Agilent Technologies Live cell analysis, RTCA Analyzers
Agilent Technologies Live cell analysis, RTCA Analyzers — Cell analysis.
The Agilent xCELLigence RTCA analyzer is a label-free, impedance-based real-time cell analysis instrument available in Dual Purpose (DP), Single Plate (SP), Multiple Plate (MP), High Throughput (HT) and eSight configurations. The verified throughput fact specifies 48 wells, tying this card to the 48-well plate format. It is used for continuous, quantitative monitoring of cell proliferation, cytotoxicity and antibody internalization assays in cancer immunotherapy and water toxicology workflows.
Full specifications
| Throughput | 48 wells |
| Oncolytic viruses mfr | 40 |
| Selected publications mfr | 50 |
| T Cell-mediated cytolysis mfr | 44 |
| biosensor surface coverage mfr | 75 |
| 96-well plate read time mfr | 15 seconds |
| independent plates mfr | six plates plates |
| DP format mfr | 3 wells |
| SP format mfr | 1 wells |
| MP format mfr | 6 wells |
| HT format mfr | 1 wells |
| eSight impedance format mfr | 3 wells |
| eSight imaging format mfr | 5 wells |
| SP maximum throughput mfr | 96 wells |
| MP maximum throughput mfr | 576 wells |
| eSight impedance throughput mfr | 288 wells |
| Liquid tumor killing assays mfr | 48 |
Description
Construction and series positioning
- The xCELLigence RTCA platform is a real-time cell analyzer family; the verified document set names five instrument variants: Dual Purpose (DP), Single Plate (SP), Multiple Plate (MP), High Throughput (HT) and eSight.
- The only verified performance fact for this card is a 48-well throughput, which defines the plate format handled here; no other electrical, mechanical or interface specifications were supplied.
- The eSight variant is the only one documented with an imaging readout in addition to impedance: the antibody internalization application note pairs eSight with CypHer5E-NHS-ester labeling.
Measurement principle and behavior
- Detection is impedance-based and label-free: cells adhering to the plate electrode array change the measured impedance, which is recorded continuously over the assay.
- The water cytotoxicology application note describes an EDA workflow (steps 1–2) with HepG2 cells, indicating that assay design and data analysis are performed in software alongside the instrument.
- The immunotherapy handbook covers real-time cell analysis applications across the DP, SP, MP, HT and eSight variants; no curve points or dynamic ranges were supplied for this model.
Operation and documentation
- The supplied documents are application notes and a handbook, not an instrument manual; installation, connection and control specifics are therefore not verifiable from the provided facts and are not stated here.
Integration & Operating Notes
Because detection is impedance-based and label-free, only cells that attach and spread on the plate electrodes generate a measurable signal; suspension or non-adherent formats require an appropriate coating or a different readout. Confirm adhesion behavior for the chosen cell line before committing to an impedance-only workflow.
The cytotoxicology note documents an EDA workflow with defined steps, meaning plate layout, schedule and data evaluation are configured in software rather than on the instrument alone. Plan for a workstation and software installation alongside the analyzer when scoping the laboratory integration.
Selection & Integration Q&A
The verified throughput fact for this card is 48 wells, so it fits mid-scale impedance assays. Choose eSight only if you also need the imaging readout used in the CypHer5E antibody internalization workflow; the DP, SP, MP and HT variants differ in plate handling and are documented only by name in the supplied handbook, so their capacities must be confirmed separately.
The eSight-based internalization protocol requires CypHer5E-NHS-ester labeling dyes and HER2-positive lines such as MCF7, SKBR3 or BT474, demonstrated with CypHer5E-labeled trastuzumab and CypHer5E-Fab secondary labeling. Confirm that the imaging-capable eSight variant, not an impedance-only unit, is the one specified for this readout.
The supplied documents are application notes and a handbook and contain no installation, environmental or duty-cycle specifications for this model. These limits cannot be stated from the verified facts and must be taken from the instrument manual before siting the unit or planning continuous long-term runs.
No service intervals, cables, plate adapters or consumable lists are given in the supplied application notes or handbook. The base delivery contents and maintenance plan are therefore unverified for this configuration and should be requested from Agilent together with the instrument manual before purchase.