Elmo Rietschle C-KLR 80 — Claw Vacuum Pumps with Motor power 4.8 kW, Pumping speed 120 m³/h.

The C-KLR 80 is a dry, contact-free claw vacuum pump with a 4.0/4.8 kW IE3 motor, delivering 94/120 m³/h at 50/60 Hz. As the smaller of two C-KLR series models, it uses G 1 1/4 ports and 0.55 l oil, distinguishing it from the C-KLR 140. It is suited for oil-free evacuation or pressure duty in non-explosive, non-aggressive gas systems.

Motor power
4.8 kW
Pumping speed
120 m³/h

Full specifications

Core Performance & Functional Specifications
Lubrication type dry
Motor power 4.0 kW (50 Hz)
60 Hz: 4.8 kW
Operating principle claw (contact-free, dry compression)
Pumping speed 94 m3/h (50 Hz)
60 Hz: 120 m3/h
Rotational speed 2900 min-1 (50 Hz)
Dimensions, Weight & Mechanical Design
Height 415 mm
Length 791 mm
Weight 136 kg
Width 387 mm
Electrical, Power & Drive Specifications
Power supply 230 / 400 V ± 10 % (50 Hz)
3~: AC
Interfaces, Connections & Control
Inlet flange G 1 1/4
Outlet flange G 1 1/4
Materials, Media & Process Compatibility
Oil capacity 0.55 l
Operating Conditions, Environment & Protection
Noise level 79 dB(A) (50 Hz)
60 Hz: 88 dB(A)
Protection rating IP 55
Cooling type air
Sound pressure level (max.) (alt 50 Hz) mfr 83 dB(A) (50 Hz)

Description

Construction and series positioning

Behavior under load and media

Installation, connection and operation

Integration & Operating Notes

Process Limits
Media must be dry, non-aggressive and non-explosive

The pump is restricted to non-explosive, non-inflammable, non-aggressive and non-poisonous dry gases and gas-air mixtures. Water vapour, liquids, solids, solvents, gaseous oxygen and other oxidants must be excluded; dust per ATEX zone 20–22 is not permitted. Selection must confirm the process gas is compatible to avoid corrosion or hazardous reaction.

Operating Instructions, Sections 2.3 and 2.4, page 7
Mounting
Provide 20 cm cooling clearance and 40 cm filter access

Cooling-air inlets and outlets must be at least 20 cm from adjacent walls to prevent recirculation of heated air. A minimum of 40 cm in front of the inlet filters is required for maintenance access. The foundation and lifting device must be sized for the 136 kg weight.

Operating Instructions, Section 5.1, page 14
Process Limits
Fit a non-return valve if pipes exceed 3 m

When connection pipes of the same cross-section as the machine connection are longer than 3 m, a non-return valve must be installed. This prevents reverse operation when the machine has stopped. Pipe routing must account for this length threshold and the G 1 1/4 port size.

Operating Instructions, Section 5.3, page 15
Electrical
Supply must stay within ±5 % voltage and ±2 % frequency

Without derating, voltage deviation is limited to ±5 % and frequency deviation to ±2 % from the motor data plate. The supply is 3~ 230/400 V ±10 % at 50 Hz, but the tighter ±5 % applies for full performance. A motor protection switch is required, and installation must follow EN 60204 by a qualified electrician.

Operating Instructions, Section 5.6, page 16
Maintenance
Change oil every 5,000 h and check level monthly

Oil must be ISO VG 150 per DIN 51519 (CLP HC 150; e.g. GEARLUBE 150). The oil change interval is every 5,000 operating hours under clean conditions. Check the oil level monthly and fill to the middle of the sight glass. If changing oil type, empty the oil tank completely first.

Operating Instructions, Sections 7.2 and 7.2.1, pages 19–20
Maintenance
Replace filter cartridges every six months

Filter cartridges should be replaced every six months; cleaning by blowing through from the inside out is possible depending on dirt. Insufficient air filter maintenance reduces power and may damage the machine. Coupling sprockets must be checked at least once a year; defective sprockets may lead to rotor shaft breakage.

Operating Instructions, Sections 7.2.2 and 7.2.3, pages 21–22
Process Limits
Limit switching to about 12 times per hour

Frequent switching at about 12 times/h or higher, or elevated ambient/intake temperatures, may exceed motor winding and bearing temperature limits. Contact the manufacturer if the unit is used under such conditions. Ambient and suction temperature must remain between 5 and 40 °C.

Operating Instructions, Section 4.3, page 13
Mounting
Altitude above 1000 m reduces power

At more than 1000 m above sea level a reduction in power is noticeable. Contact the manufacturer for high-altitude installations to confirm suitability or necessary derating.

Operating Instructions, Section 5.2, page 14

Selection & Integration Q&A

When should I choose the C-KLR 80 instead of the C-KLR 140?

Choose the C-KLR 80 for flows up to 94 m³/h at 50 Hz (120 m³/h at 60 Hz) with G 1 1/4 ports. The C-KLR 140 offers higher flow and G 1 1/2 ports but weighs 170 kg. Select the 80 when its capacity and port size match the system, avoiding oversizing.

What are the requirements for piping and a non-return valve when integrating the C-KLR 80?

Pipes must match G 1 1/4. If connection pipes of the same cross-section are longer than 3 m, a non-return valve must be installed to prevent reverse operation after stop. Ensure the valve is compatible with the dry, non-aggressive gas duty.

What ambient and duty-cycle limits apply to the C-KLR 80 installation?

Ambient and suction temperature must be 5–40 °C. Provide 20 cm clearance around cooling-air openings and 40 cm in front of filters. Limit switching to about 12 times/h; higher rates or temperatures may exceed motor limits and require consultation.

What maintenance items and consumables are required for the C-KLR 80, and what is not included in base delivery?

Plan for oil changes every 5,000 h using ISO VG 150 oil (0.55 l), filter cartridge replacement every 6 months, and annual coupling sprocket inspection. Oil, filters, and coupling sprockets are not included in base delivery and must be ordered separately.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Operating Instructions — C-KLR 80 vacuum pump (BA 883-EN, ed. 1.0 22.6.2017, EN)
Manual ·3,1 МБ ·28 pp.
View PDF
PDF
Technical Data Sheet — C-KLR 80 IE3 vacuum pump DE/EN)
Datasheet ·592,1 КБ ·3 pp.
View PDF
PDF
Spare Parts List — C-KLR 80 (E 883, EN)
Spare parts ·772,9 КБ ·4 pp.
View PDF