Agilent Technologies 5 Laser Flow Cytometer, NovoCyte Penteon

Agilent Technologies 5 Laser Flow Cytometer, NovoCyte Penteon — Research flow cytometry.

The NovoCyte Penteon is a five-laser solid-state flow cytometer with onboard thermoelectric cooling, built for high-parameter research acquisition. It pairs a 6.5 mL/min sheath flow with a 5–120 µL/min sample flow and up to 100,000 events/s, distinguishing it from the one-to-three-laser Advanteon and four-laser Quanteon siblings.

Agilent Technologies Flow Cytometer Systems Series — Model Comparison & Selection

Model Pumping speed, m³/hSample flow rate, µL/minSheath flow rate, mL/minVolumetric absolute count precision, %Laser power, WPrint technology
5 Laser Flow Cytometer, NovoCyte Penteon Current —5...1206.550.405Solid state laser with o
1,2, or 3 Laser Benchtop Flow Cytometer, NovoCyte Advanteon  —5...1206.550.405Solid state laser with o
1-3 laser benchtop flow cytometer, NovoCyte 3×10⁻⁶5...1206.55——
4 Laser Flow Cytometer, NovoCyte Quanteon —5...1206.550.405Solid state laser with o

Full specifications

Core Performance & Functional Specifications
Laser power 405 mW
Print technology Solid state laser with onboard thermal-electric cooling
Sample Flow Rate 5...120 μL/min
Sheath Flow Rate 6.5 mL/min
Ssc Sensitivity 0.1 μm
Volumetric Absolute Count Precision 5 %
Laser beam profile mfr 10 μm
Fluorescence detection mfr Silicon photomultiplier with individual photodet
FSC sensitivity mfr 0.4 μm
Fluorescence threshold sensitivity mfr 40 MESF
Fluorescence resolution mfr 3 % CV
Flow cell mfr 170 μm
Sample acquisition rate mfr 100000 events/second
Sample acquisition volume mfr 5 mL
Manual sample format mfr 12 tube

Description

Architecture and series positioning

Measurement behavior

Operation and control

Integration & Operating Notes

Process Limits
Acquisition above 100,000 events/s exceeds the specified rate

The 100,000 events/second figure is the stated sample acquisition rate ceiling. Samples concentrated enough to demand more than this will be acquired outside specification, so dilute high-concentration preparations or accept that data beyond the limit is not covered by the rated performance.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the Penteon rather than the Quanteon or Advanteon?

Pick the Penteon when the panel needs five laser lines; the Quanteon covers four and the Advanteon one to three. All three share the datasheet, so move down the series only when the extra laser line is not required by the panel.

What sample-delivery and sheath infrastructure must be in place before installation?

The fluidics expect a 6.5 mL/min sheath flow and a sample flow adjustable over 5–120 µL/min, with 12-tube manual loading and 5 mL acquisition volume. Sheath and waste containers sized for continuous 6.5 mL/min draw are required; the datasheet gives no pressure or tubing-fit values.

What duty-cycle and environment limits apply to continuous high-rate acquisition?

Acquisition is rated to 100,000 events/s with 5 % volumetric count precision. The supplied datasheet contains no ambient temperature, humidity or duty-cycle figures, so continuous-run limits and room cooling must be confirmed from the instrument manual before scheduling long runs.

What maintenance items and accessories are not included in the base delivery?

The supplied documents list no maintenance kit, sheath fluid, cleaning solutions, tubes or cables as included. Consumables and the service schedule are absent from the datasheet; obtain the accessory list and interval table from the Penteon manual or Agilent before budgeting.