No photo available yet
Agilent Technologies Fast Roughing Roots Pumping Station 1400 m3/h; RPS-1401/301
Agilent Technologies Fast Roughing Roots Pumping Station 1400 m3/h; RPS-1401/301 — Vacuum technologies.
The RPS-1401/301 is a fast roughing Roots pumping station rated at 1400 m3/h, positioned between the 1000 m3/h high-speed and 2000 m3/h fast-roughing siblings in the RPS series. It is built for high-throughput roughing of large vacuum chambers where short pump-down cycles matter, using a Roots stage backed by a rotary-vane or dry-scroll forepump.
Agilent Technologies Roots Pumping Systems Rps Series — Model Comparison & Selection
| Model | Diffusion pump pumping speed, L/s |
|---|---|
| Fast Roughing Roots Pumping Station 1400 m3/h; RPS-1401/301 Current | 50 |
| High Speed Rotary Pumping Station 4000 m3/h; RPS-4001/631 | 50 |
Full specifications
| Diffusion Pump Pumping Speed | 50 L/s |
| Vacuum gauge measurement range mfr | 6 pressure |
| Dry scroll pump typical size mfr | 3...30 h |
| Turbomolecular pump pumping speed mfr | 70...3 L/s |
| Turbomolecular pump controller protection class mfr | 54 |
Description
Construction and series positioning
- The RPS-1401/301 is a two-stage roughing station: a Roots blower (1400 m3/h class) on a backing pump, configured as a fast roughing station rather than the high-speed RPS-1001/301 (1000 m3/h) or the larger RPS-2001/631 (2000 m3/h).
- Sibling models in the series span 500, 1000, 1400, 2000 and 4000 m3/h classes; the 1401/301 sits in the middle of the fast-roughing range, above the 500 m3/h RPS-501/301 and below the 2000 m3/h RPS-2001/631.
- The only matched performance spec is a diffusion-pump pumping speed of 50 L/s, which is a system-level figure, not the Roots stage rating.
Behavior and media
- No digitized curve points were supplied for this model, so pressure-versus-throughput behavior cannot be plotted from verified data; sizing should rely on the factory performance curve for the 1401/301 configuration.
- The station is intended for rough vacuum duty ahead of high-vacuum stages (diffusion or turbomolecular pumps), not for fine vacuum operation itself.
Installation and operation
- The attached brochures are application-level e-mobility documents and contain no model-specific installation, connection or control facts for the RPS-1401/301; wiring, flange and controller details must come from the model instruction manual.
- Extra factory specs in the source data (vacuum gauge range, dry scroll pump sizes, turbomolecular pump speeds and controller protection class) describe other product families and are not specifications of this station.
Integration & Operating Notes
The only matched performance value is a 50 L/s diffusion-pump pumping speed, a system-level number. The Roots station itself is a 1400 m3/h class roughing unit; using 50 L/s for roughing-line sizing would undersize the foreline and the backing pump.
The supplied documents do not state the inlet or exhaust flange standard for the RPS-1401/301. Before ordering mating hardware, verify the flange size and bolt pattern in the model instruction manual rather than assuming compatibility with other RPS sizes.
Roots blowers in roughing stations are typically enabled only after the backing pump has pulled the chamber below a preset pressure; the start-pressure threshold and interlock logic for the 1401/301 are defined in the model manual and must be wired into the pump-down sequence.
Selection & Integration Q&A
Pick the 1401/301 when the required roughing throughput falls between the high-speed RPS-1001/301 (1000 m3/h) and the fast-roughing RPS-2001/631 (2000 m3/h). If cycle time dominates, the 2000 m3/h unit gives more margin; if floor space or backing-pump size is the constraint, the 1000 m3/h high-speed unit is the closer fit.
The station is a Roots stage on a backing pump; the foreline must be sized for the backing pump's exhaust, and the Roots stage must be enabled only below its start pressure. Confirm the backing-pump model, inlet flange and exhaust routing against the RPS-1401/301 manual, since the supplied brochures give no connection data.
The supplied documents contain no model-specific mounting or duty-cycle data for this station. Installation position, ambient temperature limits and maximum continuous operating pressure must be taken from the RPS-1401/301 instruction manual; do not infer them from the e-mobility brochures, which cover product families only.
The verified facts list no accessories, cables or consumables for this model. Backing-pump oil, inlet flange seals and any controller cabling should be treated as separate items and confirmed against the RPS-1401/301 manual and order code; maintenance intervals are likewise manual-defined, not brochure-defined.