Avantik EM8H
Avantik EM8H — Embedding centers.
The Avantik EM8H is the dispensing console module of the EM8 Embedding Center, a benchtop paraffin embedding station with a 5 L reservoir and two 1.7 L side trays. It provides a 12 x 14.75 inch working area held at 50–70 °C for tissue orientation and cassette embedding. It is used upstream of the EM8C cryo console in histology sample preparation workflows.
Full specifications
| Working area | 12 x 14.75 inch |
| Working temperature | 50-70 °C |
| Depth | 17 inch |
| Height | 26 inch |
| Weight | 62 lbs |
| Width | 23.25 inch |
Description
Construction and positioning
- The EM8H is one of two modules in the EM8 Embedding Center; the companion EM8C Cryo Console (0 to −15 °C, 55 lbs) handles cold-plate solidification. - This model is the heated dispensing half: 5 L paraffin reservoir plus left and right trays of 1.7 L each, giving three heated paraffin sources on one benchtop footprint. - Enclosure measures 23.25 in wide x 17 in deep x 26 in high and weighs 62 lbs; the working surface is 12 x 14.75 in. - Reservoir and tray volumes (5 L main, 1.7 L per side tray) set the batch capacity between refills; the documentation gives no melt-down or heat-up time. ### Installation and operation
- Power input is 100–240 V, 50–60 Hz, so the unit runs from standard laboratory mains without a step transformer. - The supplied document digest lists no connection, control, or maintenance sections; only the three electric heated forceps accessories (EQ6109, EQ6110, EQ6111) are identified. Control layout, warm-up procedure, and cleaning instructions must be taken from the full manual before commissioning.
Integration & Operating Notes
The 100–240 V / 50–60 Hz input means the console can be connected to European or North American laboratory circuits directly; confirm the local plug type and circuit rating at installation, since the documentation digest does not state current draw.
The working area is specified only for 50–70 °C. Operating outside this band is not covered by the published specification, and paraffin type should be chosen so its dispensing viscosity is reached inside this window.
The 5 L main reservoir and two 1.7 L side trays define how many cassettes can be processed before replenishment; plan refill breaks accordingly, as no low-level alarm or automatic topping-up feature is described in the available documentation.
Electric heated forceps EQ6109, EQ6110 and EQ6111 are listed as accessories; order them with the console if heated manipulation is required, and obtain cleaning and paraffin-change intervals from the full manual, which is not summarized in the supplied digest.
Selection & Integration Q&A
Pick the EM8H when the task is heated paraffin dispensing and tissue orientation: 5 L reservoir, two 1.7 L trays, 50–70 °C work area. The EM8C is the cold module (0 to −15 °C) for block solidification; most labs need both.
Only a 100–240 V / 50–60 Hz mains outlet and a level bench sized for the 23.25 x 17 in, 62 lb enclosure. Heated forceps (EQ6109–EQ6111) are separate accessories; no controller, drive, or external chiller connection is specified.
The working area is specified for 50–70 °C only, and the documentation digest gives no duty-cycle rating, warm-up time, or ambient temperature range. Keep the unit on a stable bench and confirm continuous-operation suitability with the full manual.
Base delivery covers the console only; electric heated forceps EQ6109, EQ6110 and EQ6111 are optional accessories. Paraffin and cassettes are user-supplied, and the supplied digest lists no service intervals, so follow the full manual for cleaning and reservoir changes.