Agilent Technologies Yeast Gene Expression Microarray
Agilent Technologies Yeast Gene Expression Microarray — Gene expression microarray platform.
The yeast gene expression microarray workflow is a low-input labeling protocol built around Agilent's One-Color and Two-Color Low Input Quick Amp Labeling kits, accepting 10–200 ng total RNA or as little as 5 ng polyA RNA per reaction. Spike Mix preparation requires a 37 °C, 5-minute heat incubation and 2 µL dispensing per labeling reaction, with four starting-input variants supported. It is used to generate labeled cRNA for hybridization onto custom exon or gene expression microarrays.
Full specifications
| Minimum Pipette Dispensing Volume | 2 µL |
| Poly A Mrna Input | 5 ng |
| Polya Rna Input, Lowest Listed | 5 ng |
| Spike Mix Heat Incubation Time | 5 minutes |
| Spike Mix Volume Per Labeling Reaction | 2 µL |
| Step 1 Time Required | 0.5 hours |
| Total Rna Input, Highest Listed | 200 ng |
| Total Rna Input, Lowest Listed | 10 ng |
| Starting total RNA input variants mfr | four different starting sample inputs inputs |
| Spike Mix first serial dilution mfr | 1 |
| Spike Mix second serial dilution mfr | 1 |
| Spike Mix third serial dilution mfr | 1 |
| Spike mix serial dilution first mfr | 1 |
| Spike mix serial dilution second mfr | 1 |
| Spike mix serial dilution third mfr | 1 |
| Spike mix serial dilution fourth mfr | 1 |
| Spike Mix Heat Incubation Temperature | 37 °C |
Description
Workflow architecture and series positioning
This is the yeast gene expression microarray labeling workflow within Agilent's custom microarray series, which also includes custom exon microarrays and custom gene expression microarrays. The protocol exists in two color formats: One-Color (protocol G4140-90040, v6.9) and Two-Color (G4140-90050, v6.9.1). The two-color variant requires preparation of both Spike A Mix and Spike B, while the one-color variant uses a single Spike Mix. Selection between formats is driven by whether competitive hybridization between two samples is needed.
Input range and labeling behavior
- Total RNA input spans 10 ng (lowest listed) to 200 ng (highest listed) per labeling reaction.
- PolyA RNA input is listed down to 5 ng.
- Four different starting sample inputs are supported, allowing the same protocol to be run across a range of sample availability.
- Spike Mix is added at 2 µL per labeling reaction after a 37 °C, 5-minute heat incubation; serial dilutions of the Spike Mix are prepared in advance (first through fourth dilutions).
Preparation and control specifics
A water bath equilibrated at 37 °C is required for the Spike Mix heat incubation step. The minimum pipette dispensing volume of 2 µL sets the practical lower bound for accurate reagent transfer during Spike Mix and labeling setup. Step 1 (Spike Mix preparation) is listed at 0.5 hours. Data extraction after hybridization is performed with Agilent Feature Extraction Software (Step 2 in both protocol documents).
Integration & Operating Notes
The Spike Mix is heated at 37 °C for 5 minutes before being added at 2 µL per labeling reaction. A water bath equilibrated to 37 °C is specified for this step, so the bath temperature must be verified before starting; deviation in temperature or time affects the spike-in control performance used later by Feature Extraction Software.
Selection & Integration Q&A
Choose this gene expression workflow when the target is transcript-level abundance from 10–200 ng total RNA or 5 ng polyA RNA. The custom exon variant is positioned for exon-level resolution; select it when splice-isoform discrimination is required rather than whole-transcript expression.
A water bath equilibrated to 37 °C, a pipette capable of accurate 2 µL dispensing, the Low Input Quick Amp Labeling kit with Spike Mix, and Agilent Feature Extraction Software for Step 2 data extraction. The One-Color protocol uses one Spike Mix; the Two-Color protocol additionally requires Spike B.
The Spike Mix serial dilutions (first through fourth) are prepared in-house per batch, and the 37 °C water bath and 2 µL-capable pipette are lab-supplied. Feature Extraction Software is required for Step 2 data extraction and is not part of the microarray slide delivery.