Agilent Technologies Integrated Turbopumping Systems/Stations, TPS
Agilent Technologies Integrated Turbopumping Systems/Stations, TPS — Vacuum technologies.
The Agilent TPS-mini is a fully integrated, compact turbopumping station pairing a TwisTorr 70 L/s turbo pump with a 10 L/min dry backing pump. It is the smallest member of the TPS family, distinguished from the modular TPS-flexy and TPS-compact by its fixed 70 L/s turbo and integrated dry primary. It serves as a self-contained high-vacuum source for laboratory and analytical instruments requiring oil-free, vibration-limited pumping.
Agilent Technologies Turbo Pumping Systems Tps Series — Model Comparison & Selection
| Model | Backing pump pumping speed, liter/minute | Base pressure, mbar | Chamber volume, L | Input voltage, V | Power supply | Turbo pump pumping speed, L/s |
|---|---|---|---|---|---|---|
| Integrated Turbopumping Systems/Stations, TPS Current | 10 | 10 | 10 | 90 | 90 | 70 |
| Modular & Flexible Turbo Pumping Systems/Stations, TPS | 10 | 10 | 10 | 90 | 90 | 70 |
Full specifications
| Backing Pump Pumping Speed | 10 L/min |
| Base Pressure | 10 mbar |
| Chamber volume | 10 L |
| Turbo Pump Pumping Speed | 70 L/s |
| Roll-around cart with open structure mfr | Easy mobility and serviceability serviceability |
| High capacity systems mfr | Wide pumping speed range range |
| Large selection of gauges and accessories mfr | Gauge reading capability for any pressure range. |
| RS-232 or analog communication, pressure driven setpoint, analog setpoint mfr | Easy to use: easy PLC and PC interfacing interfa |
| Onboard fore-vacuum safety valve mfr | Full system protection against backstreaming in |
| Custimization Service available mfr | imum flexibility to build custom configuration o |
| Active gauge reading capability mfr | Can drive a wide range vacuum gauge, no need for |
| New generation turbomolecular pump TwisTorr 74 FS, backed by a dry 10 L/min diaphragm pump, inside the same case mfr | Integrated plug and pump dry vacuum system. Cost |
| RS-232 or analogical communication, pressure driven setpoint, analog setpoint mfr | Easy to use, easy PLC and PC interfacing interfa |
| Integrated IDP-3 dry scroll backing pump mfr | Very fast pumpdown time. time. |
| Easy scroll tip seal replacement (15 min) mfr | Adaptive scroll pump driving system system |
| Extended scroll pump tip seal life mfr | Gas Ballast Ballast |
| Easy system pressure monitoring mfr | 74 pumps |
| Excellent base pressure, down to 10-10 mbar mfr | Compact, light, dry, clean, and robust bench top |
| Worldwide power configurations, complies with worldwide safety standards mfr | -232 setpoint |
| TwisTorr 74FS mfr | Onboard controller controller |
| TwisTorr 305FS mfr | Remote controller controller |
| scroll tip seal replacement time mfr | 15 min |
| scroll pump operation time reduction mfr | 80 |
| Smallest footprint, lightest weight, compact, dry, clean, and robust system mfr | Direct mounting on customer’s system system |
| Input voltage | 90 V |
| Power supply | 90 V |
| Power supply | 90 V |
| Integrated large pressure data display mfr | Easy system pressure monitoring monitoring |
| Can drive a wide range vacuum gauge, no need for external gauge controller mfr | Integrated large pressure data display display |
| Plug and pump system, all-in-one, very simple use. Portable, fully integrated, hydrocarbon-free mfr | Nominal voltage - CE/CSA certified certified |
| Reduced humidity, for system performance optimization mfr | Active gauge reading capability capability |
| Voltage 110/230V. All systems are CE certified. mfr | Worldwide power configurations, complies with wo |
| Universal voltage (90 V-240 V) - CE/CSA certified mfr | Worldwide power configurations, complies with wo |
| Easy to use: easy PLC and PC interfacing through A-PLUS software. mfr | Wheels option available available |
Description
Construction and series positioning
- The TPS-mini is a single integrated station: TwisTorr 70 L/s turbomolecular pump directly coupled to a 10 L/min dry primary pump, supplied as one unit.
- Within the TPS family it is the fixed-configuration, lowest-throughput variant; the TPS-compact offers 70 or 300 L/s turbo stages with an IDP-3 scroll backing pump, the TPS-flexy allows selection of IDP-3, IDP-7 or MD-1 backing pumps, and TPS-mobile spans 70–550 L/s with dry scroll or oil-sealed primaries.
- Choose the TPS-mini when the required gas load is matched by 70 L/s turbo speed and 10 L/min backing; move to TPS-compact or TPS-flexy when higher turbo speed or a different backing-pump technology is needed.
Working behavior
- The 70 L/s turbo stage and 10 L/min backing stage define the usable pumping window; the backing speed sets the maximum throughput the station can sustain before the foreline pressure rises.
- No digitized curve points were supplied, so pressure-versus-throughput behavior must be taken from the TwisTorr 70 and dry-pump datasheets rather than interpolated here.
Electrical and control
- The matched electrical facts list a 90 V input; this is the only electrical value available and should be confirmed against the nameplate of the specific unit before connection.
- No control, I/O or interface facts were provided in the verified data; controller and cabling requirements must be taken from the TPS-mini instruction manual.
Integration & Operating Notes
The verified data lists a 90 V input, but no frequency, phase or current rating is given. Verify the actual nameplate of the delivered TPS-mini against the site supply and provide a protective device sized to the unit's rated current; do not assume the 90 V figure applies to every build.
The dry backing pump moves 10 L/min, which caps the throughput the 70 L/s turbo stage can sustain before foreline pressure rises and compression degrades. Estimate the process gas load and keep it within the backing stage's capacity, or select a TPS variant with a larger primary pump.
Selection & Integration Q&A
Pick the TPS-mini when a fixed 70 L/s turbo with a 10 L/min dry backing pump covers the gas load and no backing-pump choice is needed. Move to TPS-compact for 300 L/s turbo speed or TPS-flexy when IDP-7 or MD-1 backing pumps are required.
The verified data gives only a 90 V input with no frequency, phase or current. Check the delivered unit's nameplate against the site supply and size the protective device to its rated current; do not assume 90 V applies to every build.
The 10 L/min dry backing pump sets the ceiling: once foreline pressure rises under high gas load, turbo compression falls. Estimate the chamber gas load against this backing capacity; if it exceeds it, select a TPS variant with a larger primary pump.
The dry primary pump is the wear item and governs service intervals; obtain the TPS-mini manual for bearing and seal schedules and controller service counters. Controller cabling and inlet flange hardware are not confirmed as included and must be specified separately.