Agilent Technologies NovoSampler Pro
Agilent Technologies NovoSampler Pro — Metrology, Analytical & Laboratory Instrumentation.
The NovoSampler Pro is an automated sample loader for the NovoCyte flow cytometer, accepting a 24-position rack of 12 × 75 mm tubes or 96-, 48-, and 24-well plates. It performs programmable mix and rinse cycles (1 cycle, 10 s mix) at a 66 µL/min sample flow rate with a 10 µL sampling volume. It is used to automate sample acquisition from multi-well plates and tube racks in flow cytometry workflows.
Full specifications
| Mix Cycles | 1 cycles |
| Mixing Duration | 10 s |
| Operating system | Microsoft Windows® |
| Rinse Cycles | 1 cycles |
| Sample Flow Rate | 66 µL/min |
| Sample volume | 90 plates |
| Sampling Volume | 10 µL |
| Software | NovoExpress |
| Supported tube rack mfr | 24 tubes |
| Supported sample plate type mfr | 96 plates |
| Minimum sample volume, 96-well V-bottom mfr | 90 μL |
| Dead volume, 96-well V-bottom mfr | 50 μL |
| Minimum sample volume, 96-well U-bottom mfr | 90 μL |
| Dead volume, 96-well U-bottom mfr | 50 μL |
| Minimum sample volume, 48-well plates mfr | 210 μL |
| Dead volume, 48-well plates mfr | 170 μL |
| Minimum sample volume, 24-well plates mfr | 310 μL |
| Dead volume, 24-well plates mfr | 270 μL |
| Minimum Sample Volume (96-well V-bottom) mfr | 90 μL |
| Dead Volume (96-well V-bottom) mfr | 50 μL |
| Minimum Sample Volume (96-well U-bottom) mfr | 90 μL |
| Dead Volume (96-well U-bottom) mfr | 50 μL |
| Minimum Sample Volume (48-well) mfr | 210 μL |
| Dead Volume (48-well) mfr | 170 μL |
| Minimum Sample Volume (24-well) mfr | 310 μL |
| Dead Volume (24-well) mfr | 270 μL |
| NovoCyte Flow Cytometer with NovoSampler Pro installed: Work space requirements (W × D × H) mfr | 186 cm |
| Carryover rate mfr | 0.1 |
| Mix mode mfr | orbital shaker shaker |
| Dead volume mfr | 50 plates |
| I. mfr | Revision History History |
| II. mfr | Contact Information Information |
| III. mfr | Trademark Trademark |
| IV. mfr | Intended Use Use |
| V. mfr | Using this Guide Guide |
| VI. mfr | Conventions Conventions |
| VII. mfr | Safety and Limitations Limitations |
| VIII. mfr | Technical Support Support |
| Appendix A mfr | Accessories and Consumables Consumables |
| Appendix B mfr | Technical Specifications Specifications |
| QC dilution buffer volume mfr | 1 mL |
| QC particles transfer volume to well mfr | 150 μL |
| Single sample volume in well A2 mfr | 150 μL |
| FSC-H threshold mfr | 100000 |
| Lymphocyte gate stop condition mfr | 5000 events |
| Automatic shutdown countdown mfr | 60 seconds |
| SIP collision auto-recovery time mfr | 3 minutes |
| Laser self-test duration mfr | 5...10 minutes |
| NovoSampler Pro Dimension (W × D × H) mfr | 14.6 in |
| NovoSampler Pro Weight mfr | 19.8 lb |
| Power requirements mfr | 100...220 W |
| Operating temperature | 15 °C |
| Operating Humidity mfr | 80 condensing |
Description
Construction and positioning
The NovoSampler Pro is a dedicated automation accessory for the NovoCyte flow cytometer, not a standalone instrument. It is the only sampler variant described in the operator's guide, and it supports a single tube-rack format: 24 positions for 12 × 75 mm tubes. Plate support covers 96-, 48-, and 24-well formats, so the modification is defined by its plate/tube handling rather than by any electrical or environmental rating in the verified facts.
Sample handling behavior
Sampling is defined by a 10 µL sample volume drawn at 66 µL/min, with one mix cycle of 10 s and one rinse cycle. The minimum sample volume and dead volume depend on the plate format: 96-well V- and U-bottom plates require 90 µL minimum with 50 µL dead volume; 48-well plates require 210 µL with 170 µL dead; 24-well plates require 310 µL with 270 µL dead. These values set the practical lower bound on well fill for reliable aspiration.
Installation and operation
The operator's guide covers hardware overview, installation, software control, sample acquisition, cleaning, and troubleshooting. Control is via software, and the unit is integrated with the NovoCyte cytometer. No electrical, environmental, or compliance specifications are given in the verified facts, so supply and site requirements must be taken from the full manual.
Integration & Operating Notes
For 96-well plates the dead volume is 50 µL and the minimum sample volume is 90 µL; for 48-well plates 170 µL dead and 210 µL minimum; for 24-well plates 270 µL dead and 310 µL minimum. Filling below the minimum risks aspirating air and losing the acquisition.
The operator's guide states that only the NovoSampler 24 tube rack for 12 × 75 mm tubes is supported. Other tube sizes cannot be loaded, so tube-based workflows must use this format or move to plate-based sampling.
Mix cycles, rinse cycles, sampling volume, and flow rate are set through the software control described in the operator's guide. The sampler has no independent front-panel programming described in the verified facts.
The guide includes a cleaning section and defines one rinse cycle per acquisition. Carryover between samples is limited by that rinse; the cleaning procedure should be followed between runs and during troubleshooting.
Selection & Integration Q&A
The verified facts list no sibling sampler variants, so selection is driven by format: choose it when you need 96-, 48-, or 24-well plate sampling or a 24-position 12 × 75 mm tube rack. If your workflow uses other tube sizes, this unit does not support them.
It is an accessory to the NovoCyte flow cytometer and is controlled through the cytometer software. The verified facts give no separate electrical or fluidic interface specification, so the cytometer connection and supply requirements must be confirmed in the full operator's guide before installation.
The operator's guide defines a rinse cycle (one per acquisition) and a cleaning procedure for carryover and troubleshooting. The verified facts do not list cables, racks, or cleaning solutions as included, so rack and cleaning consumables should be ordered separately and the guide consulted for the schedule.