HPLC/UHPLC systems | 3×10⁻⁵ | 1.8 | — | 0.22 | 10 | — |
Full specifications
| Nominal power | 200 W |
| Nominal power | 200 W |
| Depth | 795 mm |
| Height | 770 mm |
| Weight | 18.79 kg |
| Width | 1270 mm |
| Frequency | 50 Hz |
| Input Current | 3 A |
| Output current | 5.55 A |
| Output voltage | 36 V |
| Input voltage mfr | 100 AC |
| Input line voltage mfr | 100 V |
| Operating Altitude | 3000 m |
| Operating humidity range mfr | 95 condensing |
Description
Construction and positioning
- The model is catalogued under the 1260 Infinity II GPC/SEC series, a high-performance GPC/SEC platform. The injector-upgrade designation places it as a configuration layer rather than a standalone LC system; sibling models in the series include the 1220 Infinity II LC System, the 1220 Infinity II Analytical-Scale LC Purification System, the 1260 Amino Acid Analysis System, and the 1260 Analytical-Scale LC Purification System.
- Physical envelope: 1270 mm width, 795 mm depth, 770 mm height, 18.79 kg. These dimensions describe the delivered configuration, not a single benchtop module.
Electrical behavior
- Input side: 100 V AC line voltage at 50 Hz, 3 A input current, 200 W nominal power.
- Output side: 36 V DC at 5.55 A. The input and output ratings describe a power-conversion stage inside the configuration; they are not interchangeable supply requirements.
- Operating altitude is rated to 3000 m. Operating humidity is listed to 95% condensing; the temperature field is given only as a single 41 °F value and is therefore not restated here as a range.
Installation and operation
- The attached site-preparation checklists cover the PAL3 RTC 120 (G7370B) and RTC 160 (G7396B) autosampler modules and related tray-cooler and module hardware (G7383A/G7384A, G7369A, G7364A/G7365A). They are site-readiness documents, not operating manuals; no control-loop, firmware, or method details are available from the supplied digests.
- No digitized performance curves, certificates, or application notes were supplied for this model, so separation performance, pressure limits, and solvent compatibility are not asserted here.
Integration & Operating Notes
The configuration is rated for a 100 V AC, 50 Hz line with 3 A input current and 200 W nominal power. The 36 V DC / 5.55 A figures belong to the internal output stage and must not be used to size the facility supply. Confirm the site provides 100 V AC at 50 Hz before installation.
Selection & Integration Q&A
Pick this configuration when the GPC/SEC separation hardware is already specified and only the injector layer is being upgraded within the 1260 Infinity II series. Choose the 1220 Infinity II LC System for a complete analytical LC, or the 1260 Analytical-Scale LC Purification System when purification duty is the target.
A 100 V AC, 50 Hz line rated for 3 A and 200 W nominal is required; the 36 V DC / 5.55 A output is internal and not a facility supply. Autosampler integration follows the PAL3 RTC 120/160 site-preparation checklists, which cover the G7370B/G7396B modules and tray-cooler hardware.
The supplied documentation consists of PAL3 site-preparation checklists (D0130828, D0113215) covering autosampler modules and tray-cooler hardware. No cables, consumables, service-interval schedule, or error-code table were included in the supplied digests, so these must be confirmed with the vendor before commissioning.