Agilent Technologies CE-SDS Protein Analysis Capillary Array, ProteoAnalyzer
Agilent Technologies CE-SDS Protein Analysis Capillary Array, ProteoAnalyzer — Automated electrophoresis.
The CE-SDS Protein Analysis Capillary Array is the consumable separation array for the Agilent ProteoAnalyzer system, a parallel capillary electrophoresis instrument. It supports denaturing protein sizing from 10 to 240 kDa across 12 capillaries in parallel, with a 3-log dynamic range and CCD-based detection. The array is the replaceable separation element that defines the system's CE-SDS analysis capability.
Agilent Technologies Proteoanalyzer Systems Series — Model Comparison & Selection
| Model | Sensitivity | Run time, min | Software | Analysis time for 12 samples, minutes | Detector type | Lower marker size, kDa |
|---|---|---|---|---|---|---|
| CE-SDS Protein Analysis Capillary Array, ProteoAnalyzer Current | — | 30 | Agilent ProSize data ana | 30 | charge-coupled device | — |
| Protein Capillary Electrophoresis Instrument | 1 | 30 | — | — | — | 6 |
Full specifications
| Analysis Time For 12 Samples | 30 minutes |
| Detector type | charge-coupled device camera |
| Run Time | 30 minutes |
| Software | Agilent ProSize data analysis software |
| Protein size range mfr | 10...240 kDa |
| Samples analyzed in parallel mfr | 12 samples |
| Dynamic range mfr | 3 log |
| Separation technique mfr | automated parallel capillary electrophoresis sod |
| Sample plate format mfr | 96 plate |
| Protein size separation range mfr | 10...240 kDa |
| Capillary cleaning mfr | automatic cleaning, reconditioning and refilling |
| protein size range mfr | 10...240 kDa |
| dynamic range mfr | 3 log |
| parallel sample capacity mfr | 12 samples |
| sample plate format mfr | 96 plate |
| sample drawers mfr | three three |
| Standard Warranty | one-year |
Description
Construction and series positioning
- The array is a multi-capillary CE-SDS separation consumable, not a standalone instrument; it is the replaceable capillary element of the ProteoAnalyzer system bundle (instrument, array, software, computer, installation).
- Within the series, the sibling model is the Protein Capillary Electrophoresis Instrument itself; the array is the consumable that enables the instrument's denaturing protein electrophoresis function.
- The array is specified for 12 parallel capillaries, matching the system's 12-sample parallel analysis and 96-well plate sample format.
Separation behavior and working range
- Separation technique is CE-SDS (capillary electrophoresis with sodium dodecyl sulfate) for denatured proteins.
- Protein size range covered is 10–240 kDa, with a 3-log dynamic range.
- Detection is via CCD camera in the instrument; the array provides the separation channel set.
- Analysis time for 12 samples is 30 minutes under the system's standard run.
Installation and operation
- The array is part of the system bundle and is installed as part of instrument setup; the brochure scope includes installation and introduction.
- No additional electrical, control, or media specifications are provided for the array itself; these belong to the instrument platform.
- No certificates or applications are listed in the verified facts.
Integration & Operating Notes
The array is supplied as part of the ProteoAnalyzer system bundle and is not described as compatible with other capillary electrophoresis instruments. System-level integration (detector, sample plate handling, software) is provided by the instrument; the array should not be treated as a universal CE consumable.
The array's specified working range is 10–240 kDa for denatured proteins. Samples outside this range are not covered by the verified specification; sizing accuracy and detection may be invalid outside the stated range. The 3-log dynamic range applies within this size window.
The verified facts do not specify a replacement interval, cleaning procedure, or storage condition for the array. Users should follow the instrument's installation and introduction documentation for array handling; no maintenance schedule is available in the provided sources.
Selection & Integration Q&A
The array is a consumable separation element, not an instrument. Choose the array when you already have the ProteoAnalyzer instrument and need to run CE-SDS denaturing protein analysis (10–240 kDa, 12 samples in parallel). The sibling instrument is the platform itself; the array is ordered as its replacement separation component.
The array operates only within the ProteoAnalyzer system bundle, which includes the instrument, software, computer, and installation/introduction. The array itself does not include the instrument, detector (CCD camera), sample plate handling, or software. Confirm the platform is present before ordering the array as a consumable.
No mounting, environmental, or duty-cycle limits are specified for the array in the verified facts. Installation and introduction are part of the system bundle; operational limits are governed by the ProteoAnalyzer instrument. The array should be installed per the system's installation documentation.
No replacement interval, cleaning protocol, or storage condition is stated in the verified facts. The array is a replaceable consumable; the base system bundle includes the array, instrument, software, computer, and installation. Additional arrays, reagents, and sample plates are not described as included and should be ordered separately per the system documentation.