The Agilent Spin Concentrator is a single-use centrifugal filtration device for abundant protein depletion, characterized by a 1.5 nm hydrodynamic radius cutoff and a 243 Da molecular weight limit. It is supplied as one unit and is intended for sample preparation prior to BioHPLC analysis. No electrical, pressure, or temperature ratings are specified in the verified data.

Full specifications

Core Performance & Functional Specifications
Hydrodynamic Radius 1.5 nm
Quantity mfr 1 g
Dimensions, Weight & Mechanical Design
Molecular weight mfr 243 Da

Description

Construction and positioning

Behavior and media

Installation and operation

Integration & Operating Notes

Process Limits
Do not exceed the stated 1.5 nm hydrodynamic radius boundary

The only verified separation limit is a 1.5 nm hydrodynamic radius. Because no molecular weight cutoff is confirmed for this device, users must validate retention and passage against their own sample before relying on the 243 Da figure, which is listed as a separate molecular weight value and may not represent the membrane cutoff.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose this spin concentrator instead of another abundant protein depletion product in the series?

No sibling models are listed in the verified data, so a direct series comparison cannot be made. The only differentiator available is the 1.5 nm hydrodynamic radius; select this device when that size boundary matches your sample, and confirm the 243 Da molecular weight value against the product label before use.

What centrifuge and collection hardware must be paired with this device?

The verified facts do not specify rotor type, maximum g-force, or collection tube format. The catalog digest contains no actionable integration facts for this model. Confirm the required centrifuge adapter and tube compatibility from the product label or a current Agilent datasheet before ordering, since no accessories are listed in the base quantity of 1.

What are the mounting and duty-cycle limits for this spin concentrator?

No mounting, temperature, or duty-cycle limits are present in the verified data or the catalog digest. The document digest lists no sections or engineering facts for this model. Operating limits must be taken from the physical product insert; do not assume centrifugation speed or temperature ratings from this card.

What maintenance schedule and consumables are required, and what is not included in the base delivery?

The verified data lists quantity 1 g and no certificates, applications, or accessories. The catalog digest contains no ordering codes or consumable lists. No service interval is stated. Treat the device as single-use unless the product insert says otherwise, and source collection tubes and buffers separately.