Avantik QS12
Avantik QS12 — Cryostats.
The Avantik QS12 is a Peltier-assisted cryostat with a −55 °C chamber and four freezing stations, distinguished from the QS12UV sibling by the absence of integrated UV disinfection. It provides stepper-motor sectioning with automated thickness measurement and memory, serving Mohs surgery and histology workflows requiring precise, repeatable frozen sections.
Full specifications
| Chamber temperature | -55 °C |
| Weight | 315 lbs |
Description
Construction and Series Positioning
The QS12 is a floor-standing cryostat (315 lbs / 142.9 kg) built around a −55 °C chamber with 27 total stations, of which four are Peltier freezing stations capable of reaching −55 °C for rapid specimen freezing. Unlike the QS12UV variant, this model does not include the automated UV disinfection option; otherwise, both share the same sectioning architecture. The microtome uses stepper-motor technology with a dovetail clamping knifeholder and an extra-wide anti-roll glass plate to manage section flatness. ### Sectioning Behavior and Control
Section and trim thickness are measured in microns via the EZ-touch touchscreen interface, which also supports a controlled trim function and automated section measurement with memory. The handwheel rotates smoothly, and automatic specimen retraction on the return stroke minimizes compression artifacts. These features allow the operator to set, verify, and reproduce section parameters without manual gauging. Therefore, mounting, electrical supply, and environmental requirements must be confirmed with Avantik directly.
Integration & Operating Notes
The Peltier freezing stations and chamber are rated to −55 °C; operating before thermal stabilization risks incomplete freezing and compromised section quality. Verify chamber temperature via the EZ-touch interface and allow sufficient cool-down after loading specimens.
The EZ-touch touchscreen is the primary interface for section thickness (microns), trim thickness, and the automated measurement/memory function. No separate handwheel micrometer dial is described; operators must use the screen to input and recall parameters.
Selection & Integration Q&A
Choose the QS12 if automated UV disinfection between sessions is not required; it shares the same −55 °C chamber, four Peltier stations, and stepper-motor sectioning. Select the QS12UV when UV decontamination is needed for workflow or safety.
The QS12 uses a dovetail clamping knifeholder and standard cryostat accessories such as OCT compound, cryo-embedding molds, and specimen holders listed in the Avantik Mohs catalog. Confirm holder geometry with Avantik; no proprietary adapter is specified.
The base delivery does not include OCT compound, embedding molds, specimen holders, cryospray, or cleaning reagents; these are separate catalog items. No preventive maintenance interval is stated in the brochures; request the service schedule from Avantik.