Agilent Technologies PVG 500 Pirani Gauge

Agilent Technologies PVG 500 Pirani Gauge — Vacuum gauges.

The PVG-500 is a Pirani thermal-conductance vacuum gauge with a tungsten filament, covering 5×10⁻⁴ to 1000 mbar for air, O₂, CO and N₂. It is the base DN 16 ISO-KF variant without switching functions, distinguished from the PVG-502 by filament material and from S-suffixed siblings by the absence of setpoint relays. It serves as a compact, low-power pressure sensor in rough-to-medium vacuum control loops.

Full specifications

Core Performance & Functional Specifications
Measurement range 5 mbar
Electrical connection 68 male
Internal Volume 1.5 microliter
Operation 5
Repeatability 2 reading
Resolution 1 reading
Response Time 80 ms
Vacuum connection 80 millimeter
Measurement principle mfr thermal conductance according to Pirani Pirani
Accuracy (N2) mfr 50 reading
Output impedance mfr 2
Minimum loaded impedance mfr 10
Gauge identification mfr 27.0 common
Adjustment mfr one tactile switch for ATM and HV adjustment adj
Switching function setting range mfr 2 mbar
Switching function hysteresis mfr 10 threshold
Relay contact rating mfr 30 floating
Ripple mfr 1
Sensor cable mfr 68 male
Grounding concept mfr 1 conduct
Materials exposed to vacuum mfr 1.4301 NiFe
Admissible pressure mfr 10 gases
Use mfr 2000 NN
Measurement signal equation constant c mfr 6.143
Calibration factor C mfr 0.7
Switching functions setting range mfr 2 mbar
Switching functions hysteresis mfr 10 threshold
Relay contact mfr 30 floating
At gauge mfr 14
Vacuum connection to signal common mfr 1
Supply common to signal common mfr conducted separately, for differential measureme
Storage mfr 20
Product Description mfr 15
Technical Specifications mfr 16
PVG-500 and PVG-502 Outline mfr 18
Measurement Signal vs. Pressure mfr 19
Installation mfr 21
Power Connection mfr 23
Adjusting the Gauge mfr 25
Switching functions mfr 26
Adjusting the Setpoints mfr 27
Deinstallation mfr 28
Maintenance, Repair mfr 29
Accessories and Spare Parts mfr 30
About this manual mfr 6
Validity mfr 6
Definitions and terminology mfr 7
Definition of Caution, Warning and Note mfr 7
Warning Symbols mfr 8
Safety mfr 9
Proper use mfr 9
Improper use mfr 10
Safety guideline for PVG-500 and PVG-502 mfr 11
Disposal mfr 12
Service mfr 13
He mfr 0.8
Ne mfr 1.4
Ar mfr 1.7
Kr mfr 2.4
Xe mfr 3.0
Setpoint setting range mfr 2 mbar
ATM adjustment default mfr 1000 mbar
HV adjustment default mfr 1.2 mbar
Dimensions, Weight & Mechanical Design
Cable length 100 m
Weight 80 g
Mounting orientation mfr any any
Electrical, Power & Drive Specifications
Power consumption 1 W
Voltage vs. pressure mfr 1.286 V/decade
Supply voltage at gauge mfr 14 VDC
Current consumption mfr 500
Fuse required mfr 1
Fuse required 1) mfr 1
Setpoint voltage range mfr 2.67 VDC
Interfaces, Connections & Control
Output signal measurement range mfr 1.9 VDC
DN 16 ISO-KF mfr 80
DN 16 CF-R mfr 100
Materials, Media & Process Compatibility
Filament rupture signal mfr 0.1 V
Filament mfr 110
Gas Type Dependence mfr 24
Operating Conditions, Environment & Protection
Protection rating 40
Relative humidity mfr 80 °C

Description

Construction and series positioning

Measurement behavior

Installation and operation

Integration & Operating Notes

Electrical
Supply must be SELV and fused with a 1 A slow-blow fuse

The gauge is designed only for a grounded SELV supply with a 1 A slow-blow fuse in the feed. Connecting to a non-SELV or unfused source removes the protective separation and can damage the electronics or create a shock hazard in fault conditions.

Technical Specifications / p.17; Power Connection
Process Limits
Do not exceed 10 bar absolute or use with flammable mixtures

The admissible pressure is 10 bar absolute and is limited to inert gases. The filament reaches 110 °C and can ignite flammable or combustible gas mixtures with oxidants within the explosion range, so such service is prohibited regardless of pressure.

Technical Specifications / p.17; Product Description
Control & I/O
Measurement signal is valid only after 10-minute stabilization

After supply voltage is applied, the measurement signal is available between pins 3 and 5, but at least 10 minutes stabilization is required before readings are meaningful. Interlocks or process starts driven by this signal should be inhibited during that period; continuous operation is advisable irrespective of pressure.

Operation / p.24
Maintenance
Replace the sensor if contamination causes drift or malfunction

The gauge is factory-calibrated but zero drift can occur from long operation or contamination. ATM and HV adjustments can restore calibration; if contamination is severe or the gauge malfunctions, the sensor must be replaced. Filament wear and contamination are not covered by warranty, and end-user repair voids liability.

Maintenance, Repair; Adjusting the Gauge / p.25

Selection & Integration Q&A

When should I choose the PVG-500 instead of the PVG-502 or an S-suffixed sibling?

Pick the PVG-500 (PVG500KF16) for DN 16 ISO-KF systems needing no relay setpoints and where a tungsten filament is acceptable. Choose PVG-502 for a nickel filament, or an S variant (PVG500KF16S) if you need two adjustable setpoint relays for interlocks or alarms.

What supply and controller interface does the PVG-500 require?

It needs a grounded SELV supply of +14…+30 VDC with ≤1 Vpp ripple, fused at 1 A slow-blow, drawing <500 mA starting current and ≤1 W. The controller input must accept 0…+10.3 VDC and decode the 1.286 V/decade logarithmic signal; gauge identification is 27.0 kΩ on pin 4.

What maintenance and accessories are required, and what is not included?

Allow 10 minutes stabilization after power-up and adjust ATM/HV with a max. ø1.1 mm pin if drift occurs; replace the sensor if contamination is severe. The 8×0.14 mm² shielded sensor cable, clamping ring and centering ring are not included in base delivery and must be ordered separately.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
PVG-500 and PVG-502 Vacuum Gauge User Manual
Manual ·35 pp.
View PDF